Security System Operation (Contd) 21 SCREEN ACTION 4. Highlight the zone(s) to be bypassed by touching it on the screen when the zones are displayed. 5. Press the BYPASS SELECTED button. The User Authorization screen is displayed with the instructions To Bypass Zones, Enter Code. Note: If zones have already been bypassed, the top of this screen will indicate “Ready Bypass” and the screen will contain a Clear Bypasses button. 6. Enter your 4-digit user code. The More Choices screen is displayed showing the system status as Ready- Bypass 7. Press the BACK button to return to the “Arming” screen.
Security System Operation (contd) 22 How to Remove Bypassed Zones A bypassed zone will automatically be unbypassed when you disarm the system. If a zone is bypassed, you can remove the bypass as follows: SCREEN ACTION 1. View bypassed zones by pressing the SHOW ZONES button. While the TouchCenter is requesting and receiving the zone data from the control panel, the screen displays Please Wait!. Then the zones, along with their current status, are displayed. 2. Remove zone bypasses by pressing the CLEAR BYPASSES button. Note: Bypassed zones are indicated by the Bypass icon . 3. The User Authorization screen is displayed with the instructions To Clear Bypasses, Enter Code. Note: If the system is armed and you unbypass a zone, it will disarm the system. Enter your 4-digit user code. The More Choices screen is displayed showing the system as Ready to Arm. Note: This will not occur if any zone(s) is open (not ready).
Security System Operation (Contd) 23 How to Clear a Control Panel Message When a Control Panel Message is displayed, the user has two options. a) User can clear the Control Panel Message immediately, or b) User can minimize the window and clear it at a later time. Refer to the section below to Hide the Control Panel Message. SCREEN ACTION 1. To clear Control Panel Messages, press the CLEAR button. Not Ready Alarm To Clear Panel Messages, Enter Code 2. Enter your Authorized Code. 3. Once your Authorized Code is accepted, the Control Panel Message will be cleared. If the alarm is still present, press CLEAR again and then enter your Authorized Code again. How to Hide a Control Panel Message When the Control Panel Message is displayed, press the HIDE button to address the condition later. SCREEN ACTION 1. Press the HIDE button to clear the Control Panel Message later.
Security System Operation (contd) 24 How to Disarm the System IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the TouchCenter will beep rapidly upon entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. The system may be disarmed using either of two methods. One method is employed when you enter the premises and the other is when you have been in the premises with the system armed (i.e., Stay and Night arming modes). To disarm the system when entering the premises: The TouchCenter will automatically display the Entry Delay Active screen when you enter the premises: Enter your Code. The partition will be disarmed and the Arming screen is displayed showing the system as Ready to Arm. Note: If you have a comm ercial system and a time window has been defined for when you may disarm the system , the system will not disarm if you are outside that time window. To disarm the system when already in the premises: SCREEN ACTION 1. Press the DISARM button on the Arm ed screen. The User Authorization screen is displayed with the instructions “To Disarm, Enter Code”.
Security System Operation (Contd) 25 SCREEN ACTION 2. Enter your 4-digit user code. If the Arm Multi-Partitions button on the “Arm ed” screen is not checked, the TouchCenter beeps once, the system will disarm, and the Arming screen is displayed showing the system as Ready to Arm or Not Ready Fault if any zone is faulted (open). If the Arm Multi-Partitions button on the “Arm ed” screen is checked, the Partition No. & Description screen is displayed listing the partitions to which you have access. 3. Press the DISARM ALL button if you wish to disarm the system. The TouchCenter beeps once and the Arming screen is displayed showing the system as Ready to Arm or not ready if any zone is faulted (open). Note: If you wish to disarm only selected partitions, you must first highlight the partition(s) to be disarmed, then press the DISARM SELECTED button. The TouchCenter beeps once and the Arming screen is displayed showing the system as Ready to Arm or not ready if any zone is faulted (open). Note: Once the system is disarmed, the TouchCenter will return to the Home screen after the selected “To Home Page After” time has expired. This time is selected on the “Setup” screen.
Security System Operation (contd) 26 How to Check the Status of Other Partitions This system supports between one and eight Partitions (depending on the system.) Partitioning enables a single physical alarm system to control up to eight areas of protection (partitions) depending on the system you have purchased. Each TouchCenter and other keypad is assigned a default partition for display purposes, and will show only that partitions information. Note: A letter “H” following the partition name or number indicates that this is the default partition for the TouchCenter. For example, if your physical site is a four-apartment housing unit, your alarm system may be configured with four partitions. Each apartment’s zones (door, windows, smoke detectors, etc.) are assigned to separate partitions, giving each apartment independent arming/disarming control of its own partition (area). A landlord or manager may be granted access to all partitions, so he/she can control the entire system. If a user is so authorized, a TouchCenter or other keypad in one partition can be used to perform system functions in another partition. (Note that only those partitions authorized and programmed by the installer can be accessed in this manner.) To check the status of other partitions perform the following: 1. From the Hom e screen, press the SECURITY button. The Arming screen is displayed. SCREEN ACTION 2. Press the Current Partition tab (lower edge of the screen; in this case it displays Main H). The User Authorization screen is displayed with the instructions “For Authorized Partitions, Enter Code”.
Security System Operation (Contd) 27 SCREEN ACTION 3. Enter the code authorized to access other partition(s). If the code is accepted, the system displays the partitions that user has access to. Note: A code may have access to some or all of the available partitions. This screen displays the available partitions (in this case, Partitions 1 (Main), 2, and 3), and their current status. The current partition is shown at the top of the display (in this exam ple, the device is attached to Partition 1 (Main H). To change this assignment, select the appropriate button (e.g. press P2 to switch control to Partition 2). Note: After leaving this screen when using a residential panel, the selected partition in the TouchCenter will automatically revert back to the TouchCenter’s home partition after two minutes. When using commercial panels, you must select the TouchCenter’s hom e partition to return to it.
Security System Operation (contd) 28 How to Send Emergency Messages • Emergency messages are optional and may not be available on your system. Ask your system installer if emergency messages are available on your system. • The Emergency screen cannot be accessed while running a screen diagnostic test or while in the clean screen mode. An emergency message for fire, panic, or medical can be sent to the central monitoring station from the Emergency screen. The Emergency screen can be accessed by activating the PANIC Icon located on the lower right corner of the screen. Once the Emergency screen is accessed, perform the following to send an emergency message. SCREEN ACTION On the Emergency screen press and hold (for at least 2 seconds) the associated alarm button for the type of emergency message you want to send (FIRE, PANIC, or MEDICAL). W hen the m essage is sent, the associated Message Sent statem ent is displayed in the text box to the right of the buttons. You are imm ediately returned to the screen from which you pressed the “PANIC” Icon.
Security System Operation (Contd) 29 How to View the Event Log Your system has the ability to record various events in a history log wherein each event is recorded with the time and date of its occurrence. The control panel must be programmed to record various system events in installer programming mode. To view the Event Log, perform the following: 1. From the Hom e screen, press the SECURITY button. The Arming screen is displayed. SCREEN ACTION 2. Press the MORE CHOICES button. The More Choices screen is displayed. 3. Press the EVENT LOGS button on the More Choices screen. The Event Log screen is displayed. Note: While TouchCenter is requesting and receiving the event log data from the control panel, the Event Log screen displays Please Wait!. The first six events will be displayed. To view all item s, press the Show More button and press the up/down arrows to scroll through the event log. Notes: • W hen All Partitions or All Events button is pressed, and more than 100 events exist, the Show More button text will change to read Next>>. If you press the Next>> button, a and and
30 Fire Alarm System Operation Introduction to Fire Alarm System Operation Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency, the installed smoke and heat detectors will automatically send signals to your Control/Communicator, triggering a loud interrupted sound from the keypad. An interrupted sound will also be produced by optional exterior sounders. A FIRE message will appear at your keypad and remain on until you silence the alarm. In Case of Fire Alarm 1. Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest keypad and manually initiate an alarm by pressing the panic key assigned as FIRE emergency (if programmed by the installer) and hold down for at least 2 seconds. 2. Evacuate all occupants from the premises. 3. If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately. Silencing and Clearing a Fire Alarm 1. Silence, acknowledge, and clear the alarm by: a. For Residential Systems: Press “Touch here to Silence” on the display to silence the alarm. For Commercial Systems: Enter your code. This will silence and acknowledge the alarm and disarm the system (if armed). b. Press the CLEAR button followed by your code. This will acknowledge the alarm and disarm the system (if armed). c. Press the DISPLAY FAULTS button on the Arming screen. The faulted fire zone will be displayed. d. Press the CLEAR button and then enter your code. This will clear the Fire Alarm from the system. 2. If the keypad does not indicate a READY condition after the second sequence, press the DISPLAY FAULTS key on the Arming screen to display the zone(s) that are faulted. Be sure to check that smoke detectors are not responding to smoke or heat