Page 41
– 41 – Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momentarily or for a specific period of time, using a keypad command. Ask your installer if this has been done in our system. Executing There are several entries that can be entered at the keypad to activate this command: 1. Enter your security code + [0]. The door will unlock for 2 seconds. 2. Enter your security code + [#] + 73, or security code...
Page 42
– 42 – Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by using the #70 command from either a keypad or a telephone keypad (if 4285 or 4286 VIP module is used). Ask your installer if this has been done in your system. To activate relays from a keypad, enter 4-digit security code + [#] +70. Follow the keypad prompts described below. To activate relays using a telephone and 4285 or 4286 VIP module, first...
Page 43
– 43 – Using Schedules Delaying the Closing Time Your system’s programmed schedules may automatically arm the system at a predetermined time. In the event a user must stay on the premises later than usual, users with master or manager authority levels can manually delay the automatic arming (closing) time up to 2 hours. To delay the closing time: 1. Enter your security code (master or manager authority levels only). 2. Press the # key, followed by 82. 3. A menu prompt will be displayed,...
Page 44
– 44 – Using Schedules (cont’d) Programming Temporary Schedules Temporary schedules only affect the partition from which it is entered. Temporary schedules can be reused at later dates simply by scrolling (by pressing #) to the DAYS? prompt (described below) and activating the appropriate days. This should be considered when defining daily time windows. Note that only users with authority level of manager or higher can program temporary schedules. To program temporary schedules: 1. Enter...
Page 45
– 45 – Using Schedules (cont’d) DAYS ? MTWTFSS HIT 0-7 X X This is the prompt that actually activates the temporary schedule, and allows the temporary schedule to be customized to a particular week’s needs. To select the days which are to be activated, enter the desired number 1-7 (Monday = 1). An X will appear under that day, indicating the previously entered schedule for that day is active. Entering a day’s number again will deactivate that day. Pressing 0 will turn all days...
Page 46
– 46 – Programming Device Timers General Information Device timers consist of an ON time & an OFF time, and selected days of the week in which they are active. There are up to 20 timers that can be used to control various devices, such as lights or appliances. Your installer will have programmed the appropriate devices into the system (up to 96 devices can be programmed). Each timer controls a single device (designated as an output number) that you select. For example, timer 1 might be set...
Page 47
– 47 – Programming Device Timers (cont’d) 00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the display shows the desired time, press the * key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication. Enter 00:00 if this timer is not being used to turn something ON for the days selected below. (ex. using one timer to turn lights on one day and using another timer to turn them off on another day). 00 OFF TIME ?...
Page 48
– 48 – Using #77 Instant Activation Mode The #77 Instant Activation Mode is used to activate outputs, bypass zones, etc. immediately upon exiting the #77 Mode. The actions that may be activated are relay commands, arm/disarm commands, zone bypassing commands, and open/close access conditions. Relay Commands Action Code Action Specifier 01 Relay On Relay # 02 Relay Off Relay # 03 Relay Close for 2 seconds Relay # 04 Relay Close XX minutes ✳ Relay # 05 Relay Close YY...
Page 49
– 49 – Using #77 Instant Activation Mode (cont’d) Bypass Commands Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for bypass commands. If 3 (During) is selected for auto-bypassing, the system bypasses the zone(s) specified on a particular zone list at the beginning of the window and unbypasses them at the end of the window. If it is selected for auto unbypassing, the system removes the bypass at the beginning of the window and restores the bypass at the end of...
Page 50
– 50 – Using #77 Instant Activation Mode (cont’d) Additional Commands Action Code Action Specifier 77 Access Point Group Enable Group # 78 Access Point Group Disable Group # To enter the Instant Activation Mode: Enter your security code, then press the [#] key followed by 77. ACTION ? Enter the code for the desired action. The action codes are the events that are to take place when either the system exits the #77 Mode or the scheduled time is reached, depending on the action...