Page 581
Repair information 4-147 5058-030 Go Back Previous Next 7.Remove the two screws (A). 8.Disconnect the cable (B). 9.Remove the registration/transport roller assembly. RIP PCBA removal Before you replace the RIP PCBA, make sure you back up the eSF solutions and settings. See “eSF solutions backup” on page 4-149. Warning: If you are replacing the RIP PCBA in addition to the operator panel or the operator panel PCBA, you must replace one component at a time. After you replace one component, perform a...
Page 582
4-148 Service Manual 5058-030 Go Back Previous Next device before replacing a second component. If you replace the components simultaneously, the printer will be rendered inoperable. 1.Remove the two screws (A) securing the RIP PCBA to the machine.
Page 583
Repair information 4-149 5058-030 Go Back Previous Next 2.Remove the RIP PCBA. eSF solutions backup If a technician needs to replace the RIP PCBA, the steps below should be taken to back up the eSF solutions and settings: 1.POR the printer into invalid engine code mode. 2.Open a Web browser and navigate to the printer’s Web page. 3.Navigate to Settings, and click the link. 4.Navigate to Solutions and click the link. 5.Navigate to Embedded Solutions and click the link. 6.On the Embedded Solutions...
Page 584
4-150 Service Manual 5058-030 Go Back Previous Next number of applications or settings may exceed the file size limit and have information truncated in the exported file. Sensor (image calibration) removal 1.Remove the printer front door. See “Printer front door removal” on page 4-10. 2.Remove the transfer belt cleaner. See “Transfer belt cleaner removal” on page 4-175. 3.Remove the waste toner box. 4.Remove the four photoconductor units. 5.Remove the four toner supplies. 6.Remove the operator panel...
Page 585
Repair information 4-151 5058-030 Go Back Previous Next 14.Gently slide the sensor (image calibration) out and remove it. Sensor (media level) removal 1.Remove the appropriate feeder unit. See “Printer tray 1 feeder removal” on page 4-141, “Tray module media feeder removal” on page 4-212, “TTM tray 4 media feeder removal” on page 4-225, or “TTM tray 3 feeder removal” on page 4-221. 2.Release the tabs (A) securing the sensor (media level) to the assembly.
Page 586
4-152 Service Manual 5058-030 Go Back Previous Next 3.Remove the sensor (media level). 4.Disconnect the harness (B). Sensor (media on belt) removal 1.Open the printer left duplex door assembly. 2.Remove the screw (A) securing the sensor (media on belt) to the machine.
Page 587
Repair information 4-153 5058-030 Go Back Previous Next 3.Disconnect the cable (B). 4.Remove the sensor (media on belt). Sensor (media out) removal 1.Remove the appropriate feeder unit. See “Printer tray 1 feeder removal” on page 4-141, “Tray module media feeder removal” on page 4-212, “TTM tray 4 media feeder removal” on page 4-225, or “TTM tray 3 feeder removal” on page 4-221. 2.Remove the media out actuator. See “Media out actuator removal” on page 4-120. 3.Release the tab (A) securing the sensor...
Page 588
4-154 Service Manual 5058-030 Go Back Previous Next 4.Remove the sensor (media out). 5.Disconnect the cable (B).
Page 589
Repair information 4-155 5058-030 Go Back Previous Next Sensor (printer left duplex door interlock) removal 1.Remove the rear upper cover. See “Rear upper cover removal” on page 4-16. 2.Disconnect the input option cable (A). 3.Remove the eight screws (B) securing the PCBA door to the machine.
Page 590
4-156 Service Manual 5058-030 Go Back Previous Next 4.Release the two clamps (C) to release the harness. 5.Swing the PCBA door open. 6.Remove the screw (D) securing the bracket to the machine. 7.Remove the bracket.