Page 21

Security System Operation (Contd) 
21 
SCREEN ACTION  
4.  Highlight the zone(s) to be bypassed 
by touching it on the screen when the 
zones are displayed. 
 
5.  Press the BYPASS SELECTED 
button.  The User Authorization screen 
is displayed with the instructions To 
Bypass Zones, Enter Code. 
Note: If zones have already been 
bypassed, the top of this screen will 
indicate “Ready Bypass” and the screen 
will contain a Clear Bypasses button. 
6.  Enter your 4-digit user code.  The 
More Choices screen...

Page 22

Security System Operation (contd) 
22 
How to Remove Bypassed Zones 
A bypassed zone will automatically be unbypassed when you disarm 
the system.  If a zone is bypassed, you can remove the bypass as 
follows: 
SCREEN ACTION  
1.  View bypassed zones by pressing the 
SHOW ZONES button.  
While the TouchCenter is requesting and 
receiving the zone data from the control 
panel, the screen displays Please Wait!. 
Then the zones, along with their current 
status, are displayed. 
 
2.  Remove zone bypasses by...

Page 23

Security System Operation (Contd) 
23 
How to Clear a Control Panel Message 
When a Control Panel Message is displayed, the user has two options. 
a) User can clear the Control Panel Message immediately, or b) User 
can minimize the window and clear it at a later time. Refer to the 
section below to Hide the Control Panel Message. 
SCREEN ACTION  
1.  To clear Control Panel Messages, 
press the CLEAR button.  
Not Ready Alarm
To Clear Panel
Messages, Enter
Code
2. Enter your Authorized Code. 
3. Once...

Page 24

Security System Operation (contd) 
24 
How to Disarm the System 
IMPORTANT: If you return and the main burglary sounder is on, 
DO NOT enter the premises, but call the police from a nearby safe 
location. If you return after an alarm has occurred and the main 
sounder has shut itself off, the TouchCenter will beep rapidly upon 
entering, indicating that an alarm has occurred during your absence. 
LEAVE IMMEDIATELY and CONTACT THE POLICE from a 
nearby safe location. 
The system may be disarmed using...

Page 25

Security System Operation (Contd) 
25 
SCREEN ACTION  
2. Enter your 4-digit user code.  
If the Arm Multi-Partitions button on the 
“Arm ed” screen is not checked, the 
TouchCenter beeps once, the system will 
disarm, and the Arming screen is 
displayed showing the system as Ready to 
Arm or Not Ready Fault if any zone is 
faulted (open). 
If the Arm Multi-Partitions button on the 
“Arm ed” screen is checked, the Partition 
No. & Description screen is displayed 
listing the partitions to which you have...

Page 26

Security System Operation (contd) 
26 
How to Check the Status of Other Partitions 
This system supports between one and eight Partitions (depending on 
the system.)  Partitioning enables a single physical alarm system to 
control up to eight areas of protection (partitions) depending on the 
system you have purchased. Each TouchCenter and other keypad is 
assigned a default partition for display purposes, and will show only 
that partitions information.  
Note: A letter “H” following the partition name...

Page 27

Security System Operation (Contd) 
27 
SCREEN   ACTION 
3.  Enter the code authorized to access 
other partition(s).   
If the code is accepted, the system 
displays the partitions that user has 
access to.   
Note:  A code may have access to some 
or all of the available partitions. 
This screen displays the available 
partitions (in this case, Partitions 1 (Main), 
2, and 3), and their current status.   
The current partition is shown at the top of 
the display (in this exam ple, the device is...

Page 28

Security System Operation (contd) 
28 
How to Send Emergency Messages 
 
•  Emergency messages are optional and may not be available on your 
system. Ask your system installer if emergency messages are 
available on your system. 
• The Emergency screen cannot be accessed while running a screen 
diagnostic test or while in the clean screen mode. 
An emergency message for fire, panic, or medical can be sent to the 
central monitoring station from the Emergency screen.  The 
Emergency screen can be accessed...

Page 29

Security System Operation (Contd) 
29 
How to View the Event Log  
Your system has the ability to record various events in a history log 
wherein each event is recorded with the time and date of its 
occurrence.  The control panel must be programmed to record various 
system events in installer programming mode.  
To view the Event Log, perform the following: 
1.  From the Hom e screen, press the SECURITY button.  The Arming screen  
is displayed.
 
SCREEN ACTION  
2.  Press the MORE CHOICES button....

Page 30

 
30 
Fire Alarm System Operation  
Introduction to Fire Alarm System Operation 
Your fire alarm system (if installed) is on 24 hours a day, providing 
continuous protection.  In the event of an emergency, the installed 
smoke and heat detectors will automatically send signals to your 
Control/Communicator, triggering a loud interrupted sound from the 
keypad.  An interrupted sound will also be produced by optional 
exterior sounders.  A FIRE message will appear at your keypad and 
remain on until you...
Start reading Honeywell series TouchCenter Keypads 6271 User Manual

Related Manuals for Honeywell series TouchCenter Keypads 6271 User Manual

All Honeywell manuals