INTER-TEL PRACTICES 
GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING 
Issue 2, May 1990 
FIGURE 6-l. LIGHT-EMITTING DIODE (LED) INDICATIONS 
l!Js 
RUN 
DFSCRlPTlON 
Lit when the KSU is functioning normally. Flashes when the KSU is not operating 
properly. 
CO BUSY Lit when there is a C.O. call in progress. 
IC BUSY 
MINOR ALARM Lit when there is an intercom call in progress. 
Lit when a minor alarm has occurred. The light goes out when the alarm message is 
cleared (as described in FEATURES, page...

Page 372

TROUBLESHOOTING Issue 2, May 1990 INTER-TEL PRACTICES 
GMX-48 INSTALLATION & MAINTENANCE 
4. ALARM MESSAGES AND FIELD (check wiring), defective station cable, or a de- 
SERVICE DIAGNOSTICS fective KCB or EXP 
4.1 Alarm messages can be programmed to appear 
on display keysets, in the SMDR printout, or as a 
separate error printout. When listed in a printout, 
alarm messages are preceded by + + + and the time 
of day when the alarm occurred. (2) #ll Write Protect Circuit Fail: The circuitry 
that prevents...

Page 373

INTER-TEL PRACTICES 
GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING 
Issue 2, May 1990 
(12) #22 Accessory Port B - No 
Txt Int.: The APM 
RS-232-C port has no transmit interrupt func- 
tion. Replace the APM and return it 
for repair. 
(13) #23 Accessory Port B - No Clock: There is a 
problem with the clock on the APM. Replace 
the APM and return it for repair. 
.‘: 
.$’ 
, 
:; 
‘.: 
., C. MAJOR ALARMS THAT REQUIRE 
IMMEDIATE ATTENTION 
4.4 If a major alarm is detected by the system, the 
RUN LED...

Page 374

TROUBLESHOOTING 
Issue 2, May 1990 INTER-TEL PRACTICES 
GMX-48 INSTALLATION & MAINTENANCE 
b. 
C. 
d. 
e. 
f. ?? $xX: The system has detected an invalid 
data byte from a keyset or DSS/BLF Unit. 
This message may occur when the line cord 
is removed from a keyset or DSS/BLF Unit 
and when the 25pair cable is removed 
from the KCB or an EXI? In these cases, no 
action is required. However, if the error oc- 
curs repeatedly for a station circuit or a 
group of station circuits for which the line 
cord or...

Page 375

INTER-TEL PRACTICES TROUBLESHOOTING 
GMX-48 INSTALLATION 2% MAINTENANCE 
Issue 2, May 1990 
(6) 
(7) 
(8) 
The following messages indicate minor soft- 
ware errors. Although they detect inconsistent 
operation, they generally do not warrant a sys- 
tem reset. If any of these messages should oc- 
cur, note the circumstances under which they 
occurred and contact Customer Support. 
Invalid Input > Keyset: Xx State: XXX Input: XX 
Invalid Input >Keyset: XX State: Xxx Timer No.: XX 
Invalid Input >SL Set: XX...

Page 376

TROUBLESHOOTING INTER-TEL PRACTICES 
Issue 2, May 1990 GMX-48 INSTALLATION & MAINTENANCE 
5. TROUBLESHOOTING CHARTS 
5.1 The troubleshooting charts located on the fol- 
lowing pages list symptoms, possible causes, and cor- 
rective actions for problems. Look up the problem in 
the appropriate chart and perform the corrective 
actions in the order given. The troubleshooting pro- 
cedures for correcting equipment failures have been 
divided into five categories: 
A. System 
B. C.O. Lines 
C. Features 
D....

Page 377

INTER-TEL PRACTICES 
GMX-48 INSTALLATION & MAINTENANCE 
‘.. 
TROUBLESHOOTING 
Issue 2, May 1990 
E. SINGLE-LINE SETS 
5.6 The following problems are discussed in Figure 
6-6 on pages 6-34 through 6-37. 
0 
l 
_: 0 
--. 
a 
0 
l 
Single-line set is inoperative. 
A group of six single-line sets is inoperative. 
Cannot obtain intercom dial tone. 
Cannot place an intercom call. 
Cannot break C.O. dial tone. 
Cannot place off-hook voice announce calls. 0 Single-line sets not receiving message waiting in-...

Page 378

TROUBLESHOOTING INTER-TEL PRACTICES 
Issue 2, May 1990 GMX-48 INSTALLATION & MAINTENANCE 
FIGURE 6-2. SYSTEM TROUBLESHOOTING CHART 
SYMPTOM 
Repeated occurrence 
of dropped calls 
J’ROBAf3L.F CAUSF 
AC line is not isolated 
and dedicated 
Defective power 
supply 
KSU located near a 
strong magnetic field 
or other potential 
source of interference 
(copy machines, power 
transformer, etc.) 
IC-CO/CO-CO discon- 
nect timer(s) need(s) 
adjustment 
Inter-ring silence timer 
value is set too sensitive...

Page 379

INTER-TEL PRACTICES 
GMX-48 INSTALLATION & MAINTENANCE TROUBLESHOOTING 
Issue 2, May 1990 
FIGURE 6-2. SYSTEM TROUBLESHOOTING CHART (CONT’D) 
SYMPTOM 
Auto-answer modem 
for remote programming 
inoperative 
PROBABLE CAUSE 
Baud rate does not 
match RS-232-C port 
and/or the commu- 
nication parameters 
are not compatible Refer to page 2-16 for proper settings and 
complete specifications. 
Defective cable Replace the cable. 
Defective modem Refer to the manual included with the 
modem. 
Improper...

Page 380

TROUBLESHOOTING 
Issue 2, May 1990 
I. 
INTER-TEL PRACTICES 
GMX-48 INSTALLATION & MAINTENANCE 
FIGURE 6-2. SYSTEM TROUBLESHOOTING CHART (CONT’D) 
SYMPTOM 
DISA inoperative 
PROBABLE CAUSE 
User error 
Telephone not User must dial in from a DTMF 
compatible telephone. 
Programming error Ensure that the DISA line is identified 
correctly as a day or night DISA line. 
Refer to PROGRAMMING, page 5-39. 
Perform network self test. Refer to 
PROGRAMMING, page 5-128.  Defective system 
channel or switching...