8 - 3
When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a 
check character, but will not transmit the check character with the scanned data.
Codabar Concatenation
Codabar supports symbol concatenation.  When you enable concatenation, the scanner looks for a Codabar symbol having 
a “D” start character, adjacent to a symbol having a “D” stop character.  In this case the two messages are concatenated 
into one with the “D” characters...

Page 132

8 - 4
Code 39
< Default All Code 39 Settings >
Code 39 On/Off
Code 39 Start / Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/
Stop characters.  Default =  Don’t Transmit.
Code 39 Check Character
No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 bar codes...

Page 133

8 - 5
Code 39 Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 0-48.  Minimum Default = 0, Maximum Default = 48.
Code 39 Append
This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to 
the host computer.  When the scanner encounters a Code 39 bar code with the append trigger character(s), it buffers Code 
39 bar...

Page 134

8 - 6
Full ASCII
If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single 
character.  For example:  $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #.  
Default = Off.
Character pairs /M and /N decode as a minus sign and period respectively.
Character pairs /P through /Y decode as 0 through 9.
Code 39 Code Page
Code pages define the mapping of character codes to characters.  If the data...

Page 135

8 - 7
Interleaved 2 of 5
< Default All Interleaved 2 of 5 Settings >
Interleaved 2 of 5 On/Off
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit.
When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a 
check digit, but will not transmit the check digit with the scanned data.  
When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar...

Page 136

8 - 8
NEC 2 of 5
< Default All NEC 2 of 5 Settings >
NEC 2 of 5 On/Off
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit.
When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check 
digit, but will not transmit the check digit with the scanned data.  
When Check Digit is set to Validate and Transmit, the scanner only reads NEC 2 of 5 bar codes printed with a check digit, 
and...

Page 137

8 - 9
NEC 2 of 5 Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 2-80.  Minimum Default = 4, Maximum Default = 80.
Code 93
< Default All Code 93 Settings >
Code 93 On/Off
Code 93 Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 0-80.  Minimum Default...

Page 138

8 - 10
Code 93 Append
This function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to 
the host computer.  When this function is enabled, the scanner stores those Code 93 bar codes that start with a space 
(excluding the start and stop symbols), and does not immediately transmit the data.  The scanner stores the data in the 
order in which the bar codes are read, deleting the first space from each.  The scanner transmits the appended data when 
it...

Page 139

8 - 11
Straight 2 of 5 Industrial (three-bar start/stop)

Straight 2 of 5 Industrial On/Off
Straight 2 of 5 Industrial Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 1-48.  Minimum Default = 4, Maximum Default = 48.
On
*  Off
Minimum Message Length
Maximum Message Length 

Page 140

8 - 12
Straight 2 of 5 IATA (two-bar start/stop)

Straight 2 of 5 IATA On/Off
Straight 2 of 5 IATA Message Length
Scan the bar codes below to change the message length.  Refer to Message Length Description (page 8-1) for additional 
information.  Minimum and Maximum lengths = 1-48.  Minimum Default = 4, Maximum Default = 48.
On
*  Off
Minimum Message Length
Maximum Message Length 
Start reading Honeywell 1900ghd-2 User Manual

Related Manuals for Honeywell 1900ghd-2 User Manual

All Honeywell manuals