Home > Kenmore > Water Heater > Kenmore Economizer 6 Manual

Kenmore Economizer 6 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Kenmore Economizer 6 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 23 Kenmore manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    21
    
    FIGURE 32.
    Use this guide to check a “Leaking” water heater. Many suspected 
    “Leakers”  are  not  leaking  tanks.  Often  the  source  of  the  water 
    can be found and corrected.
    If you are not thoroughly familiar with electric codes, the water 
    heater,  and  safety  practices,  contact  your  local  Sears  Service 
    Center to check the water heater.
    LEAKAGE CHECKPOINTS
    Read this manual first. Then before checking the water heater make  sure  the  electric  supply  has  been  turned  “OFF”,  and never turn the electric supply “on” before the tank is completely 
    full of water.
    Never use this water heater unless it is completely full of water. To  prevent  damage  to  the  tank  and  heating  element,  the  tank must be filled with water. The water must flow from the hot water faucet before turning “ON” power.
    A. *Condensation  may  be  seen  on  pipes  in  humid  weather  or 
    pipe connections may be leaking.
    B.  Small amounts of water from the temperature-pressure relief 
    valve may be due to thermal expansion or high water pressure in your area.
    C.  *The temperature-pressure relief valve may be leaking at the 
    tank fitting.
    D.  The element may be leaking at the tank fitting.
    E.  The element may be leaking at the tank fitting.
    F.  *The drain valve may be leaking at the tank fitting.
    G.  Water  in  the  water  heater  bottom  or  on  the  floor  may  be 
    from  condensation,  loose  connections  or  the  temperature-pressure relief valve. DO NOT replace the water heater until a  full  inspection  of  all  possible  water  sources  is  made  and necessary corrective steps taken.
    H.  Check anode rod fitting for leak.
    Note:  Models  with  optional  fitting  locations  on  top,  check for leaks at plugs.
    Leakage from other appliances, water lines, or ground seepage should also be checked.
    Note: To check where threaded portion enters tank, insert cotton  swab  between  jacket  opening  and  fitting.  If  cotton is  wet,  follow  “Draining”  instructions  in  the  “Service  and Maintenance”  section  and  then  remove  fitting.  Put  pipe dope or teflon tape on the threads and replace. Then follow “Filling  the  Water  Heater”  instructions  in  the  “Installation 
    Instructions” section. 
    						
    							
    22
    
    Now that you have purchased this water heater, should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit.
    All Parts listed may be ordered from any Sears Service Center and by calling 1-800-366-PART (1-800-366-7278).
    If the parts you need are not stocked locally, your order will be electronically  transmitted  to  a  Sears  Repair  Parts  Distribution Center for handling.
    The model number of the water heater will be found on the model rating plate located near the access panel.
    WHEN  ORDERING  REPAIR  PARTS,  ALWAYS  GIVE  THE FOLLOWING INFORMATION:
    • Model Number  •  Part Number 
    •  Serial Number 
    •  Part Description
    THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.
    ** Also available at most hardware stores. † Replaced only on return of damaged plate. # Not illustrated.
    KENMORE THE ECONOMIZERTM 6
    COMPACT ELECTRIC WATER HEATERS
    REPAIR PARTS LIST
    MODEL NO’S
     153.316040  6 Gallon
      153.316050  10 Gallon
      153.316060  19 Gallon Short
      153.316070  19.9 Gallon Tall
      153.326060  19 Gallon 240 V. Short
      153.326070  19.9 Gallon 240 V Tall
    Note:  Illustration  is  used  to  reference  parts  of  compact models  only  -  Actual  locations  of  components  on  water heater may vary from model to model.
    61019 (20S)19.9 (20T)19 (20S)19.9 (20T)
    Description153.316040153.316050153.316060153.316070153.326060153.326070
      1. Access Door900629390062939006293900629390062939006293
      2. Drain Valve900005890000589000058900005890000589000058
      3. Drain Valve Washer
          17/32”x13/64”x1/8 Tk
    900158490015849001584900158490015849001584
      4. Element900013990001399000139900013990001339000133
      5. Element Gasket900030890003089000308900030890003089000308
      6. Inlet Nipple - 2-1/2”900397690039769003976900397690039769003976
      7. Junction Box Cover900132790013279001327900132790013279001327
      8. Manual # 85775-00085775-00085775-00085775-00085775-00085775-000
      9. Model Rating Plate +184227-000184227-000184227-000184227-000184227-000184227-000
    10. ON/OFF Switch9000340900034090003409000340--------------------
    11. Outlet Nipple900149490014949006294900149490062949001494
    12. Temperature-Pressure
          Relief Valve - 2”
    900072890007289000728900072890007289000728
    13. Terminal Cover900243890024389002438900243890024389002438
    14. Thermostat Bracket900629890062989006298900629890062989006298
    15. T’stat W/Hi Limit900232790023279002327900232790023279002327
    16. Anode Rod900394290039429003944900394490039449003944
    17. Inlet Tube9006297---------9006296900366390062969003663
    18. Plug900143790014379001437900143790014379001437 
    						
    							
    23
    
     Key    Model Numbers     
      No.  Part Description  153.316331 153.326331
      1  Access Panel  9003900 9003900
      2  Anode Rod  9003944 9003944
      3  Drain Valve  9000058 9000058
      4  Drain Valve Washer (17/32” x 13/64” x 1/8” Thick)**  9001584 9001584
      5  Element  9000139 9000133
      6  Element Gasket  9000308 9000308
      7  Element Insulation Cap  9003723 9003723
      8  Inlet Water Nipple  9002298 9002298
      9  Junction Box Cover  9001327 9001327
      10  Manual#  185775-000 185775-000
      11  Model Rating Plate†  184227-001 184227-000
      12  ON/OFF Switch  9000340 ------
      13  Outlet Nipple  9001494 9001494
      14  Temperature-Pressure Relief Valve  9000728 9000728
      15  Terminal Cover  9002438 9002438
      16  Thermostat Bracket  9006295 9006295
      17  Thermostat w/4 Terminal Hi Limit  9002327 9002327
    Now that you have purchased this water heater, should a need 
    ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit.
    All Parts listed may be ordered from any Sears Service Center and by calling 1-800-366-PART (1-800-366-7278).
    If the parts you need are not stocked locally, your order will be electronically  transmitted  to  a  Sears  Repair  Parts  Distribution Center for handling.
    The model number of the water heater will be found on the model 
    rating plate located near the access panel.
    WHEN  ORDERING  REPAIR  PARTS,  ALWAYS  GIVE  THE FOLLOWING INFORMATION:
    • Model Number  •  Part Number 
    •  Serial Number 
    •  Part Description
    THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.
    ** Also available at most hardware stores. † Replaced only on return of damaged plate. # Not illustrated.
    KENMORE THE ECONOMIZERTM 6
    COMPACT ELECTRIC WATER HEATERS
    REPAIR PARTS LIST
    MODEL NO’S
     153.316331  30 Gallon
      153.326331  30 Gallon 240 V 
    						
    							
    24
    6 YEAR LIMITED WARRANTY ON WATER HEATER
    For six years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance 
    with the owner’s manual instructions and all local applicable plumbing codes, Sears will supply a free water heater for 
    one that develops a leak.
    For the second through sixth year from the purchase date, you must pay the labor cost for installation of water heater.
    For commercial, institutional, industrial or residential use by two or more families, the above limited warranty is only for 
    two years. During the second year you must pay the labor cost for water heater installation.
    1 YEAR EXCLUSIVE KENMORE LABOR WARRANTY
    For  the  first  year  from  the  date  of  purchase,  Sears  will,  free  of  charge,  supply  and  install  new  water  heater  parts  for 
    defective ones or a new water heater for one that develops a leak.
    WARRANTY SERVICE
    To obtain warranty service, call 1-800-4-MY-HOME® (1-800-469-4663). This warranty applies only while this product is 
    in use in the United States.
    This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
    SEARS, ROEBUCK AND CO., Dept. 817 WA, Hoffman Estates, IL 60179 
    The model number of your water heater is found on the model rating plate on the front of the water heater. 
    Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A
    The price of your water heater does not include a free checkup service call. On water heater installations arranged by Sears, 
    Sears warrants the installation.
    A charge will be made on service calls due to poor or incomplete installation. These include:
     a. Adjusting thermostat  c. Leaks in pipes or fittings  b. Condensation 
    MASTER PROTECTION AGREEMENTS
    C o n g r a t u l a t i o n s  o n   m a k i n g   a   s m a r t   p u r c h a s e .   Yo u r   n e w 
    Kenmore®  product  is  designed  and  manufactured  for  years 
    of  dependable  operation.  But  like  all  products,  it  may  require 
    preventive maintenance or repair from time to time. That’s when 
    having a Master Protection Agreement can save you money and 
    aggravation.
    Purchase a Master Protection Agreement now and protect yourself 
    from unexpected hassle and expense.
    The Master Protection Agreement also helps extend the life of your 
    new product. Here’s what’s included in the Agreement:
    • 
    Expert Service by our 12,000 professional repair specialist.
    • 
    Unlimited  service  and  no  charge  for  parts  and  labor  on  all 
    covered repairs.
    • 
    “No-lemon” guarantee - replacement of your covered product 
    if four or more product failures occur within twelve months.
    • 
    Product replacement if your covered product can’t be fixed.
    • 
    Annual Preventive Maintenance Check at your request - no 
    extra charge. • 
    Fast help by phone - phone support from a Sears technician 
    on  products  requiring  in-home  repair,  plus  convenient  repair 
    scheduling.
    • 
    Power  surge  protection  against  electrical  damage  due  to 
    power fluctuations.
    • 
    Rental reimbursement if repair of your covered product takes 
    longer than promised.
    Once you purchase the Agreement, a simple phone call is all that 
    it takes for you to schedule service. You can call anytime day or 
    night, or schedule a service appointment on-line.
    Sears has over 12,000 professional repair specialists, who have 
    access to over 4.5 million quality parts and accessories. That’s the 
    kind of professionalism you can count on to help prolong the life 
    of your new purchase for years to come. Purchase your Master 
    Protection Agreement today!
    Some  limitations  and  exclusions  apply.  For  prices  and 
    additional information call 1-800-827-6655.
    SEARS INSTALLATION SERVICE
    For  Sears  professional  Installation  of  home  appliances,  garage 
    door openers, water heaters, and other major home items, in the 
    U.S.A., call 1-800-4-MY-HOME®.
    For in-home major brand repair serviceCall 24 hours a day, 7 days a week (U.S.A. and Canada)
    1-800-4-MY-HOME®
    (1-800-469-4663)www.sears.com  
    						
    All Kenmore manuals Comments (0)