HP 9000 Dclass Manual
Here you can view all the pages of manual HP 9000 Dclass Manual. The HP manuals for Server are available online for free. You can easily download all the documents as PDF.
Page 121
Table5-7Cleaning CleaningProcedureTimeFrameComponent Dustwithdamp,lint-freecloth.RegularlyKeyboard UsetheHPVideoScreenCleaningSolutionfoundin92193MMaster CleanKit. RegularlyMonitorscreen Seethemouse'smanualformousemaintenanceprocedures.RegularlyMouse Checkfunctionsofcoolingfansandcleantheintakeopeningson thechassisofdust,lint,andotherobstructionstoairflow. SixMonthsCoolingfansandgrills CAUTION:DONOTusepetroleum-basedcleaners(suchaslighterfluid)orcleanerscontaining...
Page 123
6RemovingandReplacingComponents ThischapterdescribeshowtoremoveandreplacehardwareinHP9000rp3410andrp3440 servers. CAUTION:Usecaretopreventinjuryandequipmentdamagewhenperformingthese procedures.Voltagescanbepresentwithintheserver.Manyassembliesaresensitivetodamage byelectrostaticdischarge. SafetyInformation Toensuresafehandlingofcomponents,preventpersonalinjury,andpreventdamagetothe server,followtheprocedureslistedbelow: •Ifremovingorinstallingahot-swaporhot-plugitem,followtheinstructionsprovidedin...
Page 124
Figure6-1InternalPhysicalLayout Table6-1providesthekeytoFigure6-1. Table6-1ComponentLocations Hot-pluggableharddiskdrives(upto3)8Powerreceptacles(PWR1left,PWR2right)1 Harddiskdrive9Memoryairflowguide2 Systemfans(Fan2center,Fan3PCIcardcage)10Processorairflowguide3 Intrusionswitch11Systemfans(Fan1Aright,Fan1Bleft)4 Memorysockets12Slimlineopticaldrive5 PCIcardcage13Powersupplies:1center,powersupply2under opticaldrive) 6 iLOMPcard14Statuspanelboard7 Figure6-2showsthesystemboardconnectorsandslots....
Page 125
Figure6-2SystemBoardConnectorsandSlots Table6-2providesthekeytoFigure6-2. Table6-2ConnectorLocations PCIbackplaneconnector17Powersupplyfanconnector9ExternalSCSIconnector1 Opticaldriveconnector18Powermodulepowerconnector10SCSIconnectorsA&B2 iLOMPcardconnector19HPZX1memoryandI/Ocontroller (underheatsink) 11CPUpowerpods3 HPZX1I/Oadapter20Memorysockets12CPU14 Serialports(2)(factoryuse only) 21Statuspanelconnector13CPU05 USBconnectors(4)22Powermoduleauxiliaryconnector14Turbofanpowerconnectors6...
Page 126
RemovingandReplacingServerCoversandBezel Toupgrade,remove,orreplacemostservercomponents,youmustfirstremovetheservercovers fromthechassis.Thissectionexplainshowtoremoveandreplacetheservercoversandbezel forrack-mountandpedestal-mountconfigurations. WARNING!Donotremovetheservercoverwithoutfirstturningtheserveroffandunplugging thepowercordfromtheoutletorpowerprotectiondeviceunlessyouareonlyreplacinga hot-swappablefan.Alwaysreplacethecoverbeforeturningtheserveron. AccessingaRack-MountServer...
Page 127
Figure6-3ReleasetheRackLatches 3.Slidetheserveroutoftherackuntiltheguide-railreleaseclipsarevisible. InsertingtheServerIntotheRack Toinserttheserverintotherack,followthesesteps: 1.Presstherailclipsoneithersideoftheserverinwardandpushtheserverintotherackuntil itstops. 2.Verifythattheracklatchesareclosed. RemovingandReplacingtheTopCoveronaRack-MountedServer RemovingtheTopCoveronaRack-MountedServer NOTE:Ifyouarereplacingahot-swappableitem,youcanleavetheserveronandexternal...
Page 128
Figure6-4RemovingtheTopCoveronaRack-MountedServer 3.Liftthetopcoverofftheserverchassis. ReplacingtheTopCoveronaRack-MountedServer CAUTION:Secureanywiresorcablesinyourserversotheywillnotgetcutorinterferewith thereplacementofthetopcover. Toreplacethetopcover,followthesesteps: 1.Alignthefrontedgeofthetopcoverwiththealignmentmarkontheopticaldrivebay. Figure6-5AligningtheTopCoveronaRack-MountedServer 2.Graspthebluereleaseleverandslidethecovertowardthefrontoftheserveruntilthelever snapsintoplace....
Page 129
Figure6-6ClosingtheTopCoveronaRack-MountedServer 3.Slidetheserverintotherackenclosureandreconnectthepowerandexternalcables. RemovingandReplacingtheFrontBezelonaRack-MountedServer Youmustremovethefrontbezelfromthechassistogainaccesstothepowersuppliesandoptical drive. RemovingtheFrontBezel Toremovethefrontbezel,followthesesteps: 1.Pressinontheretainingclipslocatedontheright-sideofthefrontpanel. Figure6-7FrontBezelRetainingClip 2.Rotatethefrontpaneloutwardandliftitofftheserverchassis....
Page 130
2.Closethebezelandpushtowardthefrontoftheserveruntilitlocksintoplace. Figure6-8ReplacingtheFrontBezelonaRack-MountedServer AccessingaPedestal-MountServer BoththeHP9000rp3410andtherp3440serversareavailableinapedestalconfigurationorcan beconvertedfromaracktoapedestalconfiguration.Toaccesstheinternalcomponentsona pedestalserver,youmustremovethesideandtopcovers. RemovingtheSideCoversonaPedestal-MountedServer NOTE:Ifyouarereplacingahot-swappableitem,youcanleavetheserveronandexternal...