Page 51
– 51 – Trouble Conditions Typical Trouble Displays The word CHECK on the Keypad’s display, accompanied by a rapid beeping at the Keypad, indicates that there is a trouble condition in the system. To silence the beeping sound for trouble conditions, press any key. • A display of “CHECK” accompanied by a display of CALL SERVICE indicates that a problem exists with the system that eliminates some of the protection. CALL FOR SERVICE IMMEDIATELY. • A display of “CHECK” accompanied by a...
Page 52
– 52 – Trouble Conditions (cont’d) Power Failure If the POWER indicator is off, operating power for the system has stopped and is inoperative. CALL FOR SERVICE IMMEDIATELY. If the POWER indicator is on, but the message AC LOSS is displayed, the Keypad is operating on battery power only. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. CALL FOR SERVICE IMMEDIATELY if AC power cannot be restored. Non-Alpha Keypad Displays The...
Page 53
– 53 – Recommendations For Proper Protection The following recommendations for the location of fire and burglary detection devices help provide proper coverage for the protected premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association’s (NFPA) Standard #72 noted below. Early warning fire detection is best achieved by the installation of fire...
Page 54
– 54 – Recommendations For Proper Protection (cont’d) In addition, we recommend the following: Install a smoke detector inside every bedroom where a smoker sleeps. Install a smoke detector inside bedrooms where electrical appliances (such as portable heaters, air conditioners or humidifiers) are used. Install a smoke detector inside every bedroom where someone sleeps with the door partly or completely closed. Smoke could be blocked by the closed door. Also, an alarm in the hallway...
Page 55
– 55 – Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1. Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants. 2. Determine two means of escape from each room. One path of escape should lead to the door that permits normal exit from the building. The other may be a window, should your path be impassable....
Page 56
– 56 – Maintaining Your System Taking Care of Your System The components of your security system are designed to be as free of maintenance as possible. However, there are some things you can do to make sure that your system is in reliable working condition. 1. Test your system weekly. 2. Test the system after any alarm occurs (see TESTING THE SYSTEM). Replacing Batteries in Wireless Sensors Wireless sensors may not have been used in your security system Each wireless sensor in your...
Page 57
– 57 – Maintaining Your System (cont’d) Silencing Low Battery Warning Tones at the Keypad The keypad’s warning tones can be silenced by performing an OFF sequence (code plus OFF key), but the Keypads low battery message display will remain on as a reminder that you have a low battery condition in one or more of your sensors. When you replace the weak battery with a fresh one, the sensor will send a good battery signal to the control as soon as the sensor is activated (opening/closing of door,...
Page 58
– 58 – Quick Guide To System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press [✱]. To view faulted zones when is system not ready Display All Descriptors Press and hold [✱] for 5 seconds. Displays all alpha descriptors programmed by installer. Arm System Enter code. Press arming key desired (AWAY, STAY, INSTANT, MAXIMUM). Arms system in mode selected. Disarm System Enter code. Press OFF [1]. Disarms system and silences alarms. Bypass Zones Enter code. Press BYPASS [6]....
Page 59
– 59 – Quick Guide To System Functions (cont’d) FUNCTION PROCEDURE COMMENTS Delete a User Enter master/manager code. Press CODE [8]. Enter user no. to be deleted. Enter master/manager code. Press 1 (Yes) at prompt. Master & Manager level users can delete users. A user can only be deleted by a user with higher authority level. Enter security code. Press [#] Enter 71 or 72. Activate output device as programmed. Control Output Device Enter security code. Press [#] Enter 70. Activate...
Page 60
– 60 – Summary Of Audible Notification (Alpha Display Keypads) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE is displayed; descriptor of zone in alarm is displayed. LOUD, CONTINUOUS* Keypad & External BURGLARY/AUDIBLE EMERGENCY ALARM ALARM is displayed; descriptor of zone in alarm is also displayed. ONE SHORT BEEP (not repeated) Keypad only a. SYSTEM DISARM b. SYSTEM ARMING ATTEMPT WITH AN OPEN ZONE. c. BYPASS VERIFY a. DISARMED/READY TO ARM...