Page 21

19
AC APPLICATIONS
The total power requirements (VA) of all appliances connected must
be considered. Appliance and power tool manufacturers usually list
rating information near the model number or serial number. For continuous operation, do not exceed the rated power.
Rated power is: Limit operation requiring maximum power to 30 minutes.
Maximum power is:
Substantial overloading will switch off the AC circuit protector.
Exceeding the time limit for maximum power operation or slightly
overloading the...

Page 22

20
AC OPERATION
OVERLOAD INDICATOR
LIGHT (RED)
OUTPUT INDICATOR
LIGHT (GREEN)
Most motorized appliances require more than their rated wattage for
startup.Plug in the appliance.
Before connecting an appliance to the generator, make sure that it is in
good order and that its electrical rating does not exceed that of the
generator. Then start the generator and connect the appliance power
cord. Determine if the cause is a short circuit in a connected appliance or an
overload. Correct the problem and restart...

Page 23

21
AC PARALLEL OPERATION APPLICATIONS
Substantial overloading that continuously lights the overload indicator
light (red) may damage the generator. Marginal overloading that
temporarily lights the overload indicator light (red) may shorten the
service life of the generator.
For single generator operation, the parallel operation kit must be
removed. Never connect or remove the parallel operation kit when the
generator is running. Use only a Honda approved parallel operation kit (optional
equipment) when...

Page 24

22
Limit operation requiring maximum power to 30 minutes.
Maximum power in parallel operation is:
For continuous operation, do not exceed the rated power.
Rated power in parallel operation is:
The total power requirements (VA) of all appliances connected must
be considered. Appliance and power tool manufacturers usually list
rating information near the model number or serial number.
4.0 kVA
3.2 kVA
——y
y
/yy 

Page 25

23
AC PARALLEL OPERATION
PARALLEL OPERATION KIT
(optional equipment)
Connect the parallel operation kit between the two EU2000i
generators following the instructions supplied with the kit.
If the generators are overloaded (see page ), or if there is a short
circuit in a connected appliance, the overload indicator lights (red) will
go ON. The overload indicator lights (red) will stay ON, and after about
four seconds, current to the connected appliance(s) will shut off, and
the output indicator lights...

Page 26

µ
´µ
24
DC OPERATION
Connecting the battery charging cable (optional equipment):
The battery gives off explosive gases; keep sparks, flames and
cigarettes away. Provide adequate ventilation when charging or using
batteries.
WARNING:
Wash hands after handling.
PUSH OFF
ON
DC CIRCUIT PROTECTORDC RECEPTACLE
When using the DC output, turn the Eco-Throttle switch to the OFF
position.
Before connecting the battery charging cable to a battery that is
installed in a vehicle, disconnect the vehicle battery...

Page 27

µ
´
µ
25
Disconnecting the battery charging cable:
BLACK LEAD
RED LEAD BATTERY CHARGING CABLE
(optional equipment)
An overloaded DC circuit, excessive current draw by the battery, or a
wiring problem will trip the DC circuit protector (PUSH button extends
out). If this happens, wait a few minutes before pushing in the circuit
protector to resume operation. If the DC circuit protector continues to
go OFF, discontinue charging and see your authorized Honda
generator dealer.
Stop the engine.
Disconnect...

Page 28

26
ECO-THROTTLE SYSTEM
OOFFFF
OONN ECO-THROTTLE SWITCH
TM
TM
Appliances with large start-up power demands may not allow the
engine to reach normal operating rpm when they are connected to the
generator. Turn the Eco-Throttle to the OFF position and connect the
appliance to the generator. If the engine still will not reach normal
operating speed, check that the appliance does not exceed the rated
load capacity of the generator.
The Eco-Throttle system is not effective for use with appliances that
require...

Page 29

27
HIGH ALTITUDE OPERATION
At high altitude, the standard carburetor air/fuel mixture will be too
rich. Performance will decrease, and fuel consumption will increase. A
very rich mixture will also foul the spark plug and cause hard starting.
Operation at an altitude that differs from that at which this engine was
certified, for extended periods of time, may increase emissions.
High altitude performance can be improved by specific modifications
to the carburetor. If you always operate your generator at...

Page 30

28 PRE-OPERATION CHECK
ENGINE OIL
AMBIENT TEMPERATURE SAE VISCOSITY GRADES
COVER SCREW
MAINTENANCE
COVER
Check the oil level BEFORE EACH
USE with the generator on a level
surface and the engine stopped.
Use 4-stroke motor oil that meets
or exceeds the requirements for
API service classification SJ or
later (or equivalent). Always check
the API SERVICE label on the oil
container to be sure it includes
the letter SJ or later (or
equivalent).
SAE 10W-30 is recommended for general, all-temperature use....