Page 141
Diagnostic Aids3-8 4059-XXX Error Log Viewing the Error Log The error log is helpful to the servicer by providing a history of printer errors. The error log contains the 12 most recent errors that have occurred on the printer. The most recent error displays in position 1 and the oldest error displays in position 12 (if 12 errors have occurred). If an error occurs after the log is full, the oldest error is discarded. Identical errors in consecutive positions in the log are entered. All 2xx and 9xx error...
Page 142
3-94059 Service Manual 4059-XXX Hardware Tests The following Hardware Tests can be selected from this menu: LCD Test Button Test DRAM Memory Test ROM Memory Test Parallel Wrap (if available) Serial Wrap (if available) Serial1Wrap(ifavailable) Serial3Wrap(ifavailable) LCD Test To run the LCD Test: 1. Select LCD Test from the Diagnostic menu. – The LCD test continually executes the LCD display test. 2. Press Return/Stop to cancel the test. Button Test To run the Button Test: 1. Select Button Test from the...
Page 143
Diagnostic Aids3-10 4059-XXX DRAM Memory Test The purpose of this test is to check the validity of DRAM, both standard and optional. The test writes patterns of data to DRAM to verify that each bit in memory can be set and read correctly. To run the DRAM Memory Test: 1. Select DRAM Memory Test from the menu. – The power indicator blinks indicating the test is in progress. 2. Press Return/Stop to exit the test. P:###### represents the number of times the memory test has passed and finished successfully....
Page 144
3-114059 Service Manual 4059-XXX Each time the test finishes, the screen updates with the result. If the test passes, the Pass Count increases by 1, however if the test fails, one of the following messages displays for approximately 3 seconds: ROM Checksum Error ROM Burst Read Error Once the maximum pass count or fail count is reached, the test stops with the power indicator on solid. The final results display on the screen. Parallel Wrap Test This test is used with a wrap plug to check operation of the...
Page 145
Diagnostic Aids3-12 4059-XXX DMA Interrupt Error DMA Memory Error DMA Background Error Clear Init Rise Error False Init Rise Error Autofeed Rising Interrupt Error Clear Autofeed Rise Error False Autofeed Rise Error Autofeed Falling Interrupt Error Clear Autofeed Fall Error Once the maximum count is reached the test stops. The power indicator goes on solid and the final results display. Press Return/Stop to exit the test. Serial Wrap Test This test is used to check the operation of the Serial Port...
Page 146
3-134059 Service Manual 4059-XXX Each time the test finishes, the screen updates with the result. If the test passes, the Pass Count increases by 1, however if the test fails, one of the following failure messages displays for approximately 3 seconds and the Fail Count increases by 1: Receive Status Interrupt Error Status Error Receive Data Interrupt Error Transmit Data Interrupt Error Transmit Empty Error Threshold Error Receive Data Ready Error Break Interrupt Error Framing Error Par ity Error Overrun...
Page 147
Diagnostic Aids3-14 4059-XXX Input Tray Tests Input Tray Feed Test This test lets the servicer observe the paper path as media is feeding through the printer. A blank sheet of paper feeds through the printer as the laser turns off during this test. The only way to observe the paper path is to open the lower front door that is used to access the envelope or multipurpose feeder. The paper is placed in the output bin. To run the Input Tray Feed Test: 1. Select Input Tray Feed Test from the menu. 2. Select...
Page 148
3-154059 Service Manual 4059-XXX The multipurpose tray and the envelope feeder do not have a paper low sensor. The multipurpose tray does not have a pass thru sensor. OutputBinTest-StandardBin This test is used to verify if the standard bin sensor is working correctly. To run the Standard Bin Sensor Test: 1. Select Output Bin Tests from the Diagnostic Menu. 2. Select Output Bin Tests - Sensor Tests. 3. Select Sensor Tests - Standard Bin. – “Standard Bin/Full=CL” message displays. Manually actuate the bin...
Page 149
Diagnostic Aids3-16 4059-XXX Output Bin Sensor Test This test is used to verify if the output bin sensors are working correctly. To run the Output Bin Sensor Test: 1. Select Sensor Test from the Output Bin Test menu. – Output Bin/Full=OP/Input=OP message displays. – Full = Output Bins Full Sensor – Pass = Output Bins Pass Thru Sensor 2. Once the message displays, the servicer can manually actuate each of the output bin sensors. The bin full sensor can be actuated by hand, however a sheet of paper can be...
Page 150
3-174059 Service Manual 4059-XXX Output Expander with Dual Sensor: The following is displayed: Output Bin X P=OP F=OP NF=CL P = Pass Thru Sensor F = BIN FULL Sensor (lower part of dual sensor) NF = Near Full Sensor (upper part of dual sensor) Once the message displays, the servicer can manually actuate each of the output bin sensors. The bin full sensor can also be actuated by hand. Use a sheet of paper to cover the bins pass thru sensor. When the sensor is closed CL displays, and when the sensor is open...