INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, May 1990 FIGURE 6-2. SYSTEM TROUBLESHOOTING CHART (CONT’D) SYMPTOM Unable to interface with computer call-up device (banking machine, answering machine, auto dialer, etc.) PROBABLE CAUSE Equipment being called is defective DTMF digit duration/ pause specifications of called equipment is incompatible with GMX-48 System CORRFCTIVE ACTION Ensure that the called equipment is functioning correctly. Check with...
Page 382
TROUBLESHOOTING Issue 2, May 1990 INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE FIGURE 6-2. SYSTEM TROUBLESHOOTING CHART (CONT’D) SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION RFI/EMI present over AC power source or conversations grounding incorrect Verify that the AC circuit is isolated and dedicated (see page 3-3) and check for proper grounding (see page 3-26). Grounding point is source of RFI/EMI While the system is running on AC power, temporarily remove the grounding wire to...
Page 384
TROUBLESHOOTING Issue 2, May 1990 INTER-TEL PRACTICES GMX.48 INSTALLATION & MAINTENANCE FIGURE 6-3. C.O. LINE TROUBLESHOOTING CHART (CONT’D) SYhlPTOhj Cannot obtain C.O. dial tone PROBABLF CAUSE If reorder tone is heard, programming error If progress tone is heard, user error System is programmed to expect a forced account code. Refer to PROGRAMMING, page 5-22 and 5-49. Defective system channel or switching matrix Perform network self test. Refer to PROGRAMMING, page 5-128. Defective...
Page 385
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, May 1990 FIGURE 6-3. C.O. LINE TROUBLESHOOTING CHART (CONT’D) SYMPTOM PROBABLE CAUSE CORRFCTIVE ACTION Cannot place an outgoing call. C.O. dial tone is present. Intercom works. Programming error :.:; .j Defective C.O. line from central office Defective station instrument Defective system channel or switching matrix Defective C.O. circuit Defective KCB Check station class of service (SCOS). See PROGRAMMING,...
Page 386
TROUBLESHOOTING Issue 2, May 1990 INTER-TEL PRACTICES GMX.48 INSTALLATION dz MAINTENANCE FIGURE 6-3. C.O. LINE TROUBLESHOOTING CHART (CONT’D) SYMPTOM Outside calls dropped during conversation or upon answering C.O. line PROBABLE CAUSE User error (line key being pressed after initial connection is made) Defective C.O. line from central office Insufficient loop current supplied by central office IC-CO disconnect timer value is set too sensitive Inter-ring silence timer value is set too...
Page 387
INTER-TEL PRACTICES TROUBLESHOOTING GMX-48 INSTALLATION & MAINTENANCE Issue 2, May 1990 FIGURE 6-3. C.O. LINE TROUBLESHOOTING CHART (CONT’D) SYMPTOM J’ROBABLF CAUSE CORRFCTIVE ACTION Noise on C.O. line at all stations Defective C.O. line At the C.O. block, remove the bridging clips for the line. On the telco side of the block, use a test set to verify the C.O. line connection. Also, move the C.O. line to a different C.O. circuit. If the problem follows the line, contact the telephone company....
Page 388
TROUBLESHOOTING INTER-TEL PRACTICES Issue 2, May 1990 GMX-48 INSTALLATION & MAINTENANCE FIGURE 6-3. C.O. LINE TROUBLESHOOTING CHART (CONT’D) SYMPTOM Other station conversations can be heard on the C.O. line (cross-talk) PROBABLE CAUSE Defective C.O. line(s) CORRECTIVE ACTION Isolate the line(s) with cross-talk by removing the bridging clips from the C.O. block. On the telco side of the block, attach a test set to each line and check for cross-talk. If present, contact the phone company....
Page 389
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, May 1990 FIGURE 6-4. FEATURE TROUBLESHOOTING CHART SYMPTOM Feature does not work properly J’ROBABLE CAUSE User error Programming error Defective station instrument Replace the station instrument and/or perform the keyset self-test as described in INSTALLATION, page 3-40. Defective station circuit Replace defective KCB, EXP, or APM. Defective KCB Refer to page 6-2 to test the system voltages. Replace the control...
Page 390
TROUBLESHOOTING Issue 2, May 1990 INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE FIGURE 6-4. FEATURE TROUBLESHOOTING CHART (CONT’D) SYMPTOM PROBABLE CAUSF CORRFCTIVE ACTION Cannot transfer incoming C.O. calls or place them on hold User error Inter-ring silence timer is set too sensitive User error (line key being pressed after initial connection is made) Programming error Refer to FEATURES for procedures. Ensure timer value is set longer than the C.O. ring off time. Refer to...