Table5-7Cleaning
CleaningProcedureTimeFrameComponent
Dustwithdamp,lint-freecloth.RegularlyKeyboard
UsetheHPVideoScreenCleaningSolutionfoundin92193MMaster
CleanKit.
RegularlyMonitorscreen
Seethemouse'smanualformousemaintenanceprocedures.RegularlyMouse
Checkfunctionsofcoolingfansandcleantheintakeopeningson
thechassisofdust,lint,andotherobstructionstoairflow.
SixMonthsCoolingfansandgrills
CAUTION:DONOTusepetroleum-basedcleaners(suchaslighterfluid)orcleanerscontaining...

Page 122

122 

Page 123

6RemovingandReplacingComponents
ThischapterdescribeshowtoremoveandreplacehardwareinHP9000rp3410andrp3440
servers.
CAUTION:Usecaretopreventinjuryandequipmentdamagewhenperformingthese
procedures.Voltagescanbepresentwithintheserver.Manyassembliesaresensitivetodamage
byelectrostaticdischarge.
SafetyInformation
Toensuresafehandlingofcomponents,preventpersonalinjury,andpreventdamagetothe
server,followtheprocedureslistedbelow:
•Ifremovingorinstallingahot-swaporhot-plugitem,followtheinstructionsprovidedin...

Page 124

Figure6-1InternalPhysicalLayout
Table6-1providesthekeytoFigure6-1.
Table6-1ComponentLocations
Hot-pluggableharddiskdrives(upto3)8Powerreceptacles(PWR1left,PWR2right)1
Harddiskdrive9Memoryairflowguide2
Systemfans(Fan2center,Fan3PCIcardcage)10Processorairflowguide3
Intrusionswitch11Systemfans(Fan1Aright,Fan1Bleft)4
Memorysockets12Slimlineopticaldrive5
PCIcardcage13Powersupplies:1center,powersupply2under
opticaldrive)
6
iLOMPcard14Statuspanelboard7
Figure6-2showsthesystemboardconnectorsandslots....

Page 125

Figure6-2SystemBoardConnectorsandSlots
Table6-2providesthekeytoFigure6-2.
Table6-2ConnectorLocations
PCIbackplaneconnector17Powersupplyfanconnector9ExternalSCSIconnector1
Opticaldriveconnector18Powermodulepowerconnector10SCSIconnectorsA&B2
iLOMPcardconnector19HPZX1memoryandI/Ocontroller
(underheatsink)
11CPUpowerpods3
HPZX1I/Oadapter20Memorysockets12CPU14
Serialports(2)(factoryuse
only)
21Statuspanelconnector13CPU05
USBconnectors(4)22Powermoduleauxiliaryconnector14Turbofanpowerconnectors6...

Page 126

RemovingandReplacingServerCoversandBezel
Toupgrade,remove,orreplacemostservercomponents,youmustfirstremovetheservercovers
fromthechassis.Thissectionexplainshowtoremoveandreplacetheservercoversandbezel
forrack-mountandpedestal-mountconfigurations.
WARNING!Donotremovetheservercoverwithoutfirstturningtheserveroffandunplugging
thepowercordfromtheoutletorpowerprotectiondeviceunlessyouareonlyreplacinga
hot-swappablefan.Alwaysreplacethecoverbeforeturningtheserveron.
AccessingaRack-MountServer...

Page 127

Figure6-3ReleasetheRackLatches
3.Slidetheserveroutoftherackuntiltheguide-railreleaseclipsarevisible.
InsertingtheServerIntotheRack
Toinserttheserverintotherack,followthesesteps:
1.Presstherailclipsoneithersideoftheserverinwardandpushtheserverintotherackuntil
itstops.
2.Verifythattheracklatchesareclosed.
RemovingandReplacingtheTopCoveronaRack-MountedServer
RemovingtheTopCoveronaRack-MountedServer
NOTE:Ifyouarereplacingahot-swappableitem,youcanleavetheserveronandexternal...

Page 128

Figure6-4RemovingtheTopCoveronaRack-MountedServer
3.Liftthetopcoverofftheserverchassis.
ReplacingtheTopCoveronaRack-MountedServer
CAUTION:Secureanywiresorcablesinyourserversotheywillnotgetcutorinterferewith
thereplacementofthetopcover.
Toreplacethetopcover,followthesesteps:
1.Alignthefrontedgeofthetopcoverwiththealignmentmarkontheopticaldrivebay.
Figure6-5AligningtheTopCoveronaRack-MountedServer
2.Graspthebluereleaseleverandslidethecovertowardthefrontoftheserveruntilthelever
snapsintoplace....

Page 129

Figure6-6ClosingtheTopCoveronaRack-MountedServer
3.Slidetheserverintotherackenclosureandreconnectthepowerandexternalcables.
RemovingandReplacingtheFrontBezelonaRack-MountedServer
Youmustremovethefrontbezelfromthechassistogainaccesstothepowersuppliesandoptical
drive.
RemovingtheFrontBezel
Toremovethefrontbezel,followthesesteps:
1.Pressinontheretainingclipslocatedontheright-sideofthefrontpanel.
Figure6-7FrontBezelRetainingClip
2.Rotatethefrontpaneloutwardandliftitofftheserverchassis....

Page 130

2.Closethebezelandpushtowardthefrontoftheserveruntilitlocksintoplace.
Figure6-8ReplacingtheFrontBezelonaRack-MountedServer
AccessingaPedestal-MountServer
BoththeHP9000rp3410andtherp3440serversareavailableinapedestalconfigurationorcan
beconvertedfromaracktoapedestalconfiguration.Toaccesstheinternalcomponentsona
pedestalserver,youmustremovethesideandtopcovers.
RemovingtheSideCoversonaPedestal-MountedServer
NOTE:Ifyouarereplacingahot-swappableitem,youcanleavetheserveronandexternal...