RTH2510/RTH2410 9 69-2601ES—01 Save money by setting program schedules It’s easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for weekdays and weekends. Set to the time you awaken and the temperature you want during the morning, until you leave for the day. Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level). Set to the time you return home and the temperature you want during the evening, until bedtime. Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level). WAKE6:00 am 70 ° LEAVE8:00 am 62 ° RETURN6:00 pm 70 ° SLEEP10:00 pm 62 °
Operating Manual 69-2601ES—01 10 About your new thermostatEnergy saving settings for maximum cost savings This thermostat is pre-set to use energy saving program settings. We recommend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to adjust times and temperatures of each time period.) Wake(6:00 am) Leave(8:00 am) Return(6:00 pm) Sleep(10:00 pm) Cool (Mon-Fri)Heat (Mon-Fri)Heat (Sat-Sun)Cool (Sat-Sun) 70 °78 °70 °78 ° 62 °85 °62 °85 ° 70 °78 °70 °78 ° 62 °82 °62 °82 °
RTH2510/RTH2410 11 69-2601ES—01 MoWakeSet Schedule Setam 756: 30 M32704 To adjust program schedules ( RTH2510) 1. Press SET until Set Schedule is displayed. 2. Press s or t to set your Wake time for the day displayed, then press SET. 3. Press s or t to set the temperature for this time period, then press SET. 4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each day’s time period. 5. Press RUN to save & exit. Note: Make sure the thermostat is set to the system you want to program (Heat or Cool). Press SET 3 times, then adjust time. Press SET, then set desired temperature.
Operating Manual 69-2601ES—01 12 Mo Tu We Th Fr W akeSet Schedule Setam 756: 30 M3270 6 To adjust program schedules ( RTH2410) 1. Press SET until Set Schedule is displayed. 2. Press s or t to set your weekday Wake time (Mo-Fr), then press SET. 3. Press s or t to set the temperature for this time period, then press SET. 4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period. 5. Press SET to set weekend time periods (Sa & Su), then press RUN to save & exit. Note: Make sure the thermostat is set to the system you want to program (Heat or Cool). Press SET 3 times, then adjust time. Press SET, then set desired temperature.
RTH2510/RTH2410 13 69-2601ES—01 About your new thermostat Temporary Wa ke Setam 706: 30 M32708 Setam 756 : 30 M3270 9 Program schedule override (temporary) Press s or t to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. “Temporary” will appear on the display and the current program period will flash. The new temperature will be maintained only until the next programmed time period begins (see page 9). To cancel the temporary setting at any time, press RUN. Press to temporarily adjust temperature. Press to cancel temporary setting and resume program schedule. Note: Make sure the thermostat is set to the system you want to control (heat or cool).
Operating Manual 69-2601ES—01 14 About your new thermostat Hold Setam 706 : 30 M32710 Setam 756 : 30 M3270 9 Program schedule override (permanent) Note: Make sure the thermostat is set to the system you want to control (heat or cool). Press to permanently adjust temperature.Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods. The “Hold” feature turns off the program schedule and allows you to adjust the thermostat manually, as needed. Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press RUN to cancel “Hold” and resume the program schedule. Press to cancel “Hold” setting and resume program schedule.
RTH2510/RTH2410 15 69-2601ES—01 About your new thermostatBuilt-in compressor protection This feature helps prevent damage to the compressor in your air conditioning or heat pump system. Damage can occur if the compressor is restarted too soon after shutdown. This fea- ture forces the compressor to wait 5 minutes before restarting. During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). When the safe wait time has elapsed, the message stops flashing and the compressor turns on. Message flashes until safe restart time has elapsed. We Wake am Cool 75 On 6: 30 M3271 1
Operating Manual 69-2601ES—01 16 About your new thermostat Early Start : This feature allows the heating or cooling to turn on before the program start time, so the temperature is reached at the time you set. For example: Set the Wake time to 6 am, and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6. The next time period is displayed when the system is activated before a scheduled time period. Early Start We Wake am Cool 75 On 6: 30 M32712
RTH2510/RTH2410 17 69-2601ES—01 Battery replacement Install two fresh AAA batteries when Lo Batt flashes on the screen. Lo Batt appears for 60 days before the batteries are depleted. Replace batteries once a year, or when you will be away for more than a month. Most settings are stored in non- volatile (permanent) memory. Only the clock and the day must be set after you replace the batteries. Pull at bottom to remove thermostat from wallplate. Turn thermostat over, insert fresh AAA alkaline batteries, then reinstall thermostat. Set the System switch to Off before removing the batteries. Otherwise, the heating/cooling system could remain activated even when batteries are removed. RTHXXXX M32707 W/ Au x No t Used Heat Off CoolAuto OnFan M32705
Operating Manual 69-2601ES—01 18 RTHXXXX M32707 W/ Au x No t Used Heat Off CoolAuto OnFan M32705 Customer assistance For assistance with this product, please visit http://yourhome.honeywell.com. Or call Honeywell Customer Care toll-free at 1-800-468-1502. To save time, please note your model number and date code before calling.Turn thermostat over to find model number and date code. Pull at bottom to remove thermostat from wallplate.