Page 41
5. Reseat the cable or connector of the detected FRU and run the test again. If the error recurs, replace the FRU that caused the error. Note:With some FRUs, especially the system board, the problem may be caused by peripheral FRUs. Verify that each peripheral FRU, such as the flexible cable, has no problem by doing the following: a. Replace each peripheral FRU one at a time, and run the test again. b. If the peripheral FRUs have no problem, replace the main FRU itself. To see the FRU structure of each...
Page 42
vPhysical Disk Drive vLogical Disk Drive vVGA Information vIDE Drive Information vPCI Information vPNPISA Information vSMBIOS Information vFRU Information vVESA LCD Information Utility: vRun External Tests vSurface Scan Hard Disk vBenchmark System vDOS Shell vTech Support Form vBattery Rundown vView Test Log vPrint Log vSave Log vFull Erase Hard Drive vQuick Erase Hard Drive Power systems checkout To verify the symptom of the power problem on the computer, do the following: 1. Power off the computer. 2....
Page 43
Checking the AC AdapterYou care here because the computer fails only when the AC Adapter is used: vIf the power-on indicator does not turn on, check the power cord of the AC Adapter for correct continuity and installation. vIf the operational charge does not work, go to“Checking operational charging”. Unplug the AC Adapter cable from the computer and measure the output voltage at the plug of the AC Adapter cable. See the following figure: Pin Voltage (V dc) 1 15.5 V. - 17.0 V. 2 Ground If the voltage is...
Page 44
Checking the Battery ASM Note:The Battery ASM may not be able to charged when it is hot. In that case, remove it from the computer and leave it at room temperature for a while. After it cools down, reinstall it and recharge it. Do the following: 1. Power off the computer. 2. Remove the battery pack and measure the voltage between battery terminals 1 (+) and 6 (-). See the following figure. 1 23456 Terminal Pin No. Description 1 1 +0 to +16.8 V 2 2 Isolation slit 5 4 Thermistor 6 5 Battery– Note:Signal...
Page 45
Symptom-to-FRU Index The Symptom-to-FRU Index lists the symptoms and errors and the possible causes. The most likely cause is listed first. Note:Perform the FRU replacement or actions in the sequence shown in the FRU/Action columns. If a FRU does not solve the problem, put the original part back in the computer. Do not replace a non-defective FRU. This index can also be used to help you decide which FRUs should be available when servicing a computer. Numeric error codes show the errors detected in POST...
Page 46
Error CodeMessage Meanings Comment or Action 0192 System Security-IBM Embedded Security hardware tamper detected.Security chip ID matching failed.System Board 0197 Invalid Remote Change RequestedReported when the CRC of request packet in EEPROM Block #7 is wrong.Recovery- Users need to send the system back to the service centers. 0199 System Security-IBM Security password retry count exceededSystem administrator password retry expired (if failed 3 times)1. Run IBM BIOS Setup Utility, and then save...
Page 47
Error CodeMessage Meanings Comment or Action 0220 Monitor type does not match CMOS Run SETUPMonitor type not correctly identified is Setup.Load Setup Defaults in IBM BIOS Setup Utility. 0230 Shadow RAM failed at offset : nnnnShadow RAM failed at offset nnnn of the 64k block at which the error was detected.System Board 0231 System RAM failed at offset : nnnnSystem RAM failed at offset nnnn of in the 64k block at which the error was detected.1. DIMM 2. System Board 0232 Extended RAM Failed at offset :...
Page 48
Error CodeMessage Meanings Comment or Action 0270 Real time clock errorReal-Time Clock fails BIOS hardware test. May require board repair.1. Replace the backup battery and run IBM BIOS Setup Utility to reset the time and date. 2. System Board 0271 Check date and time settingsBIOS found date or time out of range and reset the Real-Time Clock. May require setting legal date (1991–2099).Run IBM BIOS Setup Utility to reset the time and date. 0280 Previous boot incomplete-Default configuration usedPrevious...
Page 49
Error CodeMessage Meanings Comment or Action 02B2 Incorrect Drive A type—run SETUPType of floppy drive A: not correctly identified in SetupDiskette Drive 02B3 Incorrect Drive B type—run SETUPType of floppy drive B: not correctly identified in SetupDiskette Drive 02D0 System cache error- Cache disabledRAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers. You may have to replace that cache. See your dealer. A disabled cache slows system performance considerably.System...
Page 50
Error CodeMessage Meanings Comment or Action Allocation Error for: deviceRun ISA or EISA configuration Utility to resolve resource conflict for the specified device.1. Load Setup Defaults in IBM BIOS Setup Utility. 2. Backup battery 3. System Board CD ROM Drive CD ROM Drive identified. Entering SETUP Starting Setup program Failing Bits: nnnn The hex number nnnn is a map of the bits at the RAM address which failed the memory test. Each 1 (one) in the map indicates a failed bit. See errors 230, 231, or 232...