    							✽The fan motor at the freezing room does not stop but operates if opening doors of the freezing room or cold storage room
    or the home bar during operation of the fan motor at the freezing room.
    ✽(A), (B), (C) and (D) of door switch for the freezing room or cold storage room are connected to the door open sensing
    circuit toward both ends of switch to determine door open at MICOM.
    ✽Since a door switch of the home bar is connected to door switch (C), (D) of the cold storage room, it senses door opening
    if even one of both is opened.
    EXPLATION FOR MICOM CIRCUIT 
    - 31 -
    
    P.T.C       ASSEMBLY COMP
    Measuring part (IC6) No.16 No.11 No.10 No.15 No.14
    StatusON Within 1 V
    OFF 12 V
    Type of Load COMPFrost Removal
    HeaterAC Converting
    RelayR-room LAMPHomebar
    Heater
     
    						
    							EXPLATION FOR MICOM CIRCUIT 
    - 32 -
    
    ASSEMBLY
    Measuring part (IC6) No.16 No.11 No.12 No.15 No.14
    StatusON Within 1 V
    OFF 12 V
    Type of Load COMPFrost Removal
    HeaterAC Converting
    RelayR-room LAMPHomebar
    Heater
     
    						
    							2. Dispenser operation circuit
    EXPLATION FOR MICOM CIRCUIT 
    - 33 -
    
    
     
    						
    							1) Check load driving status 
    2) Lever S/W sensing circuit
    EXPLATION FOR MICOM CIRCUIT 
    - 34 -
    Measuring part
    Lever S/WIC1(Micom) No.15 (16)
    On(Press)
    OFF 5V
    0 V(60 Hz) 5 V
    Measuring part IC7-No.16 IC7-No.15 IC7-No.14 IC7-No.13 IC7-No.12 IC7-No.11 IC7-No.10
    StatusON Within 1 V
    OFF 12 V
    Type of LoadGEARED
    MOTORSOLENOID
    CUBEWATER VALVE
    ICE WATERPILOT
    VA LV ESOLENOID
    DISPENSERHOME BAR
    HEATER
     
    						
    							3. Door opening sensing circuit
    EXPLATION FOR MICOM CIRCUIT 
    - 35 -
    
    
    
    
     
    						
    							✽Since door switch sensing switch (A), (B) are a separate switch even if the door switch of the freezing room normally
    operates, they may fail to sense door opening in the failure of switch at both ends of (A) and (B) or in failure of the L/wire. 
    ✽Lamp does at the cold storage room not turn on if the door switch of the cold storage room fails to sense the door open
    switch (c ), (d) or the home bar switch.
    EXPLATION FOR MICOM CIRCUIT 
    - 36 -
    Closing 5 V ( A  -  B ,  C  -  D,  E  -  F  . S/W at both ends are at Off status)
    Opening 5 V ( A  -  B ,  C  -  D,  E  -  F  . S/W at both ends are at On status)
    Measuring part
    IC1 (MICOM) No. 47, 46 Pin
    Door of Freezing/Cold Storage Room
    CONDITIONS
    Bell sounds when button on  Beep sounds when warning
    MEASURING dosplay is pressed. door opening.OFF
    POINTS
    IC1 (No. 48 Pin)5 V
    IC1 (No. 51 Pin)0 V
    0.05 s
    2.63 kz (DING)2.63 kz (BEEP)OFF 2.21 kz (DONG)
    0.2 s 0.1 s 0.4 s 0.5 s 0.5 s
    5 V
    0 V
    5 V
    0 V5 V
    0 V
    5 V
    0 V
     
    						
    							1-5. Temperature sensing circuit
    EXPLATION FOR MICOM CIRCUIT 
    - 37 -
    
    
     
    						
    							The above circuits are circuits attached to freezing room sensor or cold storage room sensor for adjusting setting
    temperature at the freezing room and cold storage room, ice-making sensor for sensing water temperature in ice-making, or
    an evaporator for sensing temperature of a frost removal sensor necessary for frost removal. Short or open status of every
    temperature sensor is as follows:
    SENSOR CHECK POINTNORMAL(-30 °C ~ 50 °C) IN SHORT IN OPEN
    Freezing sensor POINT  A  Voltage
    Frost removal sensor POINT  B  Voltage
    Cold storage sensor 1 POINT  C  Voltage
    0.5 V~4.5 V 0 V 5 V
    Cold storage sensor 2 POINT  D  Voltage
    Ice making sensor POINT  E  Voltage
    Room temperature sensor POINT  F  Voltage
    EXPLATION FOR MICOM CIRCUIT 
    - 38 -
     
    						
    							EXPLATION FOR MICOM CIRCUIT 
    - 39 -
    
    E
    A
    B
    C
    D
     
    						
    							The above circuits are circuits attached to freezing room sensor or cold storage room sensor for adjusting setting
    temperature at the freezing room and cold storage room, ice-making sensor for sensing water temperature in ice-making, or
    an evaporator for sensing temperature of a frost removal sensor necessary for frost removal. Short or open status of every
    temperature sensor is as follows:
    
    A
    E
    B
    D
    C
    SENSOR CHECK POINTNORMAL(-30 °C ~ 50 °C) IN SHORT IN OPEN
    Freezing sensor POINT  A  Voltage
    Frost removal sensor POINT  B  Voltage
    Cold storage sensor 1 POINT  C  Voltage 0.5 V~4.5 V 0 V 5 V
    Cold storage sensor 2 POINT  D  Voltage
    Room temperature sensor POINT  E  Voltage
    EXPLATION FOR MICOM CIRCUIT 