Home > Honeywell > Thermostat > Honeywell Magicstat 1 Manual

Honeywell Magicstat 1 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell Magicstat 1 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							RTH6350/RTH6450 Series
     9 69-2415ES—03
    Save money by setting program schedules
    It’s easy to program your system for maximum energy savings. You can program four 
    time periods each day, with different settings for weekdays, Saturday and Sunday.
    Set to the time you awaken and the temperature you want 
    during the morning, until you leave for the day.
    Set to the time you leave home and the temperature you 
    want while you are away (usually an energy-saving level).
    Set to the time you return home and the temperature you 
    want during the evening, until bedtime.
    Set to the time you go to bed and the temperature you want 
    overnight (usually an energy-saving level).
    WAKE6:00 am
    70 °
    LEAVE8:00 am
    62 °
    RETURN6:00 pm
    70 °
    SLEEP10:00 pm
    62 ° 
    						
    							Operating Manual
    69-2415ES—03 10
    Energy-saving settings for maximum cost savings
    This thermostat is pre-set with energy-saving program settings. We recommend these 
    settings, since they can reduce your heating/cooling expenses by as much as 33%. 
    (See next page to adjust times and temperatures of each time period.)
    Wake(6:00 am)
    Leave(8:00 am)
    Return(6:00 pm)
    Sleep(10:00 pm)
    Cool (Mon-Fri)Heat (Mon-Fri)Heat (Sat-Sun)Cool (Sat-Sun)
    70 °75 °70 °75 °
    62 °83 °62 °
    [Or	cancel	 period]83 ° 
    [Or	cancel	 period]
    70 °75 °70 °
    [Or	cancel	 period]75 °
    [Or	cancel	 period]
    62 °78 °62 °78 ° 
    						
    							RTH6350/RTH6450 Series
     11 69-2415ES—03
    To adjust program schedules ( RTH6350 only)
    1. Press SET CLOCK/DAY/SCHEDULE\X, then SET SCHEDULE.
    2. Press s or t to set your weekday Wake time (Mon–Fri), then press NEXT.
    3. Press s or t to set the temperature for this time period, then press NEXT.
    4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
    5. Press NEXT to set weekend time periods (Sat-Sun), then press DONE to save & exit.
    Note: Make sure the thermostat is set to the system you want to program (Heat or Cool).
    Note: You can press CANCEL \fERIOD to eliminate unwanted time periods (except Wake).M28409
    Set  Clock/Day /
    Schedul eAuto
    Fan
    System
    Heat
    Set  Day Set Schedul e
    Done
    Mon 
    Tue  We d Thu Fri
    Leav e
    Set Schedule
    Heat
    Setting
    AM
    628 :
    00
    DoneCancelPeriodNext 
    						
    							Operating Manual
    69-2415ES—03 12
    About your new thermostatTo adjust program schedules ( RTH6450 only)
    1. Press SET CLOCK/DAY/SCHEDULE\X, then SET SCHEDULE.
    2. Press s or t to set your weekday Wake time (Mon–Fri), then press NEXT.
    3. Press s or t to set the temperature for this time period, then press NEXT.
    4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
    5. Press NEXT to set Saturday time periods.
    6. Press NEXT to set Sunday time periods, then press DONE to save & exit.
    Note: Make sure the thermostat is set to the system you want to program (Heat or Cool).
    Note: You can press CANCEL \fERIOD to eliminate unwanted time periods (except Wake).M28409
    Set  Clock/Day /
    Schedul eAuto
    Fan
    System
    Heat
    Set  Day Set Schedul e
    Done
    Mon 
    Tue  We d Thu Fri
    Leav e
    Set Schedule
    Heat
    Setting
    AM
    628 :
    00
    DoneCancelPeriodNext 
    						
    							RTH6350/RTH6450 Series
     13 69-2415ES—03
    About your new thermostat
    M28410
    Heat
    Setting
    Inside
    AM
    69756:
    30
    Te mporary
    Run Schedule
    Auto
    Fan
    System
    Heat
    Program schedule override (temporary)
    Press s or t to immediately adjust 
    the temperature. This will temporarily 
    override the temperature setting for the 
    current time period.
    The new temperature will be 
    maintained only until the next 
    programmed time period begins (see 
    page 10). For example, if you want to 
    turn up the heat early in the morning, it 
    will automatically be lowered when you 
    leave for the day.
    To cancel the temporary setting at any 
    time, press RUN SCHEDULE.
    Press to cancel temporary setting and resume program schedule.
    Note: Make sure the thermostat is set to the system you want to control (heat or cool).
    Press to temporarily adjust temperature. 
    						
    							Operating Manual
    69-2415ES—03 14
    About your new thermostat
    M28411
    Heat
    Setting
    Inside
    AM
    69756:
    30
    Run Schedule
    Auto
    Fan
    System
    Heat
    Hold
    Program schedule override (permanent)
    Press HOLD to permanently adjust 
    the temperature. This will override 
    the temperature settings for all time 
    periods.
    The	 “Hold”	 feature	 turns	off	the	
    program schedule and allows you 
    to adjust the thermostat manually, 
    as needed.
    Whatever temperature you set will 
    be maintained 24 hours a day until 
    you manually change it, or press 
    RUN SCHEDULE	to	 cancel	 “Hold”	 and	
    resume the programmed schedule.
    Press	to	cancel	 “Hold”	 setting	and resume program schedule.
    Note: Make sure the thermostat is set to the system you want to control (heat or cool).
    Press to permanently adjust temperature. 
    						
    							RTH6350/RTH6450 Series
     15 69-2415ES—03
    About your new thermostat
    Use this feature in climates where both air conditioning and heating are used on the 
    same day. When the system mode is in Auto, the thermostat automatically selects \
    heating or cooling depending on the indoor temperature.
    While in the Auto mode, if a schedule override takes place (temporarily\
     or perma-
    nently) the thermostat will automatically adjust the cooling and heatin\
    g settings to 
    maintain a 3-degree separation between the cool and heat settings.
    For example, if the heat temperature is raised to where it gets within 3-dgrees of the 
    cool	setting,	 the	display	 will	show	 an	up	 arrow	 next	to	“cool”	 to	show	 the	thermostat	
    is raising the cool setting up to maintain a 3-dgreee separation.
    Press the Select Heat/Cool button to select between the heat and cool to v\
    iew/adjust 
    either mode.
    Auto Changeover (RTH6450 only) 
    						
    							Operating Manual
    69-2415ES—03 16
    About your new thermostat
    If the cool temperature is lowered to where it gets close to the heat setting, an arrow 
    next to heat will show the thermostat is lowering the heat setting down \
    to maintain a 
    3-degree separation.
    Auto Changeover (RTH6450 only)
    CAUTION: To avoid possible compressor damage, do not use Auto 
    Changeover if the outside temperature drops below 50ºF (10ºC).
    Run Schedule
    Auto Cool
    Fan Select
    Heat/Coo l
    Heat
    Setting
    Inside
    PM
    73731:
    05
    Te mporary
    M27477
    Press Select Heat/Cool to set the heat or cool temperature.
    The triangle indicates the cool temperature is increasing to maintain 3 degrees between heat and cool settings. 
    						
    							RTH6350/RTH6450 Series
     17 69-2415ES—03
    About your new thermostat
    M28412
     
    Cool On Coo
    l
    Setting
    Inside
    AM75756:
    30
    Set  Clock/Day/
    Schedule Auto
    Fan
    System
    Cool
    Built-in compressor protection
    This feature helps prevent damage to the 
    compressor in your air conditioning or heat 
    pump system.
    Damage can occur if the compressor is 
    re-started too soon after shutdown. This 
    feature forces the compressor to wait a few 
    minutes before restarting.
    During the wait time, the display will flash 
    the message Cool	On (or Heat	 On if you have 
    a heat pump). When the safe wait time has 
    elapsed, the message stops flashing and the 
    compressor turns on.
    Message flashes until safe restart time has elapsed. 
    						
    							Operating Manual
    69-2415ES—03 18
    About your new thermostat
    Smart Response® Technology: This feature 
    allows	the	thermostat	 to	“learn”	 how	long	
    the furnace and air conditioner take to reach 
    programmed temperature settings, so the 
    temperature is reached at the time you set. 
    For example: Set the Wake time to 6 am, and 
    the temperature to 70°. The heat will come 
    on before 6 am, so the temperature is 70° 
    by	the	 time	 you	wake	 at	6.	The	 message	 “In	
    Recovery”	 is	displayed	 when	the	system	 is	
    activated before a scheduled time period.
    Smart Response® Technology
    M27476
     
    Cool On Coo
    l
    Setting
    Inside
    AM75756:
    38
    Set  Clock/Day/
    Schedule Auto
    Fan
    System
    Cool
    In Recovery
    Displays when Smart Response is active. 
    						
    All Honeywell manuals Comments (0)