Honeywell 6400 D Manual
Have a look at the manual Honeywell 6400 D Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
RTH6400 Programmable Thermostat 9 69-2211EF—05 Save money by setting program schedules It’s easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for weekdays, Saturday and Sunday. Set to the time you awaken and the temperature you want during the morning, until you leave for the day. Set to the time you leave home and the temperature you want while you are away (usually an energy-saving level). Set to the time you return home and the temperature you want during the evening, until bedtime. Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level). WAKE6:00 am 70 ° LEAVE8:00 am 62 ° RETURN6:00 pm 70 ° SLEEP10:00 pm 62 °
Operating Manual 69-2211EF—05 10 Energy saving settings for maximum cost savings This thermostat is pre-set to use energy saving program settings. We recommend these settings, since they can reduce your heating/cooling expenses. (See next page to adjust times and temperatures of each time period.) Wake(6:00 am) Leave(8:00 am) Return(6:00 pm) Sleep(10:00 pm) Cool (Mon-Fri)Heat (Mon-Fri)Heat (Sat-Sun)Cool (Sat-Sun) 70 °75 °70 °75 ° 62 °83 °62 ° [Or cancel period]83 ° [Or cancel period] 70 °75 °70 ° [Or cancel period]75 ° [Or cancel period] 62 °78 °62 °78 °
RTH6400 Programmable Thermostat 11 69-2211EF—05 To adjust program schedules 1. Press SET CLOCK/DAY/SCHEDULE, then SET SCHEDULE. 2. Press s or t to set your weekday Wake time (Mon–Fri), then press NEXT. 3. Press s or t to set the temperature for this time period, then press NEXT. 4. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period. 5. Press NEXT to set Saturday time periods. 6. Press NEXT to set Sunday time periods, then press DONE to save & exit. Note: Make sure the thermostat is set to the system you want to program (Heat or Cool). Note: You can press CANCEL PERIOD to eliminate unwanted time periods (except Wake).M28409 Set Clock/Day / Schedul eAuto Fan System Heat Set Day Set Schedul e Done Mon Tue We d Thu Fri Leav e Set Schedule Heat Setting AM 628 : 00 DoneCancelPeriodNext
Operating Manual 69-2211EF—05 12 M28410 Heat Setting Inside AM 69756: 30 Te mporary Run Schedule Auto Fan System Heat Program schedule override (temporary) Press s or t to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. The new temperature will be maintained only until the next programmed time period begins (see page 10). For example, if you want to turn up the heat early in the morning, it will automatically be lowered when you leave for the day. To cancel the temporary setting at any time, press RUN SCHEDULE. Press to cancel temporary setting and resume program schedule. Note: Make sure the thermostat is set to the system you want to control (heat or cool). Press to temporarily adjust temperature.
RTH6400 Programmable Thermostat 13 69-2211EF—05 M28411 Heat Setting Inside AM 69756: 30 Run Schedule Auto Fan System Heat Hold Program schedule override (permanent) Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods. The “Hold” feature turns off the pro- gram schedule and allows you to adjust the thermostat manually, as needed. Whatever temperature you set will be maintained 24 hours a day until you manually change it, or press RUN SCHEDULE to cancel “Hold” and resume the programmed schedule. Press to cancel “Hold” setting and resume program schedule. Note: Make sure the thermostat is set to the system you want to control (heat or cool). Press to permanently adjust temperature.
Operating Manual 69-2211EF—05 14 Use this feature in climates where both air conditioning and heating are used on t\ he same day. When the system mode is in Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. While in the Auto mode, if a schedule override takes place (temporarily or permanently) the thermostat will automatically adjust the cooling and heating settings to mai\ ntain a 3-degree separation between the cool and heat settings. For example, if the heat temperature is raised to where it gets within 3-dgrees of the cool setting, the display will show an up arrow next to “cool” to show the thermostat is raising the cool setting up to maintain a 3-dgreee separation. Press the Select Heat/Cool button to select between the heat and cool to view/adjust either mode. Auto Changeover
RTH6400 Programmable Thermostat 15 69-2211EF—05 If the cool temperature is lowered to where it gets close to the heat setting, an arrow next to heat will show the thermostat is lowering the heat setting down to maintain a 3-degree separation. Auto Changeover CAUTION: To avoid possible compressor damage, do not use Auto Changeover if the outside temperature drops below 50ºF (10ºC). Run Schedule Auto Cool Fan Select Heat/Coo l Heat Setting Inside PM 73731: 05 Te mporary M27477 Press Select Heat/Cool to set the heat or cool tem-perature. The triangle indicates the cool temperature is increasing to maintain 3 degrees between heat and cool settings.
Operating Manual 69-2211EF—05 16 M28412 Cool On Coo l Setting Inside AM75756: 30 Set Clock/Day/ Schedule Auto Fan System Cool Built-in compressor protection This feature helps prevent damage to the com- pressor in your air conditioning or heat pump system. Damage can occur if the compressor is re-started too soon after shutdown. This feature forces the compressor to wait a few minutes before restarting. During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). When the safe wait time has elapsed, the message stops flashing and the compressor turns on. Message flashes until safe restart time has elapsed.
RTH6400 Programmable Thermostat 17 69-2211EF—05 Smart Response® Technology: This feature allows the thermostat to “learn” how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the time you set. For example: Set the Wake time to 6 am, and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6. The message “In Recovery” is displayed when the system is activated before a scheduled time period. Smart Response® Technology M27476 Cool On Coo l Setting Inside AM75756: 38 Set Clock/Day/ Schedule Auto Fan System Cool In Recovery Displays when Smart Response is active.
Operating Manual 69-2211EF—05 18 About your new thermostat M28414 M28413 Replace Battery Battery replacement Install fresh batteries immediately when the REPLACE BATTERY warning begins flashing. The warning flashes about two months before the bat- teries are depleted. Even if the warning does not appear, you should replace batteries once a year, or before leaving home for more than a month. If batteries are inserted within two minutes, the time and day will not have to be reset. All other settings are permanently stored in memory and do not require battery power. Press down and pull to remove. Insert fresh AA alkaline batteries, then reinstall battery holder.