VI QUICK REFERENCE GUIDE [Using the keypad] ➥E nter the desired frequency via the keypad.•Direct input can be set until 1 kHz digit, rotate [R-DIAL]to set below 1 kHz frequency after set tuning steps, if necessary. (See p. 14 for setting the tuning step.) •Pushing [VFO MHz]omits the entry of 100 kHz and below, when you want to edit to these digits “0.” •Push [DUALWATCH]to cancel the entry.5. Receive mode selection➥Push [MODE SCAN]several times to select the desired re- ceive mode.•FM, WFM, AM, LSB, USB and CW are available. ■Memory programmingThe IC-R20 has a total of 1250 memory channels (including 200 auto write channels and 50 scan edges) for storing often used receive frequency, mode, etc.1. Setting frequencyIn VFO mode, set the desired receive frequency mode.•When “µ µ ” indicator is displayed, push [VFO MHz]to select the VFO mode.2. Selecting a memory channelPush [MR S.MW]for 1 sec., then rotate [R-DIAL]to select the de- sired memory channel. •“µ µ ” indicator blinks.3. Writing a memory channelPush [MR S.MW]for 1 sec. until 3 beeps sound.•Memory channel number automatically increases when continuing to push [MR S.MW]after programming. FM>CLEAR CLEAR -SKIP SKIP-:OFF :OFF -MNAME: MNAME: -BNAME: -BNAME: -BANK BANK-:---- :----999 999 µ . 146 .010 123 4560 789BANDDUALWATCH MAIN/SUB POWER VFO MHzMODE SCANMR S.MW SCOPE LOCK RECAFC MR S.MWFront To p 123 4560 789BANDDUALWATCH MAIN/SUB POWER VFO MHzMODE SCANMR S.MW SCOPE LOCK RECAFC MODE SCANFront 123 4560 789BANDDUALWATCH MAIN/SUB POWER VFO MHzMODE SCANMR S.MW SCOPE LOCK RECAFC VFO MHz 123 4560 789 LOCKAFC Front Quick reference guide

VII QUICK REFERENCE GUIDE■Programmed scan operation25 pairs, 50 channels of memories are used for programmed scan operation, that specify a scanning range. The pro- grammed scan scans between “xxA” and “xxB” (xx=00 to 24) frequencies. Therefore, before operating the programmed scan, different frequencies must be programmed into “A” and “B” channels.D D Programming scan edgesAstart frequency must be programmed into a “xxA,” and end frequency must be programmed into a “xxB” memory channel.1. Setting frequencyIn VFO mode, set the desired receive frequency mode.•When “µ µ ” indicator is displayed, push [VFO MHz]to select the VFO mode.2. Selecting a scan edge channel “A”Push [MR S.MW]for 1 sec., then rotate [R-DIAL]to select one of the desired scan edge channel “A.” •“µ µ ” indicator blinks. 3. Writing a memory channelPush [MR S.MW]for 1 sec. until 3 beeps sound.•Scan edge channel “B” is automat- ically selected when continuing to push [MR S.MW]after program- ming. •After programming is completed, return to VFO indication.4. Selecting a scan edge channel “B”Push [MR S.MW]for 1 sec., then ro- tate [R-DIAL]to select one of the desired scan edge channel “B.” •“µ µ ” indicator blinks. •When the scan edge channel “B” is al- ready selected at step 3. (continuing to push [MR S.MW]after programming), skip this step.5. Writing a memory channelPush [MR S.MW]for 1 sec. until 3 beeps sound.•The next scan edge channel “A” is automatically selected when con- tinuing to push [MR S.MW]after programming. •After programming is completed, return to VFO indication. FM-BNAME: -BNAME: -BANK BANK-:---- :----03B 03B µ . 146 .010 123 4560 789BANDDUALWATCH MAIN/SUB POWER VFO MHzMODE SCANMR S.MW SCOPE LOCK RECAFC MR S.MWFront To p 123 4560 789BANDDUALWATCH MAIN/SUB POWER VFO MHzMODE SCANMR S.MW SCOPE LOCK RECAFC MR S.MWFront FM-BNAME: -BNAME: -BANK BANK-:---- :----03A 03A µ . 146 .010 123 4560 789BANDDUALWATCH MAIN/SUB POWER VFO MHzMODE SCANMR S.MW SCOPE LOCK RECAFC MR S.MWFront To p

VIII QUICK REFERENCE GUIDE D D Starting scan 1. Select VFO mode.Push [VFO MHz]to select the VFO mode for full, band and programmed scan operation.•Select memory mode by pushing [MR S.MW]for memory or bank scan.2. Selecting a scanning typeWhile pushing and holding [MODE SCAN], rotate [R-DIAL] to select one of the desired scanning type. •Available scan types when VFO mode is selected; “ALL” for full scan; “BAND” for the selected band; one of “PROGxx” (xx=0 to 24) for programmed scan. •Available scan types when memory bank is selected; “ALL” for all mem- ory scan, “BANK-LINK” for bank- link scan; “BANK” for the selected bank scan. 3. Starting scanRelease [MODE SCAN]to start the scan.•Rotate [R-DIAL]to change the scanning direction.4. Cancelling scanPush [DUALWATCH]to stop the scan.✔For your information The memory channel number you program the scan edges into correlate “PROGxx” as follows: 00A/00B: Scans between frequencies programmed in 00A and 00B channels, and select “PROG-00” 01A/01B: Scans between frequencies programmed in 01A and 01B channels, and select “PROG-01” • • • 24A/24B: Scans between frequencies programmed in 24A and 24B channels, and select “PROG-24” SCAN:ALL√ PSKIP SCAN:BAND√ PSKIP SCAN:PROG-01√ PSKIP √MODE MODE ANLAFC TSQL FM FM 148888148888 00000000 PS PSKI KIP -DUP √MODE MODE ANLAFC TSQL FM FM PS PSKI KIP -DUP P01 • During full/band scan • During programmed scan√ µ MODE MODE ANLAFC TSQL FM FM 888888888888 000000 PSKIP -DUP 012 √ µ MODE MODE ANLAFC TSQL FM FM 000000 PSKIP -DUP P01 • During memory/all/bank scan • During bank scan 123 4560 789BANDDUALWATCH MAIN/SUB POWER VFO MHzMODE SCANMR S.MW SCOPE LOCK RECAFC MODE SCAN SCAN:ALL√ PSKIP SCAN:BAND√ PSKIP SCAN:PROG-01√ PSKIP • Full scan • Band scan • Programmed scan Selectable between “00” to “24” if programmed Front To p Quick reference guide

■Front, top and side panels qANTENNA CONNECTOR (p. II) BNC connector: Connects the supplied antenna. wSQUELCH KEY [SQL] (p. 18) ➥Push and hold to temporarily open the squelch and monitor the operating frequency. ➥While pushing this key, rotate the tuning dial* to adjust the squelch level. eUP/DOWN KEYS [Y Y ]/[Z Z ] Adjust audio volume level.* (p. 17) rUSB JACK [USB] Connects to a PC using an optional OPC-1382 CLONING CABLE for cloning. Cloning allows you to quickly and easily transfer the programmed contents between the IC-R20 and the connected PC. tEXTERNAL DC-IN CONNECTOR [DC] (p. 9) Connects an AC adaptor or an optional cigarette lighter cable for both charging the installed re-chargeable battery pack and operating. yEXTERNAL SPEAKER CONNECTOR [SP/CI-V] ➥Connect an optional earphone or headphone. The internal speaker will not function when any exter- nal equipment is connected. (See p. 80 for a list of available options.) ➥Connect an optional CT-17 for remote control operation. (p. 68) q w er ty u i KEYPAD 1 PANEL DESCRIPTION 1

2 1 PANEL DESCRIPTION 1 uLEFT DIAL [L-DIAL] ➥During single band operation, rotate to adjust audio vol- ume level.* (p. 17) ➥During dualwatch operation, activates as the tuning dial for upper side on the display.* iRIGHT DIAL [R-DIAL] ➥Rotate to select the operating frequency.* (p. 12) ➥While scanning, changes the scanning direction.* (p. 26) ➥While pushing [SQL], sets the squelch level.* (p. 18) ➥While pushing [VFO MHz], sets the operating frequency in 1 MHz or 10 MHz in VFO mode.* (p. 14) ➥While pushing [BAND], selects the operating band in VFO mode.* (p. 14) ➥While dualwatch operation, activates as the tuning dial for lower side on the display.* (p. 14)KEYPAD qDUALWATCH/CLEAR KEY [DUALWATCH] ➥Push for 1 sec. to toggle between single band and dualwatch operation. (p. 24) ➥Clears numeric key input. (p. 15) ➥Returns to previous operating condition while setting frequency or memory channel, or while in set mode. ➥Cancels the band scope or scan function, etc. (pgs. 22, 35) wMAIN/SUB KEY [MAIN/SUB] (p. 24) ➥During dualwatch operation, push to select the MAIN band or SUB band. ➥During dualwatch operation, push for 1 sec. to exchange the upper frequency and lower fre- quency. ePOWER KEY [POWER] Push for 1 sec. to turn the receiver power ON and OFF. rBAND KEY [BAND] Push to select the operating frequency band. (p. 12) BANDPOWERMAIN/SUBDUALWATCH DIAL.SEL SWEEP CENTER T-SCAN SKIP M.N TONE SET TS AT TRF GAIN IC Recorder 123 4560 789BANDDUALWATCH MAIN/SUB POWER VFO MHzMODE SCANMR S.MW SCOPE LOCK RECAFC *The function of tuning control and volume control can be traded. See page 23 for details.

3 1 PANEL DESCRIPTION tVFO/MHz KEY [VFO MHz] ➥Push to select VFO mode. (p. 11) ➥Push for 1 sec. to toggle between the 1 MHz or 10 MHz tuning steps (p. 14) yMODE/SCAN KEY [MODE SCAN] ➥Push to select the operating mode (FM, WFM, AM, USB, LSB, CW). (p. 16) ➥Push for 1 sec. to start a scan. (p. 35) uMEMORY KEY [MR S.MW] ➥Push to select between memory mode, TV channel and PreSet channel. (p. 11) ➥Push for 1 sec. to enter memory write condi- tion. (p. 26) ➥Push for 2 sec. to write the operating fre- quency into the selected memory channel in VFO mode. Push [MR S.MW]for 2 sec. to transfer the dis- played frequency into the VFO in memory mode. (p. 31)iVOLUME/DIAL KEY [1 DIAL.SEL] ➥Inputs digit ‘1’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to trade the volume control ([L-DIAL], [Y Y ]/[Z Z ]) and tuning control ([R- DIAL]) functions. (p. 23) •“√ √ ” appears when the normal operation. •“∂ ∂ ” appears when the functions of the tuning control and volume control are traded. oSWEEP KEY [2 SWEEP](p. 22) ➥Inputs digit ‘2’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to select the tuning step for band scope function. Once this key is pushed, the band scope function sweeps once via the new tuning step. !0CENTER KEY [3 CENTER](p. 22) ➥Inputs digit ‘3’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to return the display frequency of the band frequency. !1SCOPE KEY [SCOPE](p. 22) ➥Push to activate the band scope function dur- ing normal operating condition. Or push to stop continuous sweeping. ➥Push for 1 sec. to start continuous sweeping. SCOPECENTERSWEEPDIAL.SEL MR S.MWMODE SCANVFO MHz

4 1 PANEL DESCRIPTION 1 !2TONE SCAN KEY [4 T-SCAN] ➥Inputs digit ‘4’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to start a tone scan. (p. 48) !3FREQUENCY SKIP KEY [5 SKIP] ➥Inputs digit ‘5’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to turn the frequency skip function ON and OFF in VFO mode. (p. 39) •“PSKIP” appears when the frequency skip function is in use.➥Push for 1 sec. to set the memory channel as the following skip channel in memory mode in order. (p. 39)•Skip channel — “SKIP” appears. •Frequency skip channel — “PSKIP” appears. •Non-skip channel — no skip indicator appears.➥Push for 1 sec. to program a paused fre- quency as a skip frequency while scanning. (p. 39) !4MEMORY NAME KEY [6 M.N] ➥Inputs digit ‘6’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to turn the memory name indi- cation ON and OFF. (p. 30)!5AFC KEY [0 AFC] ➥Inputs digit ‘0’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to turn the AFC (Automatic Frequency Control) function ON and OFF. (p. 21) !6TONE SQUELCH KEY [7 TONE] ➥Inputs digit ‘7’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to activate the following tone squelch functions in order. •Tone squelch — “TSQL” appears. (p. 45) •Pocket beep — “TSQLS” appears. (p. 45) •DTCS squelch — “DTCS” appears. (p. 45) •DTCS beep — “DTCSS” appears. (p. 45) •VSC function — “VSC” appears. (p. 45) •No tone operation — no tone indicator appears. !7SET MODE KEY [8 SET] ➥Inputs digit ‘8’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to enter the set mode. SETTONEAFC M.N6SKIPT SCAN

5 1 PANEL DESCRIPTION !8TUNING STEP KEY [9 TS] ➥Inputs digit ‘9’ for frequency input, memory channel selection, etc. ➥Push for 1 sec. to select the tuning step. (p. 14) !9LOCK KEY [• LOCK] ➥Inputs MHz digit for frequency input. (p. 15) ➥Push for 1 sec. to toggle the lock function ON and OFF. (p. 16) •“” appears while the key lock function is in use. @0REWIND/ATTENUATOR KEY [ Ω ΩΩ Ω ATT] ➥Push to select the track for recorded audio. (p. 64) ➥Push and hold to rewind during playing the recorded audio. (p. 64) ➥Push for 1 sec. to turn the attenuator function ON and OFF during normal operation. (p. 19) @1FAST FORWARD/RF GAIN KEY [≈ ≈≈ ≈ RF GAIN] ➥Push to select the track for recorded audio. (p. 64) ➥Push and hold to fast forward through the recorded contents. (p. 64) ➥Push for 1 sec. to enter the RF GAIN set mode. Push to select the level after selecting with [R-DIAL]. (p. 19)@2STOP/PLAY [■ ≈ ≈] ➥Push to start the recorded audio. (p. 64) ➥Push to stop the recording or playing audio. (p. 64) ➥Push for 1 sec. to enter the play speed set mode. Push to select the item after selecting with [R-DIAL]. (p. 65) @3RECORD KEY [ REC] ➥Push to start recording audio. (p. 64) ➥Push to pause recording audio. (p. 64) ➥Push for 1 sec. to enter the record set mode. Push to select the item after selecting with [R- DIAL]. (p. 65) REC RF GAINAT TLOCKTS

6 1 PANEL DESCRIPTION 1 ■Function displayqBATTERY INDICATOR ➥“” appears when the installed batteries have ample capacity. •They do not appear when operating with an external power source. ➥“” appears when the batteries are nearing ex- haustion. •IC-R20 installed the BP-206 must be charged presently, but when it installed alkaline batteries can be operate for a while. ➥Scrolls while charging the installed BP-206. (p. 8) ➥Battery indicator blinks when completely charged.wDUPLEX INDICATORS (p. 20) “+DUP” appears when plus semi-duplex, “–DUP” appears when minus semi-duplex (repeater) operation is selected. eSIGNAL SQUELCH INDICATORS ➥“TSQL” appears while the tone squelch function is in use. (p. 45) ➥“DTCS” appears while the DTCS squelch function is in use. (p. 45) ➥“S” appears with the “TSQL” or “DTCS” indicator while the pocket beep function (with CTCSS or DTCS) is in use. (p. 45) ➥“VSC” appears while the VSC (Voice Squelch Control) function is in use. (p. 45) 145000 433000 -DUP -DUP FM TSQL TSQL PS PS PRIO PRIO FM000 000 ATT M:Amateur2√ µ MODE AFCAFC PRIRI O TSQL TSQLFM 145000 PSKIP -DUP 000000 q q w w w e e e t r t y !6 uu u i i i oo o !0!0 !0 !1 !1 !2 !2 !5 !4 !3!6 !5 !4 !4 !5 ANL

7 1 PANEL DESCRIPTION rANL/NB INDICATOR(pgs. 21, 52) ➥“ANL” appears when the ANL (Automatic Noise Limitter) function is in use. The ANL function is available only for AM mode. ➥“NB” appears when the noise blanker function is in use. The noise blanker function is available while in LSB/USB/CW modes. tLOCK INDICATOR(p. 16) Appears when the lock function is activated. yAFC INDICATOR(p. 21) Appears when the AFC function is activated. •The AFC function is available for single band operation only. uSKIP INDICATORS(p. 39) ➥“SKIP” appears when the selected memory channel is specified as a skip channel. ➥“PSKIP” appears when the displayed frequency is spec- ified as a skip frequency. iCHANNEL SELECTION INDICATOR(p. 11) ➥“µ µ ” and three digits channel number appear when memory channel is selected. ➥“å å ” and three digits channel number appear when auto-memory write channel is selected. ➥“ TV ” appears when TV channel is selected. ➥( 0–9) channel number appears when PreSet channel is selected. ➥“ WX ”* appears when weather channel is selected. *Available for the USA version only. “å å ,” “ 0–9” and “ TV ” indications appear for single band operation only.oSIGNAL STRENGTH INDICATOR Shows the receiving signals relative to signal strength. !0PRIORITY WATCH INDICATOR(p. 42) Appears when priority watch is in use. !1ATTENUATOR INDICATOR (p. 19) Appears when the RF attenuator is in use. !2VOLUME/DIAL EXCHANGE INDICATOR (p. 23) ➥“√ √ ” appears when the normal operation. ➥“∂ ∂ ” appears when the functions of the tuning con- trol and volume control are traded. !3MEMORY/BANK NAME INDICATOR Shows the memory name or bank name. •This indication is available when memory name or bank name is programmed. !4FREQUENCY READOUT Shows an operating frequency. •The smaller readout appears at right when tuning step is se- lected 0.1 kHz or 0.01 kHz steps. •The decimal point blinks during scan. !5RECEIVE MODE INDICATOR (p. 16) Shows the selected receive mode. •FM, WFM AM, LSB, USB and CW are available. !6MAIN BAND INDICATOR (p. 24) Shows the main band on upper display or lower display. •This indication appears only when dualwatch operation.