Page 141

8 - 13
Matrix 2 of 5

Matrix 2 of 5 On/Off
Matrix 2 of 5 Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 1-80.  Minimum Default = 4, Maximum Default = 80.
On
*  Off
Minimum Message Length
Maximum Message Length 

Page 142

8 - 14
Code 11

Code 11 On/Off
Check Digits Required
This option sets whether 1 or 2 check digits are required with Code 11 bar codes.  Default = Two Check Digits.
Code 11 Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 1-80.   Minimum Default = 4, Maximum Default = 80.
On
*  Off
One Check Digit
*  Two Check Digits
Minimum Message Length
Maximum Message Length 

Page 143

8 - 15
Code 128

Code 128 On/Off
ISBT 128 Concatenation
In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood informa-
tion in a uniform manner.  The use of ISBT formats requires a paid license. The ISBT 128 Application Specification 
describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to 
its high degree of security and its space-efficient design, 3) a variation of Code 128...

Page 144

8 - 16
Code 128 Append
This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to 
the host computer.  When the scanner encounters a Code 128 bar code with the append trigger character(s), it buffers 
Code 128 bar codes until it reads a Code 128 bar code that does not have the append trigger.  The data is then transmitted 
in the order in which the bar codes were read (FIFO).  Default = On.
Code 128 Code Page
Code pages define the mapping of...

Page 145

8 - 17
GS1-128

GS1-128 On/Off
GS1-128 Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 1-80.   Minimum Default = 1, Maximum Default = 80.
* On
Off
Minimum Message Length
Maximum Message Length 

Page 146

8 - 18
Te l e p e n

Telepen On/Off
Telepen Output
Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII 
(start/stop pattern 1).  When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and 
decodes them as compressed numeric with optional full ASCII (start/stop pattern 2).  Default = AIM Telepen Output.
Telepen Message Length
Scan the bar codes below to change the message length.  Refer to Message...

Page 147

8 - 19
UPC-A

UPC-A On/Off
Note: To convert UPC-A bar codes to EAN-13, see Convert UPC-A to EAN-13on page 8-24.
UPC-A Check Digit
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.  
Default = On.
UPC-A Number System
The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can 
be programmed so it will not transmit it.   Default = On.
*  On
Off
*  On
Off
*  On
Off 

Page 148

8 - 20
UPC-A Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
Default = Off for both 2 Digit and 5 Digit Addenda.
UPC-A Addenda Required
When Required is scanned, the scanner will only read UPC-A bar codes that have addenda.  You must then turn on a 2 or 
5 digit addenda listed on page 8-20.  Default = Not Required.
UPC-A Addenda Separator
When this feature is on, there is a space between the data from the bar code and the data from the addenda.  When turned 
off, there is...

Page 149

8 - 21
UPC-A/EAN-13 with Extended Coupon Code
Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code.  When left on the default setting 
(Off), the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes.  
If you scan the Allow Concatenation code, when the scanner sees the coupon code and the extended coupon code in a single 
scan, it transmits both as one symbologies.  Otherwise, it transmits the first coupon code it reads.  
If you scan the Require...

Page 150

8 - 22
UPC-E0

UPC-E0 On/Off
Most U.P.C. bar codes lead with the 0 number system.  To read these codes, use the UPC-E0 On selection.  If you need to 
read codes that lead with the 1 number system, use UPC-E1 (page 8-24).  Default = On.
UPC-E0 Expand
UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format.  Default = Off.
UPC-E0 Addenda Required
When Required is scanned, the scanner will only read UPC-E bar codes that have addenda.  Default = Not Required.
*  UPC-E0 On
UPC-E0 Off
On
*  Off...