Page 371
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, May 1990 FIGURE 6-l. LIGHT-EMITTING DIODE (LED) INDICATIONS l!Js RUN DFSCRlPTlON Lit when the KSU is functioning normally. Flashes when the KSU is not operating properly. CO BUSY Lit when there is a C.O. call in progress. IC BUSY MINOR ALARM Lit when there is an intercom call in progress. Lit when a minor alarm has occurred. The light goes out when the alarm message is cleared (as described in FEATURES, page...
Page 372
TROUBLESHOOTING Issue 2, May 1990 INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE 4. ALARM MESSAGES AND FIELD (check wiring), defective station cable, or a de- SERVICE DIAGNOSTICS fective KCB or EXP 4.1 Alarm messages can be programmed to appear on display keysets, in the SMDR printout, or as a separate error printout. When listed in a printout, alarm messages are preceded by + + + and the time of day when the alarm occurred. (2) #ll Write Protect Circuit Fail: The circuitry that prevents...
Page 373
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, May 1990 (12) #22 Accessory Port B - No Txt Int.: The APM RS-232-C port has no transmit interrupt func- tion. Replace the APM and return it for repair. (13) #23 Accessory Port B - No Clock: There is a problem with the clock on the APM. Replace the APM and return it for repair. .‘: .$’ , :; ‘.: ., C. MAJOR ALARMS THAT REQUIRE IMMEDIATE ATTENTION 4.4 If a major alarm is detected by the system, the RUN LED...
Page 374
TROUBLESHOOTING Issue 2, May 1990 INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE b. C. d. e. f. ?? $xX: The system has detected an invalid data byte from a keyset or DSS/BLF Unit. This message may occur when the line cord is removed from a keyset or DSS/BLF Unit and when the 25pair cable is removed from the KCB or an EXI? In these cases, no action is required. However, if the error oc- curs repeatedly for a station circuit or a group of station circuits for which the line cord or...
Page 375
INTER-TEL PRACTICES TROUBLESHOOTING GMX-48 INSTALLATION 2% MAINTENANCE Issue 2, May 1990 (6) (7) (8) The following messages indicate minor soft- ware errors. Although they detect inconsistent operation, they generally do not warrant a sys- tem reset. If any of these messages should oc- cur, note the circumstances under which they occurred and contact Customer Support. Invalid Input > Keyset: Xx State: XXX Input: XX Invalid Input >Keyset: XX State: Xxx Timer No.: XX Invalid Input >SL Set: XX...
Page 376
TROUBLESHOOTING INTER-TEL PRACTICES Issue 2, May 1990 GMX-48 INSTALLATION & MAINTENANCE 5. TROUBLESHOOTING CHARTS 5.1 The troubleshooting charts located on the fol- lowing pages list symptoms, possible causes, and cor- rective actions for problems. Look up the problem in the appropriate chart and perform the corrective actions in the order given. The troubleshooting pro- cedures for correcting equipment failures have been divided into five categories: A. System B. C.O. Lines C. Features D....
Page 377
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE ‘.. TROUBLESHOOTING Issue 2, May 1990 E. SINGLE-LINE SETS 5.6 The following problems are discussed in Figure 6-6 on pages 6-34 through 6-37. 0 l _: 0 --. a 0 l Single-line set is inoperative. A group of six single-line sets is inoperative. Cannot obtain intercom dial tone. Cannot place an intercom call. Cannot break C.O. dial tone. Cannot place off-hook voice announce calls. 0 Single-line sets not receiving message waiting in-...
Page 378
TROUBLESHOOTING INTER-TEL PRACTICES Issue 2, May 1990 GMX-48 INSTALLATION & MAINTENANCE FIGURE 6-2. SYSTEM TROUBLESHOOTING CHART SYMPTOM Repeated occurrence of dropped calls J’ROBAf3L.F CAUSF AC line is not isolated and dedicated Defective power supply KSU located near a strong magnetic field or other potential source of interference (copy machines, power transformer, etc.) IC-CO/CO-CO discon- nect timer(s) need(s) adjustment Inter-ring silence timer value is set too sensitive...
Page 379
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, May 1990 FIGURE 6-2. SYSTEM TROUBLESHOOTING CHART (CONT’D) SYMPTOM Auto-answer modem for remote programming inoperative PROBABLE CAUSE Baud rate does not match RS-232-C port and/or the commu- nication parameters are not compatible Refer to page 2-16 for proper settings and complete specifications. Defective cable Replace the cable. Defective modem Refer to the manual included with the modem. Improper...
Page 380
TROUBLESHOOTING Issue 2, May 1990 I. INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE FIGURE 6-2. SYSTEM TROUBLESHOOTING CHART (CONT’D) SYMPTOM DISA inoperative PROBABLE CAUSE User error Telephone not User must dial in from a DTMF compatible telephone. Programming error Ensure that the DISA line is identified correctly as a day or night DISA line. Refer to PROGRAMMING, page 5-39. Perform network self test. Refer to PROGRAMMING, page 5-128. Defective system channel or switching...