Page 261
R e p a ir in fo rm a tio n4-15 5026 Go Back Previous Next 7.Select Quick Test in the Cyan menu, and press . Two pages print. You may have to print these pages several times until you get T (Top Margin) and Z (Skew) aligned. Do not go to step 2 until T and Z are aligned. The first page is similar to the following:
Page 262
4-16Service Manual 5026 Go Back Previous Next 8.Determine the line under Fine Adjustment that is closest. If the value is beyond the Fine Adjustment scale, use either of the Coarse Adjustment scales. 9.Enter the number determined from the Fine Adjustment scale or the Coarse Adjustment scales on the part of the page for the “T” value. The current value is automatically entered on the sheet. At this point, it should be zero. 10.Enter the “New Cyan T value” on the operator panel using the left and right...
Page 263
Repair information4-17 5026 Go Back Previous Next 12.Repeat this process for skew (Z). Dont forget to subtract the T value and add the current cyan Z value to obtain the new skew (Z) value. An example is shown below: 13.Continue to follow the directions on the bottom of the first page to find the Cyan Top Margin (T), the Skew (Z), and on the second page of the Quick Test page, the Left Margin (L), Right Margin (R), and Bow (P). 14.Repeat steps 1 through 13 for yellow and magenta. Note: Start each...
Page 264
4-18Service Manual 5026 Go Back Previous Next Printhead mechanical alignment (C748) Skew (black) 1.Turn off the printer. 2.Disconnect the power cord from the electrical outlet. 3.Remove the transfer module and photoconductor units: a.Disconnect the transfer module cable (A). b.Press the two tabs (B) to release the front access cover assembly. c.Press the two tabs (C) on either side of the transfer module, and lift out the transfer module. Note: Leave the photoconductor units on the transport belt when...
Page 265
Repair information4-19 5026 Go Back Previous Next 5.Remove the printhead alignment screw cover (E). 6.Reinstall the transfer module with the photoconductor units still attached. 7.Reconnect the transfer module cable. 8.Replace the toner cartridges. 9.Close the top access door. 10.Close the front access door. 11.Plug the electrical cord into the printer. 12.Plug the electrical cord into the outlet. 13.Align the printhead skew for black. a.Enter the Diagnostic menu (turn off the printer, press and...
Page 266
4-20Service Manual 5026 Go Back Previous Next e.Scroll down and touch Quick Test. A page similar to this one prints:
Page 267
Repair information4-21 5026 Go Back Previous Next f.Adjust the printhead alignment screw (G) to change the skew and straighten the image on the printout. If the top right alignment marks are lower than the top left alignment marks, rotate the alignment screw counterclockwise a full revolution, and print the Quick Test page. Repeat adjusting the screw and printing the Quick Test until the top alignment marks are the same distance from the top of the media. Note: One rotation of the printhead...
Page 268
4-22Service Manual 5026 Go Back Previous Next 14.Tighten the printhead mounting screws. a.Turn off the printer. b.Disconnect the power cord from the electrical outlet. c.Disconnect the transfer module cable. d.Press the two tabs on either side of the transfer module, and lift out the transfer module with the photoconductor units in place. e.Remove all of the toner cartridges. f.Tighten the printhead mounting screws in the following order: H1, H2, and H3. 15.Replace the printhead alignment screw...
Page 269
Repair information4-23 5026 Go Back Previous Next Registration (black) Top Margin 1.Reconnect the power cord to the electrical outlet, but do not turn on the printer yet. 2.Enter Diagnostic mode (press and hold buttons 3 and 6, turn on the printer, and release the buttons when the clock graphic displays). 3.Touch REGISTRATION. 4.Touch Quick Test or use the last Quick Test you used to adjust skew. 5.Touch Top Margin. 6.Adjust the values until both top alignment marks are on the top edge of the print....
Page 270
4-24Service Manual 5026 Go Back Previous Next Left Margin 1.Touch Left Margin. 2.Adjust the left margin until the points of the left alignment marks touch the edge of the page. •Increasing the value (+) moves the left alignment marks away from the edge of the page. •Decreasing the value (-) moves the left alignment marks toward the edge of the page. 3.Touch to save the value. 4.Print the Quick Test page, and check the left alignment marks each time until you are satisfied. Right Margin 1.Touch Right...