    							OPERATING GUIDE
    iR3BASIC OPERATIONqPush [POWER] for 2 sec.
    wPush [↕] to set the desired audio
    level.
    eSelect VFO mode with [V/M].
    rSelect the desired band with [↔].
    tRotate [DIAL] to change the fre-
    quency.
    •The frequency changes according to
    the preset tuning steps.
    ySet the squelch level.
    •While pushing [SQL], rotate [DIAL].
    •The first click of [DIAL] indicates the
    current squelch level.
    •“LEVEL1”is loose squelch and
    “LEVEL9”is tight squelch.•“AUTO”indicates automatic level ad-
    justment.
    tWhen a signal is received:
    •Squelch opens and audio is emitted
    from the speaker.
    •The S/RF indicator shows the relative
    signal strength.
    ◊Using the dial select step(p. 39)
    Rotate [DIAL] while pushing [FUNC]
    to change the frequency in 100 kHz,
    1 MHz or 10 MHz steps.DUPLEX OPERATIONqSet the receive station frequency
    (e.g. repeater output frequency).
    wSet the shift direction of the trans-
    mit station frequency in set mode.
    (–DUP or DUP)
    ePush and hold [SQL] to monitor
    the transmit station’s frequency.◊Tone scan(p. 30)
    Push [FUNC] + [↔] for 2 sec. to start
    the tone scan.
    
    MEMORY CHANNEL SELECTION
    qPush [V/M] to select memory
    mode.
    •“M:”or “X”appears.
    wSelect a memory channel with
    [DIAL].
    eRotate [DIAL] while pushing
    [FUNC] to select the memory
    bank.MEMORY CLEARqSelect the desired memory chan-
    nel.
    wSelect VFO mode with [V/M] and
    push [V/M] for 1 sec. to indicate
    the channel.
    ePush [FUNC] + [V/M] for 2 sec.
    Important operating instructions are summed up in this and the following page
    for your simple reference.
    By cutting along the line and folding on the dotted line, it will become a card
    sized operating guide which can easily be carried in a card case or wallet,
    etc.
    q Cutw Folde Complete
    
    57
    19QUICK REFERENCE 
    						
    							58
    19QUICK REFERENCE
    SCAN◊Full/band/programmed scan
    qSelect VFO mode with [V/M].
    wMake sure the squelch is set to
    the threshold point.
    ePush [↔] for 2 sec. to start the
    scan.
    •Rotate [DIAL] while pushing [↔] to
    select scan edge, if desired.
    •To change the scanning direction, ro-
    tate [DIAL].
    rPush [↔] again to stop the scan.
    ◊Memory (bank) scan
    qSelect memory mode with [V/M].
    wMake sure the squelch is set to
    the threshold point.
    ePush [↔] for 2 sec. to start the
    scan.
    •Rotate [DIAL] while pushing [↔] to
    turn memory bank scan ON or OFF,
    if desired.
    rPush [↔] again to stop the scan.SET MODEqPush [FUNC] + [(MODE) SET]
    momentarily to enter set mode.
    •Select non-band scope screen in ad-
    vance for color LCD.
    wRotate [DIAL] to select a display.
    ePush [↔] or rotate [DIAL] while
    pushing [FUNC] to set the condi-
    tion.
    rPush [
    (MODE)
    SET] to exit set
    mode.
    LOCK FUNCTIONPush [FUNC] + [(MODE) SET] for 2
    sec. to toggle the lock function ON or
    OFF. (p. 9)
    CPU RESETTING◊Partial resetting(p. 45)
    While pushing [FUNC] and [V/M],
    turn power on to partially reset the
    receiver.•Partial resetting does not clear the mem-
    ory channel contents.◊Total resetting(p. 45)
    While pushing [FUNC], [V/M] and
    [MODE], turn power on to reset the
    receiver.
    Caution:
    Resetting the receiver
    initializes all memory contents. 
    						
    							DECLARATION
    OF CONFORMITY
    We Icom Inc. Japan6-9-16, Kamihigashi, Hirano-ku
    Osaka 547-0002, Japan
    Type-designation:       
    iC-r3
    Version (where applicable): Kind of equipment:     
    COMMUNICATIONS RECEIVER
    This compliances is based on conformity with the following harmonised
     standards, specifications or documents:
    i)   
    EN 60950ii)  prEN 301 489-1
    iii) prEN 301 489-15
    iv) prEN 301 783-2
    v)
    Signature Authorized representative name Place and date of issue
    T. Aoki
    General Manager Icom (Europe) GmbH
    Himmelgeister straße 100
    D-40225 Düsseldorf
    Düsseldorf 11. July. 2000
    Icom (Europe) GmbH
    Declare on our sole responsability that this equipment complies the
    essential requirements of the Radio and Telecommunications Terminal 
    Equipment Directive, 1999/5/CE. 
    						
    							Count on us!
    6-9-16 Kamihigashi, Hirano-ku, Osaka 547-0002 Japan
    A-5653H-1EX-w
    Printed in Japan
    © 2000 Icom Inc. 
    						
    All Icom manuals Comments (0)

    Related Manuals for Icom Ic-r3 Communications Reciever Instruction Manual