Hitachi Storage Navigator Modular 2 User Guide
Have a look at the manual Hitachi Storage Navigator Modular 2 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 913 Hitachi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Preinstallation Information2–5 Hitachi Storage Navigator Modular 2 User’s Guide Sun Solaris operating systems Table 2-4 lists the Navigator 2 requirements for management consoles running a supported Sun Solaris operating system. For information about supported Sun Solaris hosts and their requirements, see: • The Hitachi AMS 2100/2300 Getting Started Guide (MK-98DF8152EN) • The Hitachi AMS 2500 Getting Started Guide (MK-97DF8032EN) • The interoperability matrix at http://www.hds.com/products/ interoperability/ Red Hat Linux operating systems Table 2-5 on page 2-6 lists the Navigator 2 requirements for management consoles running a supported Red Hat Linux operating system. For information about supported Red Hat Linux hosts and their requirements, see: • The Hitachi AMS 2100/2300 Getting Started Guide (MK-98DF8152EN) • The Hitachi AMS 2500 Getting Started Guide (MK-97DF8032EN) • The interoperability matrix at http://www.hds.com/products/ interoperability/ Table 2-4: Requirements for Management Consoles Running Sun Solaris ItemRequirement Operating systems • Solaris 8 (SPARC) •Solaris 9 (SPARC) • Solaris 10 (SPARC) • Solaris 10 (x86) • Solaris 10 (x64) Processor • SPARC: 1 GHz (2 GHz or faster recommended) • Solaris 10 (x64): 1.8 GHz (2 GHz or faster recommended) Random Access Memory 1 GB (2 GB or more recommended) Available disk space 1 GB or more Video resolution 800 x 600 dots per inch (1024 x 768 or later recommended), 256 colors or more Browser (with pop-up blockers disabled)• Mozilla v1.7 •Firefox 2 JRE JRE v1.6.0_15
2–6Preinstallation Information Hitachi Storage Navigator Modular 2 User’s Guide Network requirements The management console can be used with the items in Table 2-6. Setting of Linux kernel parameters When you install Hitachi Storage Navigator Modular 2 to Linux, set the Linux kernel parameters. Otherwise, the installer ends without installing the hsoftware. The only exception is if Navigator 2 has already been installed and used in a Hitachi Storage Command Suite Common Component environment. In this case, you do not need to set the Linux kernel parameters. To set the Linux kernel parameters 1. Back up the kernel parameters setting file (/etc/sysctl.conf and /etc/ security/limits.conf). Table 2-5: Requirements for Management Consoles Running Red Hat Linux ItemRequirement Operating systems • Red Hat Enterprise Linux AS 4.0 update 1 • Red Hat Enterprise Linux AS 4.0 update 5 • Red Hat Enterprise Linux 4.0 update 1 • Red Hat Enterprise Linux 4.0 update 5 • Red Hat Enterprise Linux 5.0 update 3 • Red Hat Enterprise Linux 5.0 update 4 Processor 1 GHz (2 GHz or faster recommended) Random Access Memory 1 GB (2 GB or more recommended) Available disk space 1 GB or more Video resolution 800 x 600 dots per inch (1024 x 768 or later recommended), 256 colors or more Browser (with pop-up blockers disabled)Mozilla v1.7 JRE JRE v1.6.0_15 Table 2-6: Network Requirements ItemDescription Network Interface Card (NIC)For supported NICs, see the interoperability matrix at http://www.hds.com/products/interoperability/. Ethernet cable The management ports support Auto-MDI/MDIX technology, allowing you to use either standard (straight- through) or crossover Ethernet cables. Switch or hub • For Fibre Channel networks, use a Fibre Channel switch or hub. • For iSCSI networks, use an iSCSI switch or hub.
Preinstallation Information2–7 Hitachi Storage Navigator Modular 2 User’s Guide 2. Ascertain the IP address of the management console (for example, using ipconfig in a DOS environement). Then change its IP address to 192.168.0. x where x is a number from 1 to 254, excluding 16 and 17. Write this IP address on a piece of paper. You will be prompted for it during the Storage Navigator Modular 2 installation procedure. 3. Disable popup blockers in your Web browser. We also recommend that you disable anti-virus and proxy settings on the management console when installing the Storage Navigator Modular 2 software. 4. To log in to Storage Navigator Modular 2 with a Red Hat Enterprise Linux (RHEL) operating system, modify the kernel settings as follows: • SHMMAX parameter. This parameter defines the maximum size, in bytes, of a single shared memory segment that a Linux process can allocate in its virtual address space. If the RHEL default parameter is larger than both the SNM2 and Database values, you do not need to change it. • SHMALL parameter. This parameter sets the total amount of shared memory pages that can be used system wide. For SNM2, this value must equal the sum of the default value, SNM2, and Database values. • Other parameters. The following parameters follow the same rule as SHMALL and must be the higher of (RHEL current value + value in Navigator 2 column) or the value from the Database value. • kernel.shmmni • kernel.threads-max • kernel.msgmni • kernel.sem (second parameter) • kernel.sem (fourth parameter) • fs.file-max nofile nproc Table 2-7 details recommended values for Linux kernel parameters. Table 2-7: Linux kernel parameters Parameter NameStandard RHEL 5.xSample Customer ValuesStorage Navigator Modular 2SNM2 DatabaseRequired New Value kernel.shmmax 4294967295 4294967295 11542528 20000000 04294967295 kernel.shmall 268435456 268435456 22418432 22418432 22418432 kernel.shmmni 40964096 0 2000 2000 kernel.threads- max65536 122876 184 574 123060 kernel.msgmni 32 32 32 32 64 kernel.sem (Second parameters)32000 32000 80 7200 32080
2–8Preinstallation Information Hitachi Storage Navigator Modular 2 User’s Guide 5. Open the kernel parameters setting file (/etc/sysctl.conf) with a standard text editor and change referring to the following. The parameters are specified using the form, which is [name of parameter]=[value]. Four values separated by space are specified in kernel.sem. Then, the parameter must not exceed the maximum value that OS specifies. The value can be checked by the following command. cat /proc/sys/kernel/shmmax (Case: Check value of kernel.shmmax) The default physical management port IP addresses are set to: • Controller 0:192.168.0.16 • Controller 1: 192.168.0.17 6. Reboot host. kernel.sem (Fourth parameters)128 128 9 1024 1024 fs.file-max 205701 387230 53898 53898 441128 nofile 0 0 572 1344 1344 nproc 0 0 165 512 512 Table 2-7: Linux kernel parameters
Preinstallation Information2–9 Hitachi Storage Navigator Modular 2 User’s Guide Collecting user-supplied items Before installing Navigator 2, be sure you have the following user-supplied items. • Navigator 2 installation CDs or access to the Hitachi Data Systems Web Portal:support.hds.com. • A PC that will act as the management console for managing the storage system using Navigator 2. See Navigator 2 operating environment on page 2-3. • The IP address of each management port on your AMS 2000 Family storage system that will connect to the Navigator 2 management console. Refer to the document for your AMS hardware. • The IP address of the management console. See Getting started (all users) on page 3-2. • The port number used to access Navigator 2 from your browser. The default port is 1099. • The password you will use to replace the default system account password. • License keys required by each program product you want to use. See Obtaining license keys on page 2-12. Installing Java runtime If the management console does not have the required version of JRE installed, as indicated under Navigator 2 operating environment on page 2- 3), use the procedures in the following sections to download and install it. Downloading and installing JRE You can download JRE from the following site and install it by following the on-screen prompts: http://java.com/en/download/ After installing JRE v6.0, refer to the appropriate section that follows to complete the installation for the operating system running on the management console. Clients running Microsoft Windows To install JRE if your management console runs Microsoft Windows 1. Click the Windows Start menu, point to Settings, and click Control Panel. The Windows Control Panel appears. 2. In the Windows Control Panel, double-click Java Control Panel. The Java Control Panel appears. 3. Click the Java tab. The Java tab appears (see Figure 2-1 on page 2-10).
2–10Preinstallation Information Hitachi Storage Navigator Modular 2 User’s Guide Figure 2-1: Java Tab 4. Click View in the Java Applet Runtime Settings section. The Java Runtime Settings dialog box appears. 5. In the Java Runtime Parameters field, type -Xmx192m (see Figure 2-2). Figure 2-2: Java Runtime Settings Dialog Box 6. Click OK to exit the Java Runtime Settings window.
Preinstallation Information2–11 Hitachi Storage Navigator Modular 2 User’s Guide 7. Click OK in the Java tab to close the Java Control Panel window. 8. Close the Windows Control Panel. Clients running Solaris or Linux To install JRE if your management console runs a supported Solaris or Linux operating system 1. From an XWindows terminal, execute the / bin/jcontrol to run the Java Control Panel. 2. Click View in the Java Applet Runtime Settings section. The Java Runtime Settings window appears. 3. In the Java Runtime Parameters field, type -Xmx192m. 4. Click OK to exit the Java Runtime Settings window. 5. Click OK in the Java tab to close the Java Control Panel window. Firewall considerations A firewalls main purpose is to block incoming unsolicited connection attempts to your network. If the AMS 2000 Family storage system is used within an environment that uses a firewall, there will be times when the storage system’s outbound connections will need to traverse the firewall. The storage systems incoming indication ports are ephemeral, with the system randomly selecting the first available open port that is not being used by another Transmission Control Protocol (TCP) application. To permit outbound connections from the storage system, you must either disable the firewall or create or revise a source-based firewall rule (not a port-based rule), so that items coming from the storage system are allowed to traverse the firewall. Firewalls should be disabled when installing Navigator 2 (refer to the documentation for your firewall). After the installation completes, you can turn on your firewall. If you use Windows firewall, the Navigator 2 installer automatically registers the Navigator 2 file and Command Suite Common Components as exceptions to the firewall. Therefore, before you install Navigator 2, confirm that no security problems exist. Anti-virus software considerations Anti-virus programs, except Microsoft Windows’ built-in firewall, must be disabled before installing Navigator 2. In addition, Navigator 2 cannot operate with firewalls that can terminate local host socket connections. As a result, configure your anti-virus software to prevent socket connections from being terminated at the local host (refer to the documentation for your anti-virus software). NOTE:For outgoing traffic from the storage system’s management port, there are no fixed port numbers (ports are ephemeral), so all ports should be open for traffic from the storage system management port.
2–12Preinstallation Information Hitachi Storage Navigator Modular 2 User’s Guide Obtaining license keys Some Program Products require a license key before you can use them. Typically, the license key required to activate these products is furnished with the product. We recommend that you have these license keys available before you activate the Program Products that require them. If you do not have license keys for the Program Products, please contact technical support. Reviewing technical guidelines The following sections cover technical guidelines to review before installing Navigator 2 on a management console. Windows operating systems Installation prerequisites Before installing Navigator 2 on a management console running one of the supported Microsoft Windows operating systems in Table 2-3 on page 2-4: • Log in to Windows as an Administrator or a member of the Administrators group. • Disable power management through Windows to prevent the host from entering suspension mode. Selecting a destination folder During the Navigation 2 installation, you are prompted to select a destination folder. You can accept the default destination folder or select a different destination folder. If you select a different destination folder, be sure the folder complies with the following requirements: • The folder name should only contain the characters A to Z, a to z, 0 to 9, hash mark (#), plus sign (+), hyphen (-), period (.), at mark (@), underscore (_), and the space character. • A space character cannot appear at the beginning or end of a folder name. • The path name cannot contain any names reserved by the operating system (for example, CON, AUX, NUL, PRN, CLOCK$, COM1 to COM9, and LPT1 to LPT9). • The path to the destination folder cannot exceed 100 characters. • The path to the destination folder cannot be a route to a drive. Otherwise, the installer displays the following error message during the installation. • Do not specify a Uniform Naming Convention (UNC) path.
Preinstallation Information2–13 Hitachi Storage Navigator Modular 2 User’s Guide Solaris and Linux operating systems Installation prerequisites Before installing Navigator 2 on a management console running one of the supported Solaris and Linux operating systems in Table 2-3 on page 2-4: • Log on as a root user. •If /opt exists, the normal directory is required, not the symbolic link. However, the file system can be mounted as a mount point. • For Solaris v10 (SPARC), apply the appropriate patch. • Apply patch 120664-xx (where xx is 01 or later). • Apply patch 127127-xx (where xx is 11 or later). • Do not apply patches 127111-02 and 127111-03. • For Solaris v10 (x64), apply patch 120665-xx (where xx is 01 or later) • For Linux, set the kernel parameters described in the following sections. Setting Linux kernel parameters To set the Linux kernel parameters: 1. Back up the kernel parameters setting files /etc/sysctl.conf and /etc/security/limits.conf. 2. Open the kernel parameters setting file /etc/sysctl.conf with a text editor and change the following settings. The parameters are specified using the syntax [name of parameter]=[value]. Four values separated by space are specified in kernel.sem. Your parameter settings must not exceed the maximum value for the operating system. The following example shows how to check whether the value is valid for kernel.shmmax: cat /proc/sys/kernel/shmmax Table 2-8 provides recommended values and calculation methods for each kernel type. Table 2-8: Kernel Type Recommended Values Parameter Name Recommended Value Calculation Method Navigator 2Database kernel.shmmax 11542528 200000000 Maximum value in current and two recommended values. kernel.shmall 22418432 22418432 Total value of current and recommended values.
2–14Preinstallation Information Hitachi Storage Navigator Modular 2 User’s Guide Open the kernel parameters setting file /etc/security/limits.conf with a text editor and change the following settings. The parameters are specified using the syntax [domain] [type] [name of parameter] [value]. Domains are specified for “*”. The types are specified for both “soft” and “hard.” The soft value must not exceed the hard value. Then, the parameter must not exceed the maximum value that the operating system specifies. Table 2-9 shows the recommended values and calculation methods for the kernel parameter types. 3. Reboot the host. Setting Solaris v8 or Solaris v9 kernel parameters When installing Navigator 2 on a management console running Solaris v8 or Solaris v9, set the Solaris kernel parameters. 1. Back up the kernel parameters setting file /etc/system. kernel.shmmni 0 2000 The larger value of: • The total value of current and Navigator 2 recommended value. •The database recommended value. kernel.threads-max 184 574 kernel.msgmni 32 32 kernel.sem (Second parameters)80 7200 kernel.sem (Forth parameters)9 1024 fs.file-max 53898 53898 Table 2-8: Kernel Type Recommended Values (Continued) Parameter Name Recommended Value Calculation Method Navigator 2Database Table 2-9: Kernel Parameter Recommended Values Parameter Name Recommended Value Calculation Method Navigator 2Database nofile 572 1344 The larger value of: • The total value of current and Navigator 2 recommended value. •The database recommended value. nproc 165 512