    							Application
    This thermostat can be used to control an electric heating system such as a baseboard heater or a convector.
    The thermostat CANNOT be used with:
    • a resistive load under 0.83 A• a resistive load over 8.3 A• a system driven by a contactor or a relay (inductive load)• a fan-forced heating system (e.g. : fan-forced convector)• a central heating system.
    WARNING Electrical Shock Hazard.
    This thermostat is a line voltage control (120–240 Volts). Do not install it if you are not completely familiar with house wiring. If handled improperly, there is risk of electric shock hazard, which may cause serious injury or death.
    Do you need assistance? We are here to help.
    Call 1-800-468-1502 for wiring assistance before returning the 
    thermostat to the store.
    O
    Read and save these 
    instructions.
    For help please visit  yourhome.honeywell.com
    R  No
    T  
    						
    							2
    ATTENTION: MERCURY RECYCLING NOTICE
    This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash.
    For more information on how and where to properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation at  www.thermostat-recycle.org.
    For mercury thermostat recycling in Canada, please refer to Switch the Stat at  www.switchthestat.ca
    NO MERCURY
    Hg
    SUPPLIED PARTS• One (1) thermostat• Two (2) 6-32 mounting screws• Two (2) solderless connectors
    Temperature display and setting
    Up button
    Down button
    Appears when the 
    setpoint is displayed
    Temperature display
    Heating intensity 
    indicator 
    (No image appears 
    when heating is off.)
    The thermostat normally displays the actual (ambient) temperature.
    • To view the setpoint temperature, briefly press the Up or Down button. The setpoint will be displayed for 5 seconds. • To change the setpoint temperature, press the Up or Down button until the 
    desired value is displayed. 
    						
    							3
    Removing the faceplate
    WARNING 
    TURN OFF POWER TO THE 
    HEATING SYSTEM AT THE 
    MAIN POWER PANEL TO 
    AVOID ELECTRIC SHOCK.
    Loosen the screw holding the faceplate to the base. The screw cannot be completely removed and remains captive on the base. Remove the faceplate from the base by pulling the bottom half.
    4-wire Installation2-wire Installation
    Wiring
    Connect either one of the thermostat wires to the heater wire and the other one to the power supply wire using solderless connectors for copper wires.
    NOTE: All cables and connections must conform to the local electrical code. Special CO/ALR solderless connectors must be used when connecting with aluminium conductors.
    Power supply
    Power supply 
    						
    							4
    Installing the faceplate
    Install the base onto an electrical box.
    Reinstall the faceplate on the base and secure it in place with the screw.
    Selecting the temperature display format
    To select the temperature display format:
    1. Press the Up and Down buttons for three seconds. The format currently used will be indicated on the screen.2. Press the Up or Down button to change the format.3. Press the Up and Down buttons for one second (or wait for one minute) to return to the normal display.
    NOTE: Keep the air vents of thermostat clean and unobstructed at all times.
    Troubleshooting
    ProblemSolution(s)
    Thermostat is hot.This is normal.
    Displayed temperature is wrong.Remediate if any the following conditions exists:• The thermostat is exposed to air draft.• The sticker on the thermostat’s screen has not been removed.• The thermostat is located near or above a heat source such as a light dimmer.
    Display disappears and 
    reappears after a few minutes.
    The thermal protection device on the heater has temporarily opened. This can happen if the heater is obstructed by furniture or curtain and has overheated, or if the heater’s thermal protection device is too sensitive. 
    						
    							5
    Specifications
    Supply: 120/240 VAC, 60 Hz
    Minimum load:  0.83 A (resistive only)
     200 W @ 240 V AC
     100 W @ 120 V AC
    Maximum load:  8.3 A (resistive only)
      2000 W @ 240 VAC
     1000 W @ 120 VAC
    Display range: 0 °C to 50 °C (32 °F to 99 °F)
    Setpoint range: 5 °C to 30 °C (40 °F to 85 °F)
    Storage: -20 °C to 50 °C (-4 °F to 120 °F)
    Heating cycle length: 15 seconds
    Permanent memory: You do not need to adjust the temperature following a power outage. 
    						
    							1-year limited warranty
    Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).
    If the product is defective,
    (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or
    (ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.
    This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Hon\
    eywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
    Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY IN\
    CIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation ma\
    y not apply to you.
    THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY.
    Some states do not allow limitations on how long an implied warranty las\
    ts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have oth\
    er rights which vary from state to state.
    If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.
    Automation and Control Solutions 
    Honeywell Inter 
    1985 Douglas Drive Nor 
    Golden V 
    yourhome.honeywell.com
    \256 U\251 23P33-00149EF-01  
    						
    							Application
    Ce thermostat a été conçu pour commander un appareil de chauffage électrique tel qu’une plinthe chauffante ou un convecteur.
    Ce thermostat NE PEUT être utilisé avec :
    • une charge résistive inférieure à 0,83 A• une charge résistive supérieure à 8,3 A• un appareil muni d’un contacteur ou d’un relais (charge inductive)• un appareil muni d’un ventilateur (exemple : ventiloconvecteur)• un système de chauffage central
    MISE EN GARDE : Risque de chocs électriques.
    Ne pas installer ce régulateur tension secteur (tension secteur de 1\
    20 V à 140 V) à moins d’être très familier avec les raccordements électriques et l’installation des régulateurs tension secteur. Une mauvaise manipulation lors de l’installation peut causer des blessures graves ou la mort. 
    Besoin d’aide? Nous sommes à votre service.
    Composer le 1-800-468-1502 pour obtenir de l’aide au raccordement avant de retourner le thermostat au magasin.
    R LV 3 12 0    
    Veuillez lire le mode 
    d’emploi et le conserver en 
    li e u  s
    						
    							8
    ATTENTION: AVIS RELATIF AU RECYCLAGE DU MERCURE 
    Ce produit ne contient aucun mercure. Cependant, ce produit peut remplacer un produit qui contient du mercure. Le mercure et les produits contenant du mercure ne doivent pas être jetés aux ordures ménagères.
    Pour obtenir plus d›informations pour savoir comment et où recycler adéquatement un thermostat contenant du mercure aux États-Unis, consultez l›organisme de recyclage des thermostats (Thermostat Recycling Corporation) à www.thermostat-recycle.org.
    Pour le recyclage de thermostats contenant du mercure au Canada, consultez l›organisme  Switch the Stat à www.switchthestat.ca
    NO MERCURY
    NE PAS JETER
    LE MERCURE
    Hg
    PIÈCES FOURNIES• Un (1) thermostat• Deux (2) vis de montage 6-32• Deux (2) connecteurs sans soudure
    Affichage et réglage de la température
    Bouton Haut
    Bouton Bas
    Apparaît lorsque la température de consigne est affichée
    Affichage de la température
    Indicateur de l’intensité du chauffage. (L’absence de l’image indique l’arrêt du chauffage.)
    Le thermostat affiche normalement la température mesurée (ambiante).
    • Pour afficher la température de consigne, appuyer brièvement sur le bouton Haut ou Bas. La température de consigne sera affichée pendant 5 secondes.• Pour modifier la température, appuyer sur le bouton Haut ou Bas jusqu’à ce 
    que la valeur désirée apparaisse. 
    						
    							9
    Enlever la façade
    AVERTISSEMENT 
    METTRE LE SYSTÈME 
    DE CHAUFFAGE HORS 
    TENSION AFIN D’ÉVITER 
    TOUT RISQUE DE CHOC 
    ÉLECTRIQUE.
    Desserrer la vis qui retient la façade du thermostat à la base. La vis ne peut être complètement enlevée et reste captive sur la base. Séparer la façade de la base en tirant sur la partie inférieure du thermostat.
    4-wire Installation2-wire Installation
    Câblage
    Relier n’importe quel fil du thermostat au fil de l’appareil de chauffage (charge) et l’autre fil au fil de l’alimentation en utilisant des connecteurs sans soud\
    ure pour fils de cuivre.
    REMARQUE : Tous les câbles et les raccordements doivent être conformes au code d’électricité local. Pour le raccordement à des fils en aluminium, employer des connecteurs identifiés CO/ ALR.
    Power supply
    Power supply 
    						
    							10
    Installer la façade
    Installer la base sur une boîte électrique.
    Remettre la façade du thermostat sur la base et resserrer la vis.
    Selectionner le format d’affichage de la température
    Pour selectionner le format d’affichage de la température :
    1. Appuyer sur les boutons Haut et Bas pendant trois secondes.  Le format utilisé sera indiqué à l’écran.2. Appuyer sur le bouton Haut ou Bas pour changer le format.3. Appuyer sur les boutons Haut et Bas pendant une seconde (ou attendre une minute) pour retourner à l’affichage normal.
    REMARQUE : Garder les ouvertures d’aération du thermostat propres et dégagées en tout temps.
    Dépannage
    PROBLÈMESSOLUTIONS
    Le thermostat est chaud.Ceci est normal.
    La température affichée est erronée.Remédier si l’une des conditions suivantes existe :• Il y a un courant d’air à proximité.• L’autocollant sur l’écran du thermostat n’a pas été enlevé.• Le thermostat est situé près ou au-dessus d’une source de chaleur tel qu’un gradateur de lumière.
    L’affichage disparaît et 
    ne réapparaît qu’après quelques minutes.
    La protection thermique de la plinthe était temporairement ouverte. Ceci peut se produire suite à une surchauffe lorsque la plinthe est obstruée par un meuble ou un rideau, ou si la protection thermique de la plinthe est trop sensible. 
    						