Operating Manual RTH2510/RTH2410 Series Programmable Thermostat 69-2601ES-01
Read and save these instructions. Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 ® U.S. Registered Trademark. Patents pending. Copyright © 2011 Honeywell International Inc. All rights reser ved. This manual covers the following models: RTH2510 R T H 2 410 CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
RTH2510/RTH2410 1 69-2601ES—01 About your new thermostatThermostat features ...................................2Thermostat is preset, ready to go .............3Quick reference to controls .......................4Quick reference to display ........................5 Programming & Operation Set time and day ........................................6Select system setting ................................7Select fan setting .......................................8Using program schedules ...................9–10Adjust program schedule (RTH2510) ......11Adjust program schedule (RTH2410) ......12Program schedule overrides .............13–14Compressor protection ............................15Early Start .................................................16 AppendicesBattery replacement ................................17Customer assistance ...............................18In case of difficulty.............................19–20Limited warranty ......................................21 This thermostat is ready to go ! Your new thermostat is pre-programmed and ready to go. See page 10 to check settings. Table of contents
About your new thermostat Your new Honeywell thermostat has been designed to give you many years o\ f reliable service and easy-to-use, push-button climate control. Features • Backlit display is easy to read • Displays ambient (measured) temperature at all times • One-touch access to setpoint temperature • Preset program settings • Temporary and permanent override of schedule • Early start ensures the right temperature at the right time • Built-in compressor protection Operating Manual 2
RTH2510/RTH2410 3 69-2601ES—01 This thermostat is ready to go! Your new thermostat is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed: 1. Set time and day (required for proper operation) .........................See page 6 2. Select system setting: Preset to Off ................................To change, see page 7 3. Select fan setting: Preset to Auto ...................................To change, see page 8 4. Program schedules: Preset to energy-saving levels while you’re at work or asleep ....................................To change, see pages 9-12 ONE-TOUCH TEMP CONTROL : You can override the program schedule at any time, and manually adjust the temperature (see pages 13-14).
Operating Manual 69-2601ES—01 4 M32700Heat Off CoolAuto OnFan Quick reference to controls Temperature adjustment (see page 13-14) Screen Lit for 12 seconds when you press any button. Fan Switch (see page 8)On: Fan runs continuously.Auto: Fan runs only when heating or cooling system is on. Set: Press to set time/day/schedule. Hold: Press to override programmed tempera-ture control. Run: Press to resume program schedule. System switch (see page 7)• Heat: Heating system control.• Off: All systems off. • Cool: Cooling system control.
RTH2510/RTH2410 5 69-2601ES—01 M32701 We LoBatt Wake Setam Heat 75 On 6: 30 Quick reference to display screen Low battery warning (see page 17)Setpoint indicator Appears when the setpoint temperature is displayed. Temperature The ambient (measured) temperature is normally displayed. To view the setpoint temperature, press the Up or Down button once. The setpoint temperature will appear for five seconds. System status Cool on: Cooling system is on. Heat on: Heating system is on. Aux On: Auxiliary heat is activated. When Heat On or Cool On is flashing, compressor protection is engaged (see page 15). Current day/time (see page 6) Current program period Wake/Leave/Return/Sleep (see pages 9-10)
Operating Manual 69-2601ES—01 6 Set Time am6: 30 M32702 Set Day We M32703 Set the time and day 1. Press the SET button, then press s or t to set the clock time. 2. Press the SET button, then press s or t to select the day of the week. 3. Press RUN to save & exit. Note: If the clock flashes, the thermostat will follow your settings for the Monday “Wake” time period until you reset the time and day. Press SET, then adjust time. Press SET, then select current day.
RTH2510/RTH2410 7 69-2601ES—01 M32700Heat Off CoolAuto OnFan Select the system setting The SYSTEM switch can be set to control your heating or cooling system, depend- ing on the season. • Cool: Cooling system control. • Off: All systems are off. • Heat: Heating system control. Set SYSTEM switch to control the heating or cooling system. CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
Operating Manual 69-2601ES—01 8 Select the fan setting Set the FAN switch to Auto or On. In “Auto” mode (the most commonly used setting), the fan runs only when the heat- ing or cooling system is on. If set to “On,” the fan runs continuously. Set FAN switch to choose whether the fan runs continuously or only as needed. M32700Heat Off CoolAuto OnFan