Page 31
✽The fan motor at the freezing room does not stop but operates if opening doors of the freezing room or cold storage room or the home bar during operation of the fan motor at the freezing room. ✽(A), (B), (C) and (D) of door switch for the freezing room or cold storage room are connected to the door open sensing circuit toward both ends of switch to determine door open at MICOM. ✽Since a door switch of the home bar is connected to door switch (C), (D) of the cold storage room, it senses door opening if...
Page 32
EXPLATION FOR MICOM CIRCUIT - 32 - ASSEMBLY Measuring part (IC6) No.16 No.11 No.12 No.15 No.14 StatusON Within 1 V OFF 12 V Type of Load COMPFrost Removal HeaterAC Converting RelayR-room LAMPHomebar Heater
Page 34
1) Check load driving status 2) Lever S/W sensing circuit EXPLATION FOR MICOM CIRCUIT - 34 - Measuring part Lever S/WIC1(Micom) No.15 (16) On(Press) OFF 5V 0 V(60 Hz) 5 V Measuring part IC7-No.16 IC7-No.15 IC7-No.14 IC7-No.13 IC7-No.12 IC7-No.11 IC7-No.10 StatusON Within 1 V OFF 12 V Type of LoadGEARED MOTORSOLENOID CUBEWATER VALVE ICE WATERPILOT VA LV ESOLENOID DISPENSERHOME BAR HEATER
Page 36
✽Since door switch sensing switch (A), (B) are a separate switch even if the door switch of the freezing room normally operates, they may fail to sense door opening in the failure of switch at both ends of (A) and (B) or in failure of the L/wire. ✽Lamp does at the cold storage room not turn on if the door switch of the cold storage room fails to sense the door open switch (c ), (d) or the home bar switch. EXPLATION FOR MICOM CIRCUIT - 36 - Closing 5 V ( A - B , C - D, E - F . S/W at both ends...
Page 38
The above circuits are circuits attached to freezing room sensor or cold storage room sensor for adjusting setting temperature at the freezing room and cold storage room, ice-making sensor for sensing water temperature in ice-making, or an evaporator for sensing temperature of a frost removal sensor necessary for frost removal. Short or open status of every temperature sensor is as follows: SENSOR CHECK POINTNORMAL(-30 °C ~ 50 °C) IN SHORT IN OPEN Freezing sensor POINT A Voltage Frost removal sensor...
Page 40
The above circuits are circuits attached to freezing room sensor or cold storage room sensor for adjusting setting temperature at the freezing room and cold storage room, ice-making sensor for sensing water temperature in ice-making, or an evaporator for sensing temperature of a frost removal sensor necessary for frost removal. Short or open status of every temperature sensor is as follows: A E B D C SENSOR CHECK POINTNORMAL(-30 °C ~ 50 °C) IN SHORT IN OPEN Freezing sensor POINT A Voltage Frost...