LG Gr P227 Ytqa Service Manual
Here you can view all the pages of manual LG Gr P227 Ytqa Service Manual. The LG manuals for Fridge freezer are available online for free. You can easily download all the documents as PDF.
Page 71
3. Ice Maker Troubleshooting * Troubleshooting:it is possible to confirm by pressing freezer and refrigerator temperature control buttons for more than 1 second. (ice maker is normal if all leds are on): refer to trouble diagnposis function in MICOM function 2-8 (page 18) ICE MAKER AND DISPENSER WORKING PRINCIPLES AND REPAIR - 71 - No Yes Yes Yes No No No No Yes YesIs DC Power (5V and 12V) output normal?Failed DC Power • Check DC power (5V, 12V).Change main PWB Is cube ice led off during...
Page 72
- 72 - ICE MAKER AND DISPENSER WORKING PRINCIPLES AND REPAIR No Yes Yes Yes No No No No Yes YesIs DC Power (5V and 12V) output normal?Failed DC Power • Check DC power (5V, 12V).Change main PWB Is cube ice led off during troubleshooting check?Failed ice making sensor • Check the resistance of both ends (1,2) of ice making sensor of CON8. • Defects between ice making sensor and board (Pin No. 59 of IC1)Replace Ice making Sensor Is Crushed Ice LED off during troubleshooting check?Failed Ice Maker...
Page 75
1. TROUBLE SHOOTING TROUBLE DIAGNOSIS - 75 - CLAIMS. CAUSES AND CHECK POINTS. HOW TO CHECK 1. Faulty start 1) No power on outlet. 2) No power on cord. 3) Shorted start circuit. 4) During defrost.* Measuring instrument : Multi tester Check the voltage. If the voltage is within ±85% of the rated voltage, it is OK. Check the terminal movement. Check both terminals of power cord. Power conducts : OK. No power conducts : NG Check both terminals of O.L.P. If power conducts : OK. If not : NG. Check...
Page 76
TROUBLE DIAGNOSIS - 76 - CLAIMS. CAUSES AND CHECK POINTS. HOW TO CHECK 2. No cooling. 2) Refrigeration system is clogged.Check the clogged evaporator by heating (as soon as the cracking sound begins, the evaporator start freezing) The evaporator does not cool from the beginnig (no evidece of misture attached). The evaporator is the same as before even heat is applied. Moisture clogged. No electric power on therm- ostat. Weld joint clogged. Drier cloggeing. Foreign material clogging.Residual moisture...
Page 77
TROUBLE DIAGNOSIS - 77 - CLAIMS. CAUSES AND CHECK POINTS. HOW TO CHECK 3. Refrigeration is weak. Heater Sheath 1) Refrigerant Partly leaked. 2) Poor defrosting capacity. Drain path (pipe) clogged. Defrost heater does not generate heat. Weld joint leak. Parts leak. Inject P/U into drain hose. Foreign materials penetration. Cap drain is not disconnected.Inject through the hole. Seal with drain. P/U lump input. Screw input. Other foreign materials input. Parts disconnected.Wire is cut. - Lead wire. -...
Page 78
- 78 - TROUBLE DIAGNOSIS CLAIMS. CAUSES AND CHECK POINTS. HOW TO CHECK 3. Refrigeration is weak. 3) Cooling air leak. 4) No cooling air circulation. Residual frost. No automatic defrosting. Defrost does not return. Bad gasket adhestion Door sag. Faulty fan motor.Weak heat from heater. Too short defrosting time. Defrost Sensor. - Faulty characteristics. Seat-D(missing, location. thickness). Structural fault. Gasket gap. Air inflow through the fan motor. Bad insulation of case door.Sheath Heater - rated....
Page 79
TROUBLE DIAGNOSIS - 79 - CLAIMS. CAUSES AND CHECK POINTS. HOW TO CHECK 3. Refrigeration is weak. 4) No cooling air circulation. 5) Compressor capacity. 6) Refrigerant too much or too little. 7) Continuous operation - No contact of temperature controller. - Foreign materials. 8) Damper opens continuously. Foreign materials jammed. Failed sensor. - Position of sensor. Characteristics of damper. 9) Food storing place. - Near the outlet of cooling air. Faulty fan motor. Small cooling air discharge.Fan...
Page 80
TROUBLE DIAGNOSIS - 80 - CLAIMS. CAUSES AND CHECK POINTS. HOW TO CHECK 4. Warm refrigerator compartment temperature. 5. No automatic operation. (faulty contacts.) 6. Dew and ice formation. 1) Colgged cooling path. 2) Food storate. 1) Faulty temperature sensor in freezer or refrigerator compartment. 2) Refrigeration load is too much. 3) Poor insulation. 4) Bad radiation. 5) Refrigerant leak. 6) Inadequate of refrigerant. 7) Weak compressor discharging power. 8) Fan does not work. 9) Button is positioned...