Galaxy 3 Series Programming Manual 175 Option 68 – Menu Access The Menu Access option is used to assign access types to each of the menu options. This allows code types 2.3 – 3.6 to have access to menu options to which they would normally have insufficient access rights. On selecting this option, 11 = OMIT ZONES is displayed along with the current code types assigned (3456 default). Use the A or B key to select the required menu option or enter the option number directly and press the ent key. The currently assigned types appear displayed on the top line of the display. The type maps default to the standard access. To modify the types, press the required number keys; this toggles the access type numbers on the bottom line of the display on and off. Press the ent key to save the programming and return to the previous menu level. If the level is assigned to the option the number is displayed, if it has been removed a dash (–) is displayed. For example, type 2.5 5 codes can be given access to menu 42 which would allow them to allocate codes. Users can only allocate codes up to the type that they have been assigned. A type 2.4 user cannot assign a user code as type 2.5. NOTE:The following menu access types are fixed: option 48 = DATELOCK level 3.6, and option 68 = MENU ACCESS engineer access (type 3.7 and 3.8). Levels LevelsLevels Levels Levels ––-6 ––-6––-6 ––-6 ––-6 42=CODES 42=CODES42=CODES 42=CODES 42=CODES 68 - Menu Access Levels 3456 Levels 3456Levels 3456 Levels 3456 Levels 3456 11=OMIT ZONES 11=OMIT ZONES11=OMIT ZONES 11=OMIT ZONES 11=OMIT ZONES Levels 3456 Levels 3456Levels 3456 Levels 3456 Levels 3456 >–-5- >–-5- >–-5- >–-5- >–-5-
Galaxy 3 Series Programming Manual 176 71 - SPI Key Section 10: Engineer 3 Option 71 - SPI Key The SPI (Serial Peripheral Interface) key is an engineering peripheral used for copy/overwriting programming data and carrying out software upgrades. Fitting the SPI Key The SPI key is fitted directly on to the Galaxy 3 Series control panel. CAUTION:Always power down the panel BEFORE removing or connecting the SPI key. Failure to do so may result in damage to the SPI key. Never “hot-plug” the SPI key. The SPI Key has a 10-way connector. These locate on to the 10 pins of the SPI Program Header (see Figures 14 and 15). NOTE:The SPI Key should only be fitted in the direction shown in Figure 14. Figure 14. Location of SPI Key on Program HeaderFigure 15. SPI Key 1. Release the hinged cap to expose the 10-way connector. 2. Plug the SPI Key on to the Program Header on the Galaxy 3 Series control panel. SPI KeyControl Panel (part view) SPI Program Header Fitted here 10-way connector Hinged cap
Galaxy 3 Series Programming Manual 177 71 - SPI Key (cont’d) Using the SPI Key If no key is fitted the display will briefly show: SPI Keys can be supplied in one of two ways: 1. Programmed - the SPI Key will be pre-programmed with a specific application file. 2. Un-programmed - The SPI Key is blank and contains no application or configuration data. If the SPI Key is fitted and the key is blank, then the only option presented to the user will be 1 = Format Key. 1 = Format Key This function formats the key ready for copy and overwriting of panel configuration data. On selecting this option the user is presented with a display where the top line reads “Formatting”, with a progress bar shown on the bottom line. Once the key has been formatted the user is presented with the following options: 1 = Show Key This option is only shown when there is existing information stored on the SPI Key and then provides options for downloading the saved information into the panel. The user can scroll through the available files on the SPI Key. For each file the display toggles between the: Filename, creation time and date of the saved data and the, Panel Type, Panel version and file type. A further press of the ent key will provide the user with the following two options: 1 = Use File Selecting this option will reprogram your control panel with the software stored on the SPI key. This will take approximately 2 minutes. NOTE:If a new panel application file is being downloaded, the panel configuration stored in the panel should firstly be saved from the panel to the SPI Key. The new panel application can then copied from the SPI Key to the panel. Once the new application has been downloaded the saved panel configuration can be copied back to the panel. Once the process has started, the panel will validate the data, then begin reprogramming the control panel. While reprogramming is taking place, the panel stops running. The keypads and other peripherals will go off-line for a short period. Once the reprogramming is complete, the panel will automatically reboot. Once the panel has fully reconfigured, power may be removed or any previously saved configuration can be restored via option 1 = show key and selecting the appropriate file. CAUTION:Do not remove power or unplug the SPI key until the panel has restarted. SPI Key: SPI Key:SPI Key: SPI Key: SPI Key: Device error Device errorDevice error Device error Device error
Galaxy 3 Series Programming Manual 178 71 - SPI Key (cont’d) 2 = Delete File When selected, the binary file stored on the SPI Key is deleted. CAUTION:Do not use this command as the SPI key will have to be recalled to Honeywell Security to be reprogrammed with the software. 2 = Save config This option allows the panel configuration data to be saved to SPI Key. If selected the user is first prompted for filename for the saved data. This can be up to 8 characters in length. Once the filename has been entered the data save sequence is started. The keypad display gives an indication of the progress until the configuration has been saved. 3 = Check space If selected this option displays the available space left on the SPI Key. This will display the number of free memory Kbytes left on the device, out of a maximum of 4096. 4 = Erase key This option deletes all programming and returns the SPI key to the unformatted state. This option should not be used. NOTE:If replacing the software all users, other than the engineer at the keypad in use will be logged out of the system. The keypad banner will display a warning of what is happening. The engineer will be given a warning that the panel software is about to be replaced. It will take approximately 2 minutes to replace the software, during which time the keypads will go off line. Once reprogrammed the panel will restart. Removing the SPI Key CAUTION:Always power down the panel BEFORE removing or connecting the SPI key. Failure to do so may result in damage to the SPI key. Never “hot-plug” the SPI key. 1. Remove the SPI Key from the Program Header on the Galaxy 3 Series control panel. 2. Secure the hinged cap to protect the 10-way connector.
Galaxy 3 Series Programming Manual A-1 00 0 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 space 11 Å 12 Ä 13 A 14 Æ 15 B 16 C 17 D 18 E 19 F 20 G 21 space 22 H 23 I 24 J 25 K 26 L 27 M 28 N 29 Ø 30 Ö 31 O 32 space 33 P 34 Q 35 R 36 S 37 T 38 U 39 Ü 40 V 41 W 42 X 43 space 44 Y 45 Z 46 . 47 , 48 / 49 - 50 + 51 & 52 ( 53 ) 54 space001 ABOVE 002 ACCESS 003 ACCOUNTANT 004 ACCOUNTANTS 005 ACCOUNTS 006 ADMIN. 007 ALARM 008 ALERT 009 ANIMAL 010 ANNEXE 011 ARCH 012 AREA 013 ARENA 014 AROUND 015 ART 016 ASSEMBLY 017 ASSISTANT 018 AT 019 ATTACK 020 ATTIC 021 AUTOMATIC 022 AUXILIARY 023 BACK 024 BAGGAGE 025 BAKERY 026 BALCONY 027 BALLROOM 028 BANK 029 BANKING 030 BAR 031 BARN 032 BASEMENT 033 BATH 034 BATHROOM 035 BAY 036 BEAM 037 BEDROOM 038 BEHIND 039 BELL 040 BELOW 041 BENCH 042 BESIDE 043 BIOLOGY 044 BIRD 045 BLOCK 046 BLUE 047 BOARD 048 BODY 049 BOILER 050 BOOTH 051 BOTTOM 052 BOX 053 BOYS 054 BRANCH 055 BROOM 056 BROWN 057 BUILDING 058 BUNKER059 B Y 060 CABINET 061 CAFE 062 CALL 063 CANTEEN 064 CAR 065 CARGO 066 CARPENTER 067 CARPET 068 CASH 069 CASHIER 070 CEILING 071 CELL 072 CELLAR 073 CENTRAL 074 CENTRE 075 CHAIR 076 CHANGING 077 CHEMISTRY 078 CHICKEN 079 CHURCH 080 CLASSROOM 081 CLEANER 082 CLEANERS 083 CLEANING 084 CLERK 085 CLERKS 086 COAL 087 COAT 088 COIN 089 COLD 090 COLLECTION 091 COMMUNICATOR 092 COMPUTER 093 CONFERENCE 094 CONTAINER 095 CONTACT 096 CONSERVATORY 097 CORNER 098 CORRIDOR 099 COUNTER 100 COURT 101 COW 102 CUPBOARD 103 CURRENCY 104 DAIRY 105 DARK-ROOM 106 DATA 107 DAY 108 DEPARTURE 109 DEPUTY 110 DEPT. 111 DESIGN 112 DESK 113 DETECTOR 114 DEVELOPMENT 115 DEVICE 116 DIARY117 DINING 118 DIRECTOR 119 DIRECTORS 120 DISPATCH 121 DOG 122 DOOR 123 DOUBLE 124 DOWNSTAIRS 125 DRAMA 126 DRAWER 127 DRAWING 128 DRINKS 129 DRIVE 130 DRUGS 131 EAST 132 ECONOMICS 133 EDGE 134 EIGHT 135 EIGHTEEN 136 EIGHTY 137 ELECTRIC 138 ELECTRICIAN 139 ELECTRONICS 140 EMERGENCY 141 END 142 ENGINE 143 ENGINEER 144 ENGINEERS 145 ENGLISH 146 ENTRANCE 147 ENTRY 148 EQUIPMENT 149 ESCAPE 150 ESCALATOR 151 EXIT 152 EXPORT 153 EXTERNAL 154 FACTORY 155 FAILURE 156 FAR 157 FARM 158 FAX 159 FEED 160 FEMALE 161 FENCE 162 FIELD 163 FIFTEEN 164 FIFTY 165 FLING 166 FIRE 167 FIRST 168 FIRST-AID 169 FISH 170 FIVE 171 FLAT 172 FLOOR 173 FOR Appendix A: Library Library
Galaxy 3 Series Programming Manual A-2 174 FOREIGN 175 FORTY 176 FOUNTAIN 177 FOUR 178 FREEZER 179 FRENCH 180 FRIDGE 181 FROM 182 FRONT 183 GAMES 184 GARAGE 185 GARDEN 186 GATE 187 GENTS 188 GEOGRAPHY 189 GERMAN 190 GIRLS 191 GLASS 192 GOLD 193 GOODS 194 GREAT 195 GREEN 196 GROCERY 197 GROUND 198 GROUNDS 199 GROUNDSMAN 200 GROUP 201 GUARD 202 GUN 203 GYM 204 HALL 205 HAND 206 HANGER 207 HEAD 208 HEAT 209 HEATER 210 HIGH 211 HISTORY 212 HOME 213 HORSE 214 HOT 215 HOUSE 216 ICE 217 IN 218 INDUSTRIAL 219 INFANT 220 INFANTS 221 INFORMATION 222 INFRARED 223 INSIDE 224 INSTRUCTORS 225 INTERIOR 226 INTO 227 IRON 228 ISOLATION 229 IT 230 ITALIAN 231 JANITOR 232 JANITORS 233 JUDGE 234 JUNIOR235 JUST 236 KEEP 237 KEYPAD 238 KITCHEN 239 LAB 240 LADIES 241 LANDING 242 LAST 243 LATIN 244 LAUNDRY 245 LAVATORY 246 LAWN 247 LEAST 248 LECTURE 249 LEFT 250 LEVEL 251 L.H.S. 252 LIBRARY 253 LIFT 254 LIGHT 255 LINE 256 LITTLE 257 LOADING 258 LOBBY 259 LOCK 260 LOFT 261 LORRY 262 LOUNGE 263 LOW 264 LUNCH 265 MACHINE 266 MAGNETIC 267 MAIN 268 MAJOR 269 MALE 270 MAN 271 MANAGER 272 MANAGERS 273 MASTER 274 MAT 275 MATHS 276 MEDICAL 277 MEN 278 MESS 279 METAL 280 METER 281 MEZZANINE 282 MICROWAVE 283 MIDDLE 284 MILK 285 MINOR 286 MOBILE 287 MODEL 288 MONITOR 289 MOULDING 290 MOVEMENT 291 NEAR 292 NEW 293 NEXT 294 NIGHT 295 NINE296 NINETEEN 297 NINETY 298 NODE 299 NOISE 300 NURSE 301 NURSERY 302 NORTH 303 OF 304 OFFICE 305 OFFICER 306 OFFICERS 307 OFFICES 308 OIL 309 ON 310 ONE 311 OPEN 312 ORANGE 313 OUT 314 OUTER 315 OUTSIDE 316 OVAL 317 OVER 318 P.A. BUTTON 319 PACKING 320 PAINT 321 PANEL 322 PANIC 323 PANTRY 324 PARCEL 325 PARK 326 PARTITION 327 PASSIVE 328 PATH 329 PATIO 330 PEN 331 PENTHOUSE 332 PERIMETER 333 PERSONAL 334 PERSONNEL 335 PHONE 336 PHYSICS 337 PIG 338 PIR 339 PIR BY 340 PIR IN 341 PIR ON 342 PLACE 343 PLANT 344 PLAY 345 PLAZA 346 PLUMBER 347 PLUMBERS 348 POINT 349 POND 350 POOL 351 PORCH 352 POST 353 POWER 354 PRESSURE 355 PRIMARY 356 PRIME Library (cont’d)
Galaxy 3 Series Programming Manual A-3 357 PRINT 358 PROCESSING 359 PRODUCTION 360 PUBLIC 361 PURCHASING 362 PURPLE 363 QUALITY 364 QUANTITY 365 QUIET 366 QUICK 367 RANGE 368 READING 369 REAR 370 RECEPTION 371 RECORDS 372 RECTOR 373 RECTORS 374 RED 375 REED 376 REFECTORY 377 REMOTE 378 REPAIR 379 RESEARCH 380 REST 381 RESTAURANT 382 REVOLVING 383 RIGHT 384 R.H.S. 385 ROLLER 386 ROOF 387 ROOM 388 ROUND 389 RUN 390 SAFE 391 SALES 392 SCAN 393 SCANNER 394 SCANNERS 395 SCANNING 396 SCREEN 397 SEA 398 SECOND 399 SECURE 400 SECRETARIES 401 SECRETARY 402 SECTION 403 SECURITY 404 SENSOR 405 SEVEN 406 SEVENTEEN 407 SEVENTY 408 SHACK 409 SHAFT 410 SHED 411 SHEEP 412 SHOP 413 SHOWROOM 414 SHORT 415 SHOWER 416 SHUTTER 417 SIDE418 SILENT 419 SILVER 420 SITE 421 SITTING 422 SIX 423 SIXTEEN 424 SIXTY 425 SLIDING 426 SMOKE 427 SOFTWARE 428 SOLITARY 429 SOUND 430 SOUTH 431 SPANISH 432 SPRAY 433 SPRING 434 SQUARE 435 SQUASH 436 STABLE 437 STADIUM 438 STAFF 439 STAIRS 440 STAIRWELL 441 STALLS 442 STAND 443 START 444 STATION 445 STOP 446 STORE 447 STORES 448 STROBE 449 STRONG 450 STUDY 451 SUITE 452 SUMMER 453 SUNDAY 454 SUPPLY 455 SURGERY 456 SWIMMING 457 SWITCH 458 SYSTEM 459 TABLE 460 TALL 461 TAMPER 462 TEA 463 TEACHER 464 TECHNICAL 465 TECHNICIAN 466 TELLER 467 TEN 468 TENNIS 469 TEST 470 THE 471 THEATRE 472 THEN 473 THIRTEEN 474 THIRTY 475 THREE 476 TICKET 477 TILL 478 TO479 TOILET 480 TOOL 481 TOP 482 TRACK 483 TRACTOR 484 TRADE 485 TRAILER 486 TRAIN 487 TRAINING 488 TRANSPORT 489 TRAP 490 T.V. 491 TWELVE 492 TWENTY 493 TWIN 494 TWO 495 TYPE 496 TYPING 497 TYRE 498 ULTRASONIC 499 UNDER 500 UNIT 501 UP 502 UPPER 503 UPSTAIRS 504 USER 505 UTILITY 506 VAN 507 VARIABLE 508 VAULT 509 VENTILATOR 510 VISUAL 511 VOLTAGE 512 WAITING 513 WALK 514 WALL 515 WARD 516 WAREHOUSE 517 WASH 518 WATER 519 WAY 520 W.C. 521 WEAPON 522 WEEKEND 523 WEST 524 WINDOW 525 WINTER 526 WITH 527 WOOD 528 WOODWORK 529 WORK 530 WORKS 531 WORKSHOP 532 X-RAY 533 YARD 534 YEAR 535 YELLOW 536 ZERO 537 ZONE 538 ZOO Library (cont’d)
Galaxy 3 Series Programming Manual B-1 Appendix B: SIA and Contact ID Event Codes Event Codes Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact Description Event DescriptionTrigger ID Event A - Alarm Cause AC Alarm CauseALM CAUSEUser report alarm causeUSER A LWAY S T RNone A - AC Power AR AC Restoral AC FAIL- AC Fail zone restoredZONE 13.ELEC.ST 301 CU-AC- Control Unit AC restred ZONE13.ELEC.ST 301 AC FAIL- Module AC fail restored MOD.13.ELEC.ST 301 STAND LOW- Standby Battery Low MOD13.ELEC.ST 301 CU FUSE- Control Unit fuse rest. MISC 9.TAMPER 300 13. ELEC.ST AT AC Trouble AC FAIL+ AC Fail zone troubleZONE 13.ELEC.ST 301 CU-AC+ Control Unit AC trouble ZONE13.ELEC.ST 301 AC FAIL+ Module AC fail trouble MOD.13.ELEC.ST 301 STAND LOW+ Standby Battery Low MOD 13.ELEC ST 301 CU FUSE+ Control Unit fuse trouble MISC 9. TAMPER 300 13.ELEC ST FUSE AUX1 Aux1 fuse trouble MOD9.TAMPER 300 13.ELEC ST FUSE AUX2 Aux2 fuse trouble MOD9.TAMPER 300 13.ELEC ST FUSE BELL Bell fuse trouble MOD9.TAMPER 300 13.ELEC ST B - Burglary BA Burglary Alarm ENTRY Entry zone alarm ZONE NONE 150 EXIT+ Exit zone alarm ZONE 2.INTRUDE 134 INTRUDER+ Intruder zone alarm ZONE 2.INTRUDE 130 24 HOURS+ 24 hour zone alarm ZONE 3.24 HOURS 135 SECURITY+ Security zone alarm ZONE4.SECURITY 135 DUAL+ Dual zone alarm ZONE 2.INTRUDE 130 FINAL Final zone alarm ZONE NONE 150 SEC FINAL+ Secure final zone alarm ZONE 4.SECURITY 134 PRT FINAL+ Part final zone alarm ZONE 2.INTRUDE 134 PRT ENTRY+ Part entry zone alarm ZONE 2.INTRUDE 134 BEAM PAIR+ Beam pair zone alarm ZONE 2.INTRUDE 130 VIDEO+ Video zone alarm ZONE 2.INTRUDE 130 VIDEO EXT+ Video exit zone alarm ZONE 2.INTRUDE 130 CUSTOM A+ Custom A zone alarm ZONE 5.CUS ZON 130 CUSTOM B+ Custom B zone alarm ZONE 5.CUS ZON 130 MASK+Mask zone alarmZONE 4.SECURITY 135 INT DELAY Intruder Delay alarm ZONE 2.INTRUDE 150 URGENT+ Urgent zone alarm ZONE 3.24 HOURS 130 VIBRATION+Vibration zone alarm ZONE 2.INTRUDE 133 ATM-1+ ATM-1 zone alarm ZONE 3.24 HOURS 133 ATM-2+ ATM-2 zone alarm ZONE 3.24 HOURS 133 ATM-3+ ATM-3 zone alarm ZONE 3.24 HOURS 133 ATM-4+ ATM-4 zone alarm ZONE 3.24 HOURS 133 ALARM EXT+ Extend zone alarm ZONE 3.24 HOURS 130 T/O BURGL+ Entry timeout with zone ZONE 2.INTRUDE 134
Galaxy 3 Series Programming Manual B-2 Event Codes (cont’d) Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact Description Event DescriptionTrigger ID Event BB Burg BypassOMITTEDZone omittedZONE 8.OMIT 5 7 3 FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573 GRP OMIT+ Group omitted USER 8.OMIT 574 OMIT VIBS Omit Vibration zone EVENT 8.OMIT 572 OMIT-ATM1+ Omit ATM-1 zone EVENT8.OMIT 572 OMIT-ATM2+ Omit ATM-2 zone EVENT8.OMIT 572 OMIT-ATM3+ Omit ATM-3 zone EVENT8.OMIT 572 OMIT-ATM4+ Omit ATM-4 zone EVENT8.OMIT 572 BC Burg Cancel KSW CANCLKeyswitch Cancel ZONE11.RESET 406 CANCELCancel by userUSER 11.RESET 4 0 6 BF Intruder HighINTR HIGHIntruder zone alarmZONE 2. INTRUDE 1 3 0 BJ Burg Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380 HIGH RES- Restor zone resistance ZONE 15.TROUBL 380 RF SUPER- RF Supervision FailureZONE15.TROUBL 381 BL Intruder LowINTR LOWIntruder zone alarmZONE 2. INTRUDE 1 3 0 BR Burglary RestEXIT-Exit zone type restoredZONE2.INTRUDE 1 3 4 18.ZN RESTO INTRUDER- Intruder zone restored ZONE 2.INTRUDE 130 18.ZN RESTO 24 HOURS- 24 hour zone restored ZONE 3.24 HOURS 135 18.ZN RESTO SECURITY- Security zone restored ZONE 4.SECURITY 135 18.ZN RESTO DUAL- Dual zone restored ZONE 2.INTRUDE 130 18.ZN RESTO SEC FINAL- Secure final zone rest. ZONE 4.SECURITY 134 18.ZN RESTO PRT FINAL- Part final zone restored ZONE 2.INTRUDE 134 18.ZN RESTO PRT ENTRY- Part entry zone restored ZONE 2.INTRUDE 134 18.ZN RESTO BEAM PAIR- Beam pair zone rest. ZONE 2.INTRUDE 130 18.ZN RESTO VIDEO- Video zone restored ZONE 2.INTRUDE 130 18.ZN RESTO VIDEO EXT- Video exit zone rest. ZONE 2.INTRUDE 130 18.ZN RESTO CUSTOM A- Custom A zone rest. ZONE 5.CUS ZON 130 18.ZN RESTO CUSTOM B- Custom B zone rest. ZONE 5.CUS ZON 130 18.ZN RESTO MASK- Mask zone restored ZONE4.SECURITY 135 18.ZN RESTO INT ALARM- Intruder Delay restored ZONE 2.INTRUDE 130 18.ZN RESTO URGENT- Urgent zone restored ZONE 3.24 HOURS 130 18.ZN RESTO VIBRATION- Vibration zone restored ZONE 2.INTRUDE 133 18.ZN RESTO