Home > Honeywell > Control panel > Honeywell Galaxy 3 User Manual

Honeywell Galaxy 3 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell Galaxy 3 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Galaxy 3 Series Programming Manual
    175
    Option 68 – Menu Access
    The Menu Access option is used to assign access types to each of the menu options. This allows code types
    2.3 – 3.6 to have access to menu options to which they would normally have insufficient access rights.
    On selecting this option, 11 = OMIT ZONES is displayed along with the current code types assigned (3456
    default).
    Use the A or B key to select the required menu option or enter the option number directly and press the ent
    key. The currently assigned types appear displayed on the top line of the display. The type maps default to the
    standard access. To modify the types, press the required number keys; this toggles the access type numbers
    on the bottom line of the display on and off.
    Press the ent key to save the programming and return to the previous menu level. If the level is assigned to the
    option the number is displayed, if it has been removed a dash (–) is displayed.
    For example, type 2.5 5 codes can be given access to menu 42 which would allow them to allocate codes.
    Users can only allocate codes up to the type that they have been assigned.  A type 2.4 user cannot assign a
    user code as type 2.5.
    NOTE:The following menu access types are fixed: option 48 = DATELOCK level 3.6, and option 68 =
    MENU ACCESS engineer access (type 3.7 and 3.8).
    Levels LevelsLevels Levels
    Levels
    ––-6 ––-6––-6 ––-6
    ––-6
    42=CODES 42=CODES42=CODES 42=CODES
    42=CODES
    68 - Menu Access
    Levels     3456 Levels     3456Levels     3456 Levels     3456
    Levels     3456
    11=OMIT ZONES 11=OMIT ZONES11=OMIT ZONES 11=OMIT ZONES
    11=OMIT ZONES
    Levels    3456 Levels    3456Levels    3456 Levels    3456
    Levels    3456
          >–-5-       >–-5-      >–-5-       >–-5-
          >–-5- 
    						
    							Galaxy 3 Series Programming Manual
    176
    71 - SPI Key
    Section 10:  Engineer 3
    Option 71 - SPI Key
    The SPI (Serial Peripheral Interface) key is an engineering peripheral used for copy/overwriting programming
    data and carrying out software upgrades.
    Fitting the SPI Key
    The SPI key is fitted directly on to the Galaxy 3 Series control panel.
    CAUTION:Always power down the panel BEFORE removing or connecting the SPI key.
    Failure to do so may result in damage to the SPI key. Never “hot-plug” the SPI
    key.
    The SPI Key has a 10-way connector. These locate on to the 10 pins of the SPI Program Header
    (see Figures 14 and 15).
    NOTE:The SPI Key should only be fitted in the direction shown in Figure 14.
    Figure 14. Location of SPI Key on Program HeaderFigure 15. SPI Key
    1. Release the hinged cap to expose the 10-way connector.
    2. Plug the SPI Key on to the Program Header on the Galaxy 3 Series control panel.
    SPI KeyControl
    Panel
    (part view)
    SPI
    Program
    Header
    Fitted
    here
    10-way
    connector
    Hinged
    cap 
    						
    							Galaxy 3 Series Programming Manual
    177
    71 - SPI Key (cont’d)
    Using the SPI Key
    If no key is fitted the display will briefly show:
    SPI Keys can be supplied in one of two ways:
    1. Programmed - the SPI Key will be pre-programmed with a specific application file.
    2. Un-programmed - The SPI Key is blank and contains no application or configuration data.
    If the SPI Key is fitted and the key is blank, then the only option presented to the user will be 1 = Format
    Key.
    1 = Format Key
    This function formats the key ready for copy and overwriting of panel configuration data. On selecting this
    option the user is presented with a display where the top line reads “Formatting”, with a progress bar shown
    on the bottom line.
    Once the key has been formatted the user is presented with the following options:
    1 = Show Key
    This option is only shown when there is existing information stored on the SPI Key and then provides options
    for downloading the saved information into the panel. The user can scroll through the available files on the SPI
    Key.
    For each file the display toggles between the:
    Filename, creation time and date of the saved data and the,
    Panel Type, Panel version and file type.
    A further press of the ent key will provide the user with the following two options:
    1 = Use File
    Selecting this option will reprogram your control panel with the software stored on the SPI key.
    This will take approximately 2 minutes.
    NOTE:If a new panel application file is being downloaded, the panel configuration stored in the
    panel should firstly be saved from the panel to the SPI Key. The new panel application can
    then copied from the SPI Key to the panel. Once the new application has been
    downloaded the saved panel configuration can be copied back to the panel.
    Once the process has started, the panel will validate the data, then begin reprogramming the control
    panel. While reprogramming is taking place, the panel stops running. The keypads and other peripherals
    will go off-line for a short period. Once the reprogramming is complete, the panel will automatically
    reboot. Once the panel has fully reconfigured, power may be removed or any previously saved
    configuration can be restored via option 1 = show key and selecting the appropriate file.
    CAUTION:Do not remove power or unplug the SPI key until the panel has restarted.
    SPI Key: SPI Key:SPI Key: SPI Key:
    SPI Key:
    Device error Device errorDevice error Device error
    Device error 
    						
    							Galaxy 3 Series Programming Manual
    178
    71 - SPI Key (cont’d)
    2 = Delete File
    When selected, the binary file stored on the SPI Key is deleted.
    CAUTION:Do not use this command as the SPI key will have to be recalled to Honeywell
    Security to be reprogrammed with the software.
    2 = Save config
    This option allows the panel configuration data to be saved to SPI Key. If selected the user is first prompted
    for filename for the saved data. This can be up to 8 characters in length.
    Once the filename has been entered the data save sequence is started. The keypad display gives an indication
    of the progress until the configuration has been saved.
    3 = Check space
    If selected this option displays the available space left on the SPI Key. This will display the number of free
    memory Kbytes left on the device, out of a maximum of 4096.
    4 = Erase key
    This option deletes all programming and returns the SPI key to the unformatted state. This option should not
    be used.
    NOTE:If replacing the software all users, other than the engineer at the keypad in use will be logged out of
    the system. The keypad banner will display a warning of what is happening. The engineer will be
    given a warning that the panel software is about to be replaced. It will take approximately 2 minutes
    to replace the software, during which time the keypads will go off line. Once reprogrammed the
    panel will restart.
    Removing the SPI Key
    CAUTION:Always power down the panel BEFORE removing or connecting the SPI key.
    Failure to do so may result in damage to the SPI key. Never “hot-plug” the SPI
    key.
    1. Remove the SPI Key from the Program Header on the Galaxy 3 Series control panel.
    2. Secure the hinged cap to protect the 10-way connector. 
    						
    							Galaxy 3 Series Programming Manual
    A-1 00 0
    01 1
    02 2
    03 3
    04 4
    05 5
    06 6
    07 7
    08 8
    09 9
    10 space
    11 Å
    12 Ä
    13 A
    14 Æ
    15 B
    16 C
    17 D
    18 E
    19 F
    20 G
    21 space
    22 H
    23 I
    24 J
    25 K
    26 L
    27 M
    28 N
    29 Ø
    30 Ö
    31 O
    32 space
    33 P
    34 Q
    35 R
    36 S
    37 T
    38 U
    39 Ü
    40 V
    41 W
    42 X
    43 space
    44 Y
    45 Z
    46 .
    47 ,
    48 /
    49 -
    50 +
    51 &
    52 (
    53 )
    54 space001 ABOVE
    002 ACCESS
    003 ACCOUNTANT
    004 ACCOUNTANTS
    005 ACCOUNTS
    006 ADMIN.
    007 ALARM
    008 ALERT
    009 ANIMAL
    010 ANNEXE
    011 ARCH
    012 AREA
    013 ARENA
    014 AROUND
    015 ART
    016 ASSEMBLY
    017 ASSISTANT
    018 AT
    019 ATTACK
    020 ATTIC
    021 AUTOMATIC
    022 AUXILIARY
    023 BACK
    024 BAGGAGE
    025 BAKERY
    026 BALCONY
    027 BALLROOM
    028 BANK
    029 BANKING
    030 BAR
    031 BARN
    032 BASEMENT
    033 BATH
    034 BATHROOM
    035 BAY
    036 BEAM
    037 BEDROOM
    038 BEHIND
    039 BELL
    040 BELOW
    041 BENCH
    042 BESIDE
    043 BIOLOGY
    044 BIRD
    045 BLOCK
    046 BLUE
    047 BOARD
    048 BODY
    049 BOILER
    050 BOOTH
    051 BOTTOM
    052 BOX
    053 BOYS
    054 BRANCH
    055 BROOM
    056 BROWN
    057 BUILDING
    058 BUNKER059 B Y
    060 CABINET
    061 CAFE
    062 CALL
    063 CANTEEN
    064 CAR
    065 CARGO
    066 CARPENTER
    067 CARPET
    068 CASH
    069 CASHIER
    070 CEILING
    071 CELL
    072 CELLAR
    073 CENTRAL
    074 CENTRE
    075 CHAIR
    076 CHANGING
    077 CHEMISTRY
    078 CHICKEN
    079 CHURCH
    080 CLASSROOM
    081 CLEANER
    082 CLEANERS
    083 CLEANING
    084 CLERK
    085 CLERKS
    086 COAL
    087 COAT
    088 COIN
    089 COLD
    090 COLLECTION
    091 COMMUNICATOR
    092 COMPUTER
    093 CONFERENCE
    094 CONTAINER
    095 CONTACT
    096 CONSERVATORY
    097 CORNER
    098 CORRIDOR
    099 COUNTER
    100 COURT
    101 COW
    102 CUPBOARD
    103 CURRENCY
    104 DAIRY
    105 DARK-ROOM
    106 DATA
    107 DAY
    108 DEPARTURE
    109 DEPUTY
    110 DEPT.
    111 DESIGN
    112 DESK
    113 DETECTOR
    114 DEVELOPMENT
    115 DEVICE
    116 DIARY117 DINING
    118 DIRECTOR
    119 DIRECTORS
    120 DISPATCH
    121 DOG
    122 DOOR
    123 DOUBLE
    124 DOWNSTAIRS
    125 DRAMA
    126 DRAWER
    127 DRAWING
    128 DRINKS
    129 DRIVE
    130 DRUGS
    131 EAST
    132 ECONOMICS
    133 EDGE
    134 EIGHT
    135 EIGHTEEN
    136 EIGHTY
    137 ELECTRIC
    138 ELECTRICIAN
    139 ELECTRONICS
    140 EMERGENCY
    141 END
    142 ENGINE
    143 ENGINEER
    144 ENGINEERS
    145 ENGLISH
    146 ENTRANCE
    147 ENTRY
    148 EQUIPMENT
    149 ESCAPE
    150 ESCALATOR
    151 EXIT
    152 EXPORT
    153 EXTERNAL
    154 FACTORY
    155 FAILURE
    156 FAR
    157 FARM
    158 FAX
    159 FEED
    160 FEMALE
    161 FENCE
    162 FIELD
    163 FIFTEEN
    164 FIFTY
    165 FLING
    166 FIRE
    167 FIRST
    168 FIRST-AID
    169 FISH
    170 FIVE
    171 FLAT
    172 FLOOR
    173 FOR
    Appendix A:  Library
    Library 
    						
    							Galaxy 3 Series Programming Manual
    A-2 174 FOREIGN
    175 FORTY
    176 FOUNTAIN
    177 FOUR
    178 FREEZER
    179 FRENCH
    180 FRIDGE
    181 FROM
    182 FRONT
    183 GAMES
    184 GARAGE
    185 GARDEN
    186 GATE
    187 GENTS
    188 GEOGRAPHY
    189 GERMAN
    190 GIRLS
    191 GLASS
    192 GOLD
    193 GOODS
    194 GREAT
    195 GREEN
    196 GROCERY
    197 GROUND
    198 GROUNDS
    199 GROUNDSMAN
    200 GROUP
    201 GUARD
    202 GUN
    203 GYM
    204 HALL
    205 HAND
    206 HANGER
    207 HEAD
    208 HEAT
    209 HEATER
    210 HIGH
    211 HISTORY
    212 HOME
    213 HORSE
    214 HOT
    215 HOUSE
    216 ICE
    217 IN
    218 INDUSTRIAL
    219 INFANT
    220 INFANTS
    221 INFORMATION
    222 INFRARED
    223 INSIDE
    224 INSTRUCTORS
    225 INTERIOR
    226 INTO
    227 IRON
    228 ISOLATION
    229 IT
    230 ITALIAN
    231 JANITOR
    232 JANITORS
    233 JUDGE
    234 JUNIOR235 JUST
    236 KEEP
    237 KEYPAD
    238 KITCHEN
    239 LAB
    240 LADIES
    241 LANDING
    242 LAST
    243 LATIN
    244 LAUNDRY
    245 LAVATORY
    246 LAWN
    247 LEAST
    248 LECTURE
    249 LEFT
    250 LEVEL
    251 L.H.S.
    252 LIBRARY
    253 LIFT
    254 LIGHT
    255 LINE
    256 LITTLE
    257 LOADING
    258 LOBBY
    259 LOCK
    260 LOFT
    261 LORRY
    262 LOUNGE
    263 LOW
    264 LUNCH
    265 MACHINE
    266 MAGNETIC
    267 MAIN
    268 MAJOR
    269 MALE
    270 MAN
    271 MANAGER
    272 MANAGERS
    273 MASTER
    274 MAT
    275 MATHS
    276 MEDICAL
    277 MEN
    278 MESS
    279 METAL
    280 METER
    281 MEZZANINE
    282 MICROWAVE
    283 MIDDLE
    284 MILK
    285 MINOR
    286 MOBILE
    287 MODEL
    288 MONITOR
    289 MOULDING
    290 MOVEMENT
    291 NEAR
    292 NEW
    293 NEXT
    294 NIGHT
    295 NINE296 NINETEEN
    297 NINETY
    298 NODE
    299 NOISE
    300 NURSE
    301 NURSERY
    302 NORTH
    303 OF
    304 OFFICE
    305 OFFICER
    306 OFFICERS
    307 OFFICES
    308 OIL
    309 ON
    310 ONE
    311 OPEN
    312 ORANGE
    313 OUT
    314 OUTER
    315 OUTSIDE
    316 OVAL
    317 OVER
    318 P.A. BUTTON
    319 PACKING
    320 PAINT
    321 PANEL
    322 PANIC
    323 PANTRY
    324 PARCEL
    325 PARK
    326 PARTITION
    327 PASSIVE
    328 PATH
    329 PATIO
    330 PEN
    331 PENTHOUSE
    332 PERIMETER
    333 PERSONAL
    334 PERSONNEL
    335 PHONE
    336 PHYSICS
    337 PIG
    338 PIR
    339 PIR BY
    340 PIR IN
    341 PIR ON
    342 PLACE
    343 PLANT
    344 PLAY
    345 PLAZA
    346 PLUMBER
    347 PLUMBERS
    348 POINT
    349 POND
    350 POOL
    351 PORCH
    352 POST
    353 POWER
    354 PRESSURE
    355 PRIMARY
    356 PRIME
    Library (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    A-3 357 PRINT
    358 PROCESSING
    359 PRODUCTION
    360 PUBLIC
    361 PURCHASING
    362 PURPLE
    363 QUALITY
    364 QUANTITY
    365 QUIET
    366 QUICK
    367 RANGE
    368 READING
    369 REAR
    370 RECEPTION
    371 RECORDS
    372 RECTOR
    373 RECTORS
    374 RED
    375 REED
    376 REFECTORY
    377 REMOTE
    378 REPAIR
    379 RESEARCH
    380 REST
    381 RESTAURANT
    382 REVOLVING
    383 RIGHT
    384 R.H.S.
    385 ROLLER
    386 ROOF
    387 ROOM
    388 ROUND
    389 RUN
    390 SAFE
    391 SALES
    392 SCAN
    393 SCANNER
    394 SCANNERS
    395 SCANNING
    396 SCREEN
    397 SEA
    398 SECOND
    399 SECURE
    400 SECRETARIES
    401 SECRETARY
    402 SECTION
    403 SECURITY
    404 SENSOR
    405 SEVEN
    406 SEVENTEEN
    407 SEVENTY
    408 SHACK
    409 SHAFT
    410 SHED
    411 SHEEP
    412 SHOP
    413 SHOWROOM
    414 SHORT
    415 SHOWER
    416 SHUTTER
    417 SIDE418 SILENT
    419 SILVER
    420 SITE
    421 SITTING
    422 SIX
    423 SIXTEEN
    424 SIXTY
    425 SLIDING
    426 SMOKE
    427 SOFTWARE
    428 SOLITARY
    429 SOUND
    430 SOUTH
    431 SPANISH
    432 SPRAY
    433 SPRING
    434 SQUARE
    435 SQUASH
    436 STABLE
    437 STADIUM
    438 STAFF
    439 STAIRS
    440 STAIRWELL
    441 STALLS
    442 STAND
    443 START
    444 STATION
    445 STOP
    446 STORE
    447 STORES
    448 STROBE
    449 STRONG
    450 STUDY
    451 SUITE
    452 SUMMER
    453 SUNDAY
    454 SUPPLY
    455 SURGERY
    456 SWIMMING
    457 SWITCH
    458 SYSTEM
    459 TABLE
    460 TALL
    461 TAMPER
    462 TEA
    463 TEACHER
    464 TECHNICAL
    465 TECHNICIAN
    466 TELLER
    467 TEN
    468 TENNIS
    469 TEST
    470 THE
    471 THEATRE
    472 THEN
    473 THIRTEEN
    474 THIRTY
    475 THREE
    476 TICKET
    477 TILL
    478 TO479 TOILET
    480 TOOL
    481 TOP
    482 TRACK
    483 TRACTOR
    484 TRADE
    485 TRAILER
    486 TRAIN
    487 TRAINING
    488 TRANSPORT
    489 TRAP
    490 T.V.
    491 TWELVE
    492 TWENTY
    493 TWIN
    494 TWO
    495 TYPE
    496 TYPING
    497 TYRE
    498 ULTRASONIC
    499 UNDER
    500 UNIT
    501 UP
    502 UPPER
    503 UPSTAIRS
    504 USER
    505 UTILITY
    506 VAN
    507 VARIABLE
    508 VAULT
    509 VENTILATOR
    510 VISUAL
    511 VOLTAGE
    512 WAITING
    513 WALK
    514 WALL
    515 WARD
    516 WAREHOUSE
    517 WASH
    518 WATER
    519 WAY
    520 W.C.
    521 WEAPON
    522 WEEKEND
    523 WEST
    524 WINDOW
    525 WINTER
    526 WITH
    527 WOOD
    528 WOODWORK
    529 WORK
    530 WORKS
    531 WORKSHOP
    532 X-RAY
    533 YARD
    534 YEAR
    535 YELLOW
    536 ZERO
    537 ZONE
    538 ZOO
    Library (cont’d) 
    						
    							Galaxy 3 Series Programming Manual
    A-4 
    						
    							Galaxy 3 Series Programming Manual
    B-1
    Appendix B:  SIA and Contact ID Event Codes
    Event Codes
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event DescriptionTrigger ID Event
    A - Alarm Cause
    AC Alarm CauseALM CAUSEUser report alarm causeUSER A LWAY S  T RNone
    A - AC Power
    AR AC Restoral AC FAIL- AC Fail zone restoredZONE 13.ELEC.ST 301
    CU-AC- Control Unit AC restred ZONE13.ELEC.ST 301
    AC FAIL- Module AC fail restored MOD.13.ELEC.ST 301
    STAND LOW- Standby Battery Low MOD13.ELEC.ST 301
    CU FUSE- Control Unit fuse rest. MISC  9.TAMPER 300
    13. ELEC.ST
    AT AC Trouble AC FAIL+ AC Fail zone troubleZONE 13.ELEC.ST 301
    CU-AC+ Control Unit AC trouble ZONE13.ELEC.ST 301
    AC FAIL+ Module AC fail trouble MOD.13.ELEC.ST 301
    STAND LOW+ Standby Battery Low MOD 13.ELEC ST 301
    CU FUSE+ Control Unit fuse trouble MISC 9. TAMPER 300
    13.ELEC ST
    FUSE AUX1 Aux1 fuse trouble MOD9.TAMPER 300
    13.ELEC ST
    FUSE AUX2 Aux2 fuse trouble MOD9.TAMPER 300
    13.ELEC ST
    FUSE BELL Bell fuse trouble MOD9.TAMPER 300
    13.ELEC ST
    B - Burglary
    BA Burglary Alarm ENTRY Entry zone alarm ZONE NONE 150
    EXIT+ Exit zone alarm ZONE 2.INTRUDE 134
    INTRUDER+ Intruder zone alarm ZONE 2.INTRUDE 130
    24 HOURS+ 24 hour zone alarm ZONE 3.24 HOURS 135
    SECURITY+ Security zone alarm ZONE4.SECURITY 135
    DUAL+ Dual zone alarm ZONE 2.INTRUDE 130
    FINAL Final zone alarm ZONE NONE 150
    SEC FINAL+ Secure final zone alarm ZONE 4.SECURITY 134
    PRT FINAL+ Part final zone alarm ZONE 2.INTRUDE 134
    PRT ENTRY+ Part entry zone alarm ZONE 2.INTRUDE 134
    BEAM PAIR+ Beam pair zone alarm ZONE 2.INTRUDE 130
    VIDEO+ Video zone alarm ZONE 2.INTRUDE 130
    VIDEO EXT+ Video exit zone alarm ZONE 2.INTRUDE 130
    CUSTOM A+ Custom A zone alarm ZONE 5.CUS ZON 130
    CUSTOM B+ Custom B zone alarm ZONE 5.CUS ZON 130
    MASK+Mask zone alarmZONE 4.SECURITY 135
    INT DELAY Intruder Delay alarm ZONE 2.INTRUDE 150
    URGENT+ Urgent zone alarm ZONE 3.24 HOURS 130
    VIBRATION+Vibration zone alarm ZONE 2.INTRUDE 133
    ATM-1+ ATM-1 zone alarm ZONE 3.24 HOURS 133
    ATM-2+ ATM-2 zone alarm ZONE 3.24 HOURS 133
    ATM-3+ ATM-3 zone alarm ZONE 3.24 HOURS 133
    ATM-4+ ATM-4 zone alarm ZONE 3.24 HOURS 133
    ALARM EXT+ Extend zone alarm ZONE 3.24 HOURS 130
    T/O BURGL+ Entry timeout with zone ZONE 2.INTRUDE 134 
    						
    							Galaxy 3 Series Programming Manual
    B-2
    Event Codes (cont’d)
    Ev SIA Event Galaxy Log Galaxy Log Event Ev Type Galaxy Contact
    Description Event DescriptionTrigger ID Event
    BB Burg BypassOMITTEDZone omittedZONE 8.OMIT 5 7 3
    FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
    GRP OMIT+ Group omitted USER 8.OMIT 574
    OMIT VIBS Omit Vibration zone EVENT 8.OMIT 572
    OMIT-ATM1+ Omit ATM-1 zone EVENT8.OMIT 572
    OMIT-ATM2+ Omit ATM-2 zone EVENT8.OMIT 572
    OMIT-ATM3+ Omit ATM-3 zone EVENT8.OMIT 572
    OMIT-ATM4+ Omit ATM-4 zone EVENT8.OMIT 572
    BC Burg Cancel KSW CANCLKeyswitch Cancel ZONE11.RESET 406
    CANCELCancel by userUSER 11.RESET 4 0 6
    BF Intruder HighINTR HIGHIntruder zone alarmZONE 2. INTRUDE 1 3 0
    BJ Burg Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
    HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
    RF SUPER- RF Supervision FailureZONE15.TROUBL 381
    BL Intruder LowINTR LOWIntruder zone alarmZONE 2. INTRUDE 1 3 0
    BR Burglary RestEXIT-Exit zone type restoredZONE2.INTRUDE 1 3 4
    18.ZN RESTO
    INTRUDER- Intruder zone restored ZONE 2.INTRUDE 130
    18.ZN RESTO
    24 HOURS- 24 hour zone restored ZONE 3.24 HOURS 135
    18.ZN RESTO
    SECURITY- Security zone restored ZONE 4.SECURITY 135
    18.ZN RESTO
    DUAL- Dual zone restored ZONE 2.INTRUDE 130
    18.ZN RESTO
    SEC FINAL- Secure final zone rest. ZONE 4.SECURITY 134
    18.ZN RESTO
    PRT FINAL- Part final zone restored ZONE 2.INTRUDE 134
    18.ZN RESTO
    PRT ENTRY- Part entry zone restored ZONE 2.INTRUDE 134
    18.ZN RESTO
    BEAM PAIR- Beam pair zone rest. ZONE 2.INTRUDE 130
    18.ZN RESTO
    VIDEO- Video zone restored ZONE 2.INTRUDE 130
    18.ZN RESTO
    VIDEO EXT- Video exit zone rest. ZONE 2.INTRUDE 130
    18.ZN RESTO
    CUSTOM A- Custom A zone rest. ZONE 5.CUS ZON 130
    18.ZN RESTO
    CUSTOM B- Custom B zone rest. ZONE 5.CUS ZON 130
    18.ZN RESTO
    MASK- Mask zone restored ZONE4.SECURITY 135
    18.ZN RESTO
    INT ALARM- Intruder Delay restored ZONE 2.INTRUDE 130
    18.ZN RESTO
    URGENT- Urgent zone restored ZONE 3.24 HOURS 130
    18.ZN RESTO
    VIBRATION- Vibration zone restored ZONE 2.INTRUDE 133
    18.ZN RESTO 
    						
    All Honeywell manuals Comments (0)