    							Galaxy 3 Series Programming Manual
    B-3
    Event Codes (cont’d)
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    ATM-1- ATM-1 zone restored ZONE 3.24 HOURS 133
    18.ZN RESTO
    ATM-2- ATM-2 zone restored ZONE 3.24 HOURS 133
    18.ZN RESTO
    ATM-3- ATM-3 zone restored ZONE 3.24 HOURS 133
    18.ZN RESTO
    ATM-4- ATM-4 zone alarm ZONE 3.24 HOURS 133
    18.ZN RESTO
    ALARM EXT- Alarm extend zone rest. ZONE 3.24 HOURS 130
    18.ZN RESTO
    T/0 BURGL- Entry timeout restore ZONE 2.INTRUDE 134
    18.ZN RESTO
    BT Burg. Trouble LOW RES+ Low resistance on zoneZONE15.TROUBL 380
    HIGH RES+High resistance on zoneZONE15.TROUBL 380
    RF SUPER+ RF Supervision Failure ZONE 15.TROUBL 381
    MASKED Zone masked ZONE 15.TROUBLE 380
    BU Burg Unbypass GRP OMIT-Group unomitted USER8.OMIT 574
    OMIT-ATM1- Unomit ATM-1 zone EVENT8.OMIT 572
    OMIT-ATM2- Unomit ATM-2 zone EVENT8.OMIT 572
    OMIT-ATM3- Unomit ATM-3 zone EVENT8.OMIT 572
    OMIT-ATM4- Unomit ATM-4 zone EVENT8.OMIT 572
    FORCE OMT-Unomitted after rearmZONE 8.OMIT 5 7 3
    B V Burg ConfirmCONFIRM 2  independant alarmsEVENT 2.INTRUDENone
    B X EXITExit zone testedZONE NOT SENT 611
    INTRUDER Intruder zone tested ZONE NOT SENT 611
    24 HOURS 24 hour zone tested ZONE NOT SENT 611
    SECURITY Security zone tested ZONE NOT SENT 611
    DUAL Dual zone tested ZONE NOT SENT 611
    ENTRY Entry zone tested ZONE NOT SENT 611
    PUSH SET Push set zone tested ZONE NOT SENT 611
    KEYSWITCHKeyswitch zone tested ZONE NOT SENT 611
    SEC FINAL Secure final zone test. ZONE NOT SENT 611
    PRT FINAL Part final zone tested ZONE NOT SENT 611
    PRT ENTRY Part entry zone tested ZONE NOT SENT 611
    PA PA zone tested ZONE NOT SENT 611
    PA SILENT PA silent zone tested ZONE NOT SENT 611
    PA DELAY PA delay zone tested ZONE NOT SENT 611
    PA DEL/SL PA delay sil zone tested ZONE NOT SENT 611
    LINK Link zone tested ZONE NOT SENT 611
    SPARESpare zone tested ZONE NOT SENT 611
    TAMPER Tamper zone tested ZONE NOT SENT 611
    BELL TAMP Bell tamper zone tested ZONE NOT SENT 611
    BEAM PAIR Beam pair zone tested ZONE NOT SENT 611
    BATT LOW Battery Low zone tested ZONE NOT SENT 611
    LINE FAIL Line fail zone tested ZONE NOT SENT 611
    AC FAIL AC fail zone tested ZONE NOT SENT 611
    LOG Log zone tested ZONE NOT SENT 611
    RM ACCESS Rem acc zone tested ZONE NOT SENT 611 
    						
    							Galaxy 3 Series Programming Manual
    B-4
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    VIDEO Video zone tested ZONE NOT SENT 611
    VIDEO EXT Video exit zone tested ZONE NOT SENT 611
    INT DELAY Intrud delay zone tested ZONE NOT SENT 611
    SEC DELAY Security del zone tested ZONE NOT SENT 611
    SET LOG Set Log zone tested ZONE NOT SENT 611
    CUSTOM A Custom A zone tested ZONE NOT SENT 611
    CUSTOM B Custom B zone tested ZONE NOT SENT 611
    EXITGUARDExitguard zone tested ZONE NOT SENT 611
    MASKMask zone tested ZONE NOT SENT 611
    URGENT Urgent zone tested ZONE NOT SENT 611
    PA UNSET PA unset zone tested ZONE NOT SENT 611
    KSW RESET Ksw. reset zone tested ZONE NOT SENT 611
    VIBRATIONVibration zone tested ZONE NOT SENT 611
    ATM-1 ATM-1 zone tested ZONE NOT SENT 611
    ATM-2 ATM-2 zone tested ZONE NOT SENT 611
    ATM-3 ATM-3 zone tested ZONE NOT SENT 611
    ATM-4 ATM-4 zone tested ZONE NOT SENT 611
    ALARM EXT Alarm extend zone test. ZONE NOT SENT 611
    SOAK TEST Soak test zone act ZONE NOT SENT 611
    C - Closing
    CA Closing Report FULL SETAutomatic Set EVENT10.SETTING 401
    CE Closing ExtendEXTENSION Auto arm exten. delayUSER 10.SETTING 464
    PREWARN Auto arm prewarn delayMISC NEVER TR 464
    CG Close Area PART SET Part set by userUSER 10.SETTING 441
    KSW P/SET Part set by userKSSET 10.SETTING 442
    CI Fail to Set FAIL SET Fail to Set EVENT 7. SET FAULT 454
    CJ Late to Set LATE SETLate to SetEVENT 10.SETTING 454
    CL Closing Report FULL SETFull set USER 10.SETTING 401
    FULL SET Set by keypad EVENT 10.SETTING 401
    KSW SET Keyswitch  setZONE 10.SETTING 409
    CP Auto. Closing REARM Rearm after alarm EVENT10.SETTING 463
    CR Recent Close RECEN.SETPrevious alarm was within 5 mins of set EVENT 2.INTRUDER 459
    CT Late to OpenTIMEOUT Entry timeout EVENT10.SETTING None
    D - Access
    DD Acces Denied Invalid Card MAX tag unknown MOD.17.MAXTAG 421
    DF  Door Forced MAX ALARMDoor contact brokenMOD. 4.SECURITY 423
    17.MAXTAG
    DG  Acces Granted LEGAL CD Legal code entered USER 16.LOG 462
    LEGAL CD ATM code entered USER 16.LOG 462
    Valid MAX tag acceptedUSER 17.MAXTAG 422
    DK Acces  Lockout ILL-CODE Illegal code entry USER 16.LOG 421
    REJECT CARD Illegal MAX tag USER17.MAXTAG 421
    FOB REJECT Illegal FobZONE 10.SETTING 421
    DT Door propped DOOR PROP MAX - Door left openMOD. 4.SECURITY 426
    Event Codes (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    B-5
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    E - System Trouble
    ER Mod Removed REMOVED Module Removed MOD TAMPER 532
    ET RF NVM Fail RF MEM! RF NVM RAM Fail MOD TAMPER 333
    F - Fire
    FA Fire Alarm FIRE+ Fire zone alarm ZONE 6.FIRE 110
    FB Fire Bypass OMITTED Fire zone ommitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    FJ Fire Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
    FR Fire Restoral FIRE- Fire zone restored ZONE6.FIRE 110
    18.ZN RESTO
    FT Fire Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    FU Fire Unbypass FORCE OMT- Unomitted after rearm ZONE8.OMIT 573
    FX Fire Test FIRE Fire zone tested ZONE NOT SENT None
    SOAK TEST Soak test fire zone act ZONE NOT SENT None
    G - Gas (Custom SIA - See Note 2)
    GA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
    GB Bypass OMITTEDzone ommitted ZONE8.OMIT Note 1
    FORCEOMT+ Force omit after rearm ZONE8.OMIT Note 1
    GJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL Note 1
    HIGH RES- Restor zone resistance ZONE 15.TROUBL Note 1
    GR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
    18.ZN RESTO
    GT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL Note 1
    HIGH RES+ High resistance on zone ZONE 15.TROUBL Note 1
    GU Unbypass FORCE OMT- Unomitted after rearmZONE 8.OMIT Note 1
    H - Holdup
    HA Holdup Alarm PA SILENT+ PA Silent zone alarmZONE 1.PA/DURE 122
    PA DEL/SL+ PA Delay Sil.zone alarm ZONE 1.PA/DURE 122
    DURESS Duress with codeUSER 1.PA/DURE 121
    PA UNSET+ PA Unset zone alarm ZONE 1.PA/DURE 122
    HB Holdup Bypass OMITTED Holdup zone omitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    HJ Hold Troub rest LOW RES- Restor zone  resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone  resistance ZONE 15.TROUBL 380
    HR Hold Restoral PA SILENT-PA Silent zone restoredZONE 1.PA/DURE 122
    18.ZN RESTO
    PA DEL/SL- PA Delay Sil.zone rest. ZONE 1.PA/DURE 122
    18.ZN RESTO
    PA UNSET- PA Unset zone restored ZONE 1.PA/DURE 122
    18.ZN RESTO
    HT Holdup Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    HU Hold Unbypass FORCE OMT- Unomitted after rearm ZONE8.OMIT 573
    Event Codes (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    B-6
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    J - Wrong code, Time changed
    JA Code Tamper WRONG CD Wrong code alarm act.MOD. 9.TAMPER 461
    Invalid Code INVALID CD Invalid Code entered MOD. ALWAYS TR None
    JL LOG 90%MISCAlways TR 632
    JR TIMER A MISC NONE 0
    TIMER B MISC NONE 0
    AUTOTIMER MISC NONE 0
    LOCKTIMER MISC NONE 0
    JT Time changed NEW T/D Time/Date modified USER ALWAYS TR
    3625
    K - Heat (Custom SIA - See Note 2)
    KA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
    KB Bypass OMITTEDzone ommitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    KJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
    KR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
    18.ZN RESTO
    KT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    KU Unbypass FORCE OMT-Unomitted after rearmZONE 8.OMIT 573
    L - Phone, Program
    LB Program  begin ENGINEER+ Engineer mode enteredMISC ALWAYS TR 627
    TEST O/P USER NONE 0
    FULL TEST SET NONE 0
    MOD T/D USER NONE 0
    MOD CODES USER NONE 0
    MOD REM USER NONE 0
    OMIT ZONE USER NONE 0
    ENG PARAM USER NONE 0
    ENG ZONES USER NONE 0
    ENG O/PS USER NONE 0
    ENG LINKS USER NONE 0
    ENG SOAK USER NONE 0
    ENG DIGI USER NONE 0
    ENG PRINT USER NONE 0
    ENG QUICK USER NONE 0
    ENG DIAG USER NONE 0
    ENG GROUP USER NONE 0
    ENG ASSEM USER NONE 0
    ENG TMRS USER NONE 0
    ENG CHECK USER NONE 0
    LR Line Restore LINE FAIL-Zone Tel line fail rest. ZONE 12.MD/COM 351
    LINE FAIL-Module Tel line fail rest.MOD 12.MD/COM 351
    LT Line Trouble LINE FAIL+ Zone Tel line fail trouble ZONE 12.MD/COM 351
    LINE FAIL+ Mod Tel line fail trouble MOD 12.MD/COM 351
    LX Local Prog end ENGINEER- Engineer mode exited EVENT ALWAYS TR 627
    Event Codes (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    B-7
    M - Medical (Custom SIA - See note 2)
    MA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
    MB Bypass OMITTEDzone ommitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    MJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
    MR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
    18.ZN RESTO
    MT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    MU UnbypassFORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
    O - Opening
    OA Open Report UNSET Automatic Unset EVENT 10.SETTING 401
    OG Open Area UNSET Part Unset USER 10.SETTING 401
    KSW UNSET Keyswitch part unset ZONE 10.SETTING 409
    OK Early Open U/S EARLYUnset Early EVENT 10.SETTING 451
    OP Open Report UNSET Unset USER 10.SETTING 401
    KSW UNSET Keyswitch  unsetZONE 10.SETTING 409
    OR Disarm alarm SYS RESET All Burglar alarms resetUSER 11.RESET 313
    PA RESET All PA alarms reset USER  1.PA/DURE 465
    TAMP RST All Tamper alarms reset USER9.TAMPER 313
    SYS RESET Ksw reset Burglar alarm EVENT 11.RESET 313
    PA RESET Ksw reset PA alarms EVENT 1.PA/DURE 465
    TAMP RESET Ksw reset Tamp alarm EVENT9.TAMPER 313
    LF RESET USER 20.FAULT 313
    FAULT RST USER 20.FAULT 313
    PF RESET USER 20.FAULT 313
    Event Codes (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    B-8
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    P - Panic
    PA Panic Alarm PA+ PA zone alarm ZONE 1.PA/DURE 120
    DELAY ALM+ PA Delay zone alarm ZONE 1.PA/DURE 120
    PB Panic Bypass  OMITTED PA zone omitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    PJ  Pan Troub rest LOW RES- Restor zone  resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone  resistance ZONE 15.TROUBL 380
    PR Panic Restoral PA- PA zone restored ZONE1.PA/DURE 120
    18.ZN RESTO
    DELAY ALM- PA Delay zone restored ZONE 1.PA/DURE 120
    18.ZN RESTO
    PT Panic Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    PU Panic Unbypas FORCE OMT- Unomitted after rearm ZONE8.OMIT 573
    Q - Assist (Custom SIA - see note 2)
    QA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
    QB Bypass OMITTEDzone ommitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    QJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
    QR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
    18.ZN RESTO
    QT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    QU Unbypass FORCE OMT- Unomitted after rearmZONE 8.OMIT 573
    R - Remote,Log,Test
    RB REM LOG USER NONE 0
    REM RESET USER NONE 0
    REM ID USER NONE 0
    REM COPY USER NONE 0
    REM OVRWR USER NONE 0
    REM MSG USER NONE 0
    COPY SITE MODULE NONE 0
    OVWR SITE MODULE NONE 0
    RC Relay closed LINK-Link zone closed ZONE 16.LOG 150
    LOG-Log zone closed ZONE 16.LOG 150
    LOG DELAY-Log delay zone closed ZONE 16.LOG 150
    CUSTOM A-Zone closed(Non alarm) ZONE 16.LOG 150
    CUSTOM B- Zone closed(Non alarm) ZONE 16.LOG 150
    EXITGUARD- Exitguard zone closed ZONE 16.LOG 150
    Event Codes (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    B-9
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    RD Prog, denied RMACCESS+Zone denied rem. acc ZONE 14.MEN AC 553
    RO Relay open BELL FAIL Bell fail zone opened ZONE 16. LOG 150
    KEYSWITCH KS NONE 150
    LINK+ Link zone opened ZONE 16.LOG 150
    LOG+ Log zone opened ZONE 16.LOG 150
    LOG DELAY+ Log delay zone opened ZONE 16.LOG 150
    NOT USED ZONE 16. LOG 150
    SET LOG ZONE 16. LOG 150
    CUSTOM A+ Zone opend(Non alarm) ZONE 16.LOG 150
    CUSTOM B+ Zone opend(Non alarm) ZONE 16.LOG 150
    EXITGUARD+Exitguard zone opened ZONE 16.LOG 150
    PUSH SET Push set zone opened ZONE NONE 150
    KSW RESET KS NONE 150
    SPARESpare zone opened ZONE 16. LOG 150
    RP Automatic test AUTOTEST Automatic test EVENT ALWAYS TR 602
    RR Power Up MEMORY OK Warm start of panel EVENT 13.ELEC ST 305
    RS Prog,  success RM ACCESS- Zone allowed rem acc ZONE 14.MEN AC 553
    REM CALL Remote call complete MOD 14.MEN AC 412
    RX Manual test ENG TEST Engineer test USER ALWAYS TR 601
    S - Sprinker (Custom SIA - see note 2)
    SA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
    SB Bypass OMITTEDzone ommitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    SJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
    SR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
    ST Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    SU Unbypass FORCE OMT-Unomitted after rearmZONE 8.OMIT 573
    T - Tamper,Test
    TA Tamper AlarmTAMPER+ Tamper zone alarm ZONE9.TAMPER 137
    BELL TAMP+ Bell Tamper zone alarm ZONE9.TAMPER 137
    LID TAMP+ Lid Tamper alarm ZONE9.TAMPER 137
    AUX TAMP+ Auxilary Tamper alarm ZONE9.TAMPER 137
    TAMP S/C+ Tamper short circuit ZONE9.TAMPER 383
    TAMP O/C+ Tamper open circuit ZONE9.TAMPER 383
    TAMPER+ Module Tamper MOD9.TAMPER 145
    MISSING+Missing module alarmMOD 9.TAMPER 145
    CV TAMP+ Voltage tamper on zone ZONE9.TAMPER 383
    MAX TAMP+ MAX Module Tamper MOD.9.TAMPER 145
    WALL TAMP Wall tamper zone alarm ZONE9.TAMPER 137
    MASK TAMP ZONE9.TAMPER 383
    ADDED Module AddedMOD. 9.TAMPER 531
    ENG TAMP+ Engineering TamperMISC 9.TAMPERNone
    TE Test End WALK TEST- Walk test finished USER 14.MEN AC 607
    Event Codes (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    B-10
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    TR Tamper Restor TAMPER- Tamper zone restored ZONE9.TAMPER 137
    18.ZN RESTO
    BELL TAMP- Bell Tamper zone rest. ZONE9.TAMPER 137
    18.ZN RESTO
    LID TAMP- Lid Tamper restored ZONE9.TAMPER 137
    18.ZN RESTO
    AUX TAMP- Auxilary Tamper rest. ZONE9.TAMPER 137
    18.ZN RESTO
    TAMP S/C- Tamper s/circuit rest. ZONE9.TAMPER 383
    18.ZN RESTO
    TAMP O/C- Tamper o/circuit rest. ZONE9.TAMPER 383
    18.ZN RESTO
    TAMPER- Module Tamper rest. MOD9.TAMPER 145
    18.ZN RESTO
    MISSING-Missing module rest.MOD 9.TAMPER 145
    18.ZN RESTO
    CV TAMP- Voltage tamper rest. ZONE9.TAMPER 383
    18.ZN RESTO
    MAX TAMP- MAX Module Tamp rest MOD.9.TAMPER 145
    18.ZN RESTO
    ENG TAMP- Engineer TamperMISC 9.TAMPERNone
    18.ZN RESTO
    TS Test Start WALK TEST+ Walk test started USER 14.MEN AC 607
    ARC TEST TEST ALWAYS TR 607
    V -??
    VY PRINT OC USER NONE 0
    PRINT OL MISC NONE 0
    W - Water(Custom SIA - see note 2)
    WA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
    WB Bypass OMITTEDzone ommitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    WJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
    WR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
    18.ZN RESTO
    WT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    WU Unbypass FORCE OMT- Unomitted after rearmZONE 8.OMIT 573
    Event Codes (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    B-11
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    X - RF
    XQ RF Jam RF JAM+ RF Signal Jammed MOD 15.TROUBLE 344
    XT RF Batt Low RF BATLOW+ RF Battery Low ZONE 13.ELEC ST 384
    15.TROUBLE
    XH RF Jam Restore RF JAM- RF Jam Restore MOD 15.TROUBLE 344
    XR RF Batt Lo Rst RF BATLOW- RF Battery Low Restore ZONE 13.ELEC ST 384
    15.TROUBLE
    Y
    YC Comms Fail internal to tel Tel module lost RS485 EVENT ALWAYS TR 350
    YF Panel Cold Start MEM RESET Power Up PanelMISC 13.ELEC ST None
    Y K Comm Restoralinternal to tel Tel module rest. RS485EVENT A LWAY S  T R 3 5 0
    Y L +AC+ Batt Fail+AC+BATT Mains fail and batt lowEVENT13.ELEC STNone
    YP PSU failPSU FLT+Power Supply Unit faultEVENT13.ELEC ST 314
    YR Sys Batt Rest.BATT LOW- Battery Low restoredZONE13.ELEC ST 302
    CU BATT- Control unit batt restoreZONE13.ELEC ST 302
    BATT LOW- Mod Battery Low rest MOD 13.ELEC ST 302
    BATT FUSE- Battery Fuse restored MOD 13.ELEC ST 302
    YT Sys Batt Troub BATT LOW+ Battery Low ZONE 13.ELEC ST 302
    CU BATT+ Control unit Battery Low ZONE 13.ELEC ST 302
    BATT LOW+ Module Battery Low MOD 13.ELEC ST 302
    BATT FUSE+ Battery Fuse blown MOD 13.ELEC ST 302
    FUSE A2P MOD 13.ELEC ST 302
    Z - Freezer (Custom SIA - see note 2)
    ZA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
    ZB Bypass OMITTEDzone ommitted ZONE8.OMIT 573
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    ZJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
    ZR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
    18.ZN RESTO
    ZT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
    HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
    ZU Unbypass FORCE OMT- Unomitted after rearmZONE 8.OMIT 573
    00 - Non-reported Events
    00 SUSP. SET USER NONE 0
    00 BEGIN SET USER NONE 0
    00 INST SET USER NONE 0
    00 ENT UNSET UNSET NONE 0
    00 ENT SETTING USER NONE 0
    00 ENT DELAY USER NONE 0
    00 ENT SET USER NONE 0
    00 ENT UNSTG USER NONE 0
    00 ABORT SET USER NONE 0
    00 AUDIBLE MISC NONE 0
    00 JAM DELAY MISC NONE 0
    00 FB BATLOWUSER NONE 0
    Event Codes (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    B-12
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event Description Trigger ID Event
    00 DIAG REC LIST NONE 0
    00 LOC WRITE LIST NONE 0
    00 REM WR/RD LIST NONE 0
    00 DIAG CHK LIST NONE 0
    00 DISCHARGE ZONE 13.ELEC ST 0
    00 ETST PASS USER NONE 0
    00 ETST FAIL MISC NONE 0
    00 OVERRIDE MISC NONE 0
    00 R. TIMESET MISC NONE 0
    00 CU-RIO.SW MISC NONE 0
    00 CLBK1 ERR USER NONE 0
    00 REM TRY USER NONE 0
    00 REM FIN USER NONE 0
    00 REM ABORT USER NONE 0
    00 REM FAIL USER NONE 0
    Note 1 : Dependant upon zone type selected
    Note 2: Custom SIA event allow existing zone types to be modified in order to send specific SIA events from the panel. This allows more
    specific SIA information to be transmitted. The zones used to programme the custom SIA events will continue to function as per the zone
    description
    Event Codes (cont’d) 
    						