Page 431
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-45 delrsub 13 Errors If either the name or extension doesn’t b elong to a valid voic e mail system remote sub sc rib er, an error messag e d isp lays. If more rec ord s exist, sub sc rib er d eletion c ontinues. Input Format The Inp ut Format c onsists of one rec ord for eac h sub sc rib er, formatted as follows: Output Format The Outp ut Format for eac h rec ord c...
Page 432
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-46 delsub 13 delsub Delete subscrib er Syntax delsub [-r release] [-v ] [-w ] [-V ] [-i ] [< ifile] [> ofile] Description This c ommand d eletes sub sc rib ers from the c urrent d atab ase of the voic e mail system. Use the name and extension as inp ut for eac h sub sc rib er. Command statistic s are written to stand ard outp ut. -r Release flag ; must b e...
Page 433
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-47 delsub 13 Errors If either the name or extension d oesn’t b elong to a valid system subsc riber, an error message d isp lays. If more rec ord s exist, sub sc rib er d eletion c ontinues. Input Format The Inp ut Format c onsists of one rec ord for eac h sub sc rib er, formatted as follows. When c onnec ted to an AUDIX system, only as many c harac ters are req uired...
Page 434
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-48 setadj 13 setadj Set mac hine translation adjunc t d ata Syntax setadj -m mac hine name [-p p assword] [-t mac hine_typ e] [-n network_c onnec tion_typ e] [-s d ata_rate] [-c c hannel] [-d d ial_string] [-q purg e_q ueue] [-N new_mac hine_name] -r release [-a | -u ] [-v ] [-w ] [-V ] Description This c ommand sets the field values for the following sc...
Page 435
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-49 setadj 13 Errors Using this c ommand with an INTUITY or DEFINITY AUDIX System or an R1 AUDIX System p rior to R1V5, an error messag e d isp lays. -c Channel flag ; must be followed b y c hannel. c hannelSets the c hannel for the sp ec ified mac hine. Valid c hannels are null (b lank), 5 or 6 for rs232, or null for d c p . -d Dial string flag ; must b e...
Page 436
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-50 setadj 13 Example The following command changes the baud rate for the new york mac hine on the system : translation : mac hine : ad junc t sc reen and writes a summary of the transfer statistic s to the sc reen. setadj -m new york -s 4800 -r r1v8 -v The following c ommand ad d s a mac hine named seattle on the system : translation : mac hine : ad junc t sc reen,...
Page 437
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-51 setalogp 13 setalogp Set ac tivity log p arameters Syntax setalogp [-a y/n] [-M y/n] [-N nnnn] [-c y/n] [-r release] [-v ] [-w ] [-V ] Description This c ommand sets the field values for the following sc reens. nINTUITY AUDIX Chang e System-Parameters Ac tivity-Log nDEFINITY AUDIX Chang e System-Parameters Ac tivity-Logsn. -a Ac tivity log flag ; must be...
Page 438
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-52 setalogp 13 Errors If you use this c ommand with an R1 AUDIX System, an error messag e ap p ears. Example The following c ommand sets the field values of the Chang e System-Parameters Ac tivity-Log sc reen d ata and writes a summary of the transfer statistic s to the sc reen: setalogp -a y -N 500 -v RETU RN
Page 439
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-53 setscdr 13 setscdr Set Call Detail Rec ord ing d ata Syntax setscdr [-n nnnnnn] [-a y/n] [-s y/n] [-o y/n] [-N y/n] -r release [-v ] [-w ] [-V ] Description This c ommand sets the field values on the system : c d r sc reen for the op tions you sp ec ify on the c ommand line. You c an use the setscdr c ommand with the R1 AUDIX System (R1V5 and beyond .) No inp...
Page 440
AUDIX Administration and Data Acquisition Package 585-302-502 Issue 14 May 1999 Command Line Database Modification Commands 13-54 setscdr 13 Errors If you use this c ommand with an INTUITY or DEFINITY AUDIX System or an R1 AUDIX System p rior to R1V5, an error messag e d isp lays. Example The following c ommand sets the system : c d r sc reen d ata and writes a summary of the transfer statistic s to the sc reen. setscdr -a y -s y -o n -N n -r r1v8 -v -w Writes a one-line summary of the...