–31 – Arming All Protection (With Entry Delay ON) Using the 2 AWAY Key Use this key when no one will be staying on the premises. When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm. You may also reenter through the entrance door, but must disarm the system within the entry delay period or an alarm will occur. Close all perimeter windows and doors before arming (see CHECKING FOR OPEN ZONES section) AWAY 1. Enter your security code and press 2 . 2. ARMED **AWAY** YOU MAY EXIT NOW The keypad will beep twice and will display the armed message. Note: The YOU MAY EXIT NOW portion of the message disappears when exit delay expires.
– 32 – Arming All Protection (With Entry Delay OFF) Using the 4 MAXIMUM Key Use this key when the premises will be vacant for extended periods of time such as vacations, etc., or when no one will be moving through protected interior areas. When armed in MAXIMUM mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm, but an alarm will be sounded as soon as someone reenters. Close all perimeter windows and doors before arming (see CHECKING FOR OPEN ZONES section). MAXIMUM 1. Enter your security code and press 4 . 2. ARMED *MAXIMUM* YOU MAY EXIT NOW The keypad will beep twice and will display the armed message. Note: The YOU MAY EXIT NOW portion of the message disappears when exit delay expires.
–33 – Disarming And Silencing Alarms Using the 1 OFF Key The OFF key is used to disarm the system and to silence alarm and trouble sounds. See SUMMARY OF AUDIBLE NOTIFICATION section for information which will help you to distinguish between FIRE and BURGLARY alarm sounds. IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the keypad will beep rapidly upon entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. To disarm the system and silence burglary or fire alarms: OFF 1. Enter your security code and press 1 . DISARMED READY TO ARM 2. The Ready message will be displayed (if no alarms have occurred while armed) and the keypad will beep once to confirm that the system is disarmed. Memory of Alarm The keypad displays the zone number and type of alarm for any zone that has an alarm condition. These messages will remain displayed until cleared by a user. If an alarm has occurred, note the zone number displayed on the keypad and repeat step 1 above to clear the Memory of Alarm and restore the Ready message display. If the Ready message will not display, go to the displayed zone and remedy the fault (close windows, etc.). If the fault cannot be remedied, notify the alarm agency. If the system was armed when the alarm occurred, repeat step 1 twice: once to disarm the system, a second time to clear the display.
– 34 – Using The Keyswitch General Your system may be equipped with a keyswitch for use when arming and disarming a partition. A red and green light on the keyswitch plate indicate the status of your system as follows: Green Light: Lights when the system is disarmed and ready to be armed (no open zones). If the system is disarmed and the green light is off, it indicates the system is not ready (one or more zones are open). Red Light: Lights when system is armed or memory of alarm exists. Lit Steady: Partition is armed in AWAY mode. Slow Flashing: Partition is armed in STAY mode. Rapid Flashing: Memory of alarm, indicating an alarm has occurred . Arming To arm in the AWAY mode, turn the key to the right for 1/2 second and release. Keypads will beep twice and the red light will stay on steady. To arm in the STAY mode, turn the key to the right and hold for longer than 3 seconds, then release. Keypads will beep three times and the red light will flash slowly. Disarming To disarm the partition, turn the key to the right and release. If an alarm has occurred, the red light will be flashing rapidly (memory of alarm). GREEN RED
–35 – Chime Mode Using the 9 Key Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the Keypad whenever a protected perimeter door or window is opened, and the Not Ready message will be displayed. Pressing the READY key will display the open protection points. Note that Chime mode can be activated only when the system is disarmed. 1. To turn Chime Mode on, enter the security code and press 9 . CHIME MODE ON The CHIME MODE ON message will appear for about two seconds then disappear. To display this message again (to determine whether chime mode is on or off), simply press and hold down the CHIME key for 5 seconds. 2. To turn Chime Mode off, enter the security code and press 9 again. CHIME MODE OFF The CHIME MODE OFF message will appear for about two seconds then disappear. To display this message again (to determine whether chime mode is on or off), simply press and hold down the CHIME key for 5 seconds.
– 36 – Viewing Alarm Company Messages General Information Users of the system may periodically receive messages on their display screens from their monitoring agency or installer. When a message is waiting to be viewed, the message shown below will appear. MESSAGE. PRESS 0 FOR 5 SECS. 1. Press and hold down 0 key for 5 seconds. 2. The message could take up to four screens to display all the information available. NOTE: Any message sent by the central station downloader may be viewed at any partition’s keypad.
–37 – Panic Keys (For Manually Activating Silent And/Or Audible Alarms) Using Panic Keys Your system may have been programmed to use special key combinations to manually activate panic functions. The functions that might be programmed are Silent Emergency, Audible Emergency, Personal Emergency, and Fire. See your installer for the function(s) that may have been programmed for your system. Active Panic Functions (Your installer should note which function(s) is active in your system.) Keys Zone Function 1 and * 95 3 and # 96 * and # 99 A 95 B 99 C 96 To use a paired key panic function, simply press both keys of the assigned pair at the same time. If your keypad(s) have lettered keys for panic functions, press the designated key and hold down for at least 2 seconds to activate the panic function. A silent emergency sends a silent alarm signal to the central station, but there will be no audible alarms or visual displays. An audible emergency sends an emergency message to the central station (if connected) and will sound a loud, steady alarm at your keypad and at any external sounders that may be connected (ALARM plus a zone number would also be displayed). A personal emergency alarm sends an emergency message to the central station (if connected) and will sound at Keypads, but not at external bells or sirens. (ALARM plus a zone number would also be displayed.) A fire alarm sends a fire alarm message to the central station and will uniquely sound external bells and sirens (FIRE plus a zone number would also be displayed).
– 38 – Speed Key (Macros) General Information The “D” key can be used to activate a string of commands up to 16 keystrokes each. These commands are known as a macro and are stored in the system’s memory. Typical Speed Key functions include: • Arming sequences that involve first bypassing certain zones before arming. • Seldom used but repeatable sequences. • Relay activation sequences. NOTE: If a speedkey function includes an arming sequence and the user executing it has global arming, all partitions the user can global arm will arm. Defining To program a macro, enter your user code + [#] + [D]. The following appears: ENTER SPEED KEY D existing sequence displayed Enter up to 16 keystrokes. A Speed Key sequence can include different commands. Press the D key to separate different commands. For example, you may want to perform the following sequence. GOTO partition 2...................... Enter *2 Bypass zones 10 & 11 ............... Press bypass [6], then the zone numbers 010 & 011 Arm in maximum mode............ Press maximum [4] key Return to partition 1 ................ Enter *1 To program that Speed Key sequence, type the following: *2 D 6010011 D 4D *1 DD Note that the D key is pressed after each command. Press D twice to complete the entry and exit. NOTE: When defining the Speed Key sequence, do not use the [#] key to represent Quick Arming. The system uses the code entered in response to the prompt to initiate commands in a Speed Key sequence, so the quick arm key is unnecessary. The system interprets the use of the [#] key in a Speed Key sequence as its designated function only.
– 39 – Speed Key (Macros) (cont’d) Executing To activate a Speed Key, press and hold down the [D] key for 2 seconds. If a user code is required for any part of the Speed Key sequence, the following prompt appears. Otherwise, the Speed Key sequence automatically begins. ENTER USER CODE Enter your user code. The defined Speed Key sequence will begin automatically.
– 40 – Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momentarily or for a specific period of time, using a keypad command. Ask your installer if this has been done in our system. Executing There are several entries that can be entered at the keypad to activate this command: Enter your security code + [0]. The door will unlock for 2 seconds.