    							111
    Maintenance 
    Maintenance
    A lamp has finite product life. Using the lamp for long periods of time could cause the 
    pictures darker or the color tone poor. Note that each lamp has a different lifetime, and 
    some may burst or burn out soon after you start using them. 
    Preparation of a new lamp and early replacement are recommended.  To prepare a 
    new lamp, make contact with your dealer and tell the lamp type number .
    Replacing the lamp
    Type number : DT01281
    Type number : DT01291
    1.Turn the projector off, and unplug the power cord. Allow 
    the projector to cool for at least 45 minutes.
    2.Prepare a new lamp. If the projector is mounted with  
    specified mounting accessories, or if the lamp has broken, 
    also ask the dealer to replace the lamp.
    3.Loosen the screw (marked by arrow) of the lamp cover and then 
    slide down and lift the lamp cover to remove it.
    4.Loosen the 3 screws (marked by arrow) of the 
    lamp, and slowly pull the lamp out by the handles. 
    Never loosen any other screws.
    5.Insert the new lamp, and retighten firmly the 3 
    screws of the lamp that are loosened in the previous 
    process to lock it in place.
    6.While putting the interlocking parts of the lamp cover and 
    the projector together, slide the lamp cover back in place. 
    Then firmly fasten the screw of the lamp cover.
    7.Turn the projector on and reset the lamp time using the LAMP 
    TIME item in the OPTION menu.
    In case of replacement by yourself, follow the following 
    procedure. Replacing the lamp
    (4)    Point at the LAMP TIME using the ▼/▲ button, then press the ► button. A dialog will appear.
    (5)   Press the ► button to select “OK” on the dialog. It performs resetting the lamp time.
    •  Please reset the lamp time only when you have replaced the lamp, 
    for a suitable indication about the lamp. NOTE
    ►Do not touch the interior of the projector, while the lamp is 
    taken out. CAUTION
    (1) Press the MENU button to display a menu. 
    (2)  
    Point at the ADVANCED MENU in the menu using the ▼/▲ 
    button, then press the ► button.
    (3)   Point at the OPTION in the left column of the menu using the 
    ▼/▲button, then press the ► button.
    4, 5Handles
    Lamp cover
    3
    6 
    						
    							112
    Maintenance
    Lamp warning
    Replacing the lamp (continued)
     HIGH VOLTAGE  HIGH TEMPERATURE HIGH PRESSURE
    ►The projector uses a high-pressure mercury glass lamp. The lamp 
    can break with a loud bang, or burn out, if jolted or scratched, handled while hot, or 
    worn over time. Note that each lamp has a different lifetime, and some may burst or 
    burn out soon after you start using them. In addition, if the bulb bursts, it is possible 
    for shards of glass to fly into the lamp housing, and for gas containing mercury and 
    dust containing fine particles of glass to escape from the projector’s vent holes.
    ►About disposal of a lamp:  This product contains a mercury lamp; do not put 
    it in a trash. Dispose of it in accordance with environmental laws.
    •   For lamp recycling, go to  www.lamprecycle.org (in the US).
    •   For product disposal, consult your local government agency   
    or www.eiae.org  (in the US) or www.epsc.ca (in Canada).
    For more information, call your dealer. WARNING
    •  If  the  lamp  should  break  (it  will  make  a  loud  bang  when  it  does), 
    unplug  the  power  cord  from  the  outlet,  and  make  sure  to  request  a 
    replacement  lamp  from  your  local  dealer.  Note  that  shards  of  glass 
    could damage the projector’s internals, or cause injury during handling, 
    so please do not try to clean the projector or replace the lamp yourself.
    • 
    If the lamp should break (it will make a loud bang when it does), ventilate the 
    room  well,  and  make  sure  not  to  inhale  the  gas  or  fine  particles  that  come  out 
    from the projector's vent holes, and not to get them into your eyes or mouth.
    • Before replacing the lamp, turn the projector off and unplug the power 
    cord,  then  wait  at  least  45  minutes  for  the  lamp  to  cool  sufficiently. 
    Handling the lamp while hot can cause burns, as well as damaging the lamp.
    • Never unscrew except the appointed (marked by an arrow) screws.
    •  Do  not  open  the  lamp  cover  while  the  projector  is  suspended  from 
    a  ceiling.  This  is  dangerous,  since  if  the  lamp’s  bulb  has  broken,  the 
    shards  will  fall  out  when  the  cover  is  opened.  In  addition,  working  in 
    high  places  is  dangerous,  so  ask  your  local  dealer  to  have  the  lamp 
    replaced even if the bulb is not broken.
    •  Do  not  use  the  projector  with  the  lamp  cover  removed. At  the  lamp 
    replacing,  make  sure  that  the  screws  are  screwed  in  firmly.  Loose 
    screws could result in damage or injury.
    •  Use  only  the  lamp  of  the  specified  type.  Use  of  a  lamp  that  does  not 
    meet  the  lamp  specifications  for  this  model  could  cause  a  fire,  damage  or 
    shorten the life of this product.
    •  If  the  lamp  breaks  soon  after  the  first  time  it  is  used,  it  is  possible 
    that  there  are  electrical  problems  elsewhere  besides  the  lamp.  If  this 
    happens, consult your local dealer or a service representative.
    • 
    Handle with care: jolting or scratching could cause the lamp bulb to burst during use.• Using the lamp for long periods of time, could cause it dark, not to light up or to burst. 
    When  the  pictures  appear  dark,  or  when  the  color  tone  is  poor,  please  replace  the 
    lamp as soon as possible. Do not use old (used) lamps; this is a cause of breakage.
    Disconnect 
    the plug 
    from the  power outlet 
    						
    							113
    Maintenance
    Please check and clean the air filter periodically. When the indicators or a 
    message prompts you to clean the air filter, comply with it as soon as possible.
    The filter unit with 2 sheets of filters is inside of the filter cover . In addition, the 
    extra air filter is attached to inner side of the filter cover of CP-X8160 , CP-WX8255 
    and CP-WU8450 . If one of the filters is damaged or heavily soiled, replace whole 
    filter set with a new one.
    Request for a filter set with the following type number from your dealer when 
    purchasing a new one.
    Type number : MU06642
    Type number : UX38241
    1. Turn the projector off, and unplug the power cord. Allow the projector to sufficiently cool 
    down.
    2. Use a vacuum cleaner on and around the 
    filter cover.
    3. Pick and pull up the filter cover knobs to 
    take it off.
    4.  Press up slightly the bottom side knobs 
    to unlock the bottom side of the filter unit. 
    Pull the center knob to take the filter unit 
    off.
    5. Use a vacuum cleaner for the filter vent 
    of the projector and the outer side of the 
    filter unit.
    6.  The filter unit consists of two parts. Press 
    down around the interlocking parts to 
    unlock, then separate the two parts.
    7. Use a vacuum cleaner for the inner side 
    of each part of the filter unit to clean them 
    up. If the filters are damaged or heavily 
    soiled, replace them with the new ones.
    8. Combine the two parts to reassemble the 
    filter unit.
    9. Put the filter unit back into the projector.
    (continued on next page) 
    Filter cover
    Filter cover 
    knobs
    Filter unitFilter unit 
    knobs Interlocking 
    parts
    2
    3
    4, 5
    6
    7
    Extra  
    air filter
    <  Only for CP-X8160, CP-WX8240   
    and CP-WU8450>
    Cleaning and replacing the air filter 
    						
    							114
    Maintenance
    ► Before taking care of the air filter, make sure the power cable 
    is not plugged in, then allow the projector to cool sufficiently.
    ►Use only the air filter of the specified type. Do not use the projector without the 
    air filter or the filter cover. It could result in a fire or malfunction to the projector.
    ►Clean the air filter periodically. If the air filter becomes clogged by dust or the 
    like, internal temperatures rise and could cause a fire, a burn or malfunction to 
    the projector. WARNING
    • Please reset the filter time only when you have cleaned or replaced 
    the air filter, for a suitable indication about the air filter.
    • The projector may display the message such as the “CHECK THE AIR 
    FLOW” or turn off the projector, to prevent the internal heat level rising. NOTE
    Cleaning and replacing the air filter  (continued)
    10. Put the filter cover back into the place.
    11
    . Turn the projector on and reset the filter time using the FILTER TIME item 
    in the EASY MENU.
    (1)   Press the MENU button to display a menu.
    (2)   Point at the FILTER TIME using the ▲/▼ cursor buttons, then press the 
    ► cursor (or the ENTER / the  RESET) button. A dialog will appear.
    (3)   Press the ► cursor button to select the “OK” on the dialog. It performs 
    resetting the filter time. 
    						
    							115
    Maintenance
    Other care
    In order to ensure the safe use of your projector, please have it cleaned and 
    inspected by your dealer about once every year.
    1.Turn the projector off, and unplug the power cord. Allow the projector to cool 
    sufficiently.
    2.After making sure that the projector is cool adequately, lightly wipe the lens 
    with a commercially available lens-cleaning wipe. Do not touch the lens 
    directly with your hand.
    If the lens is flawed, soiled or fogged, it could cause deterioration of display 
    quality. Please take care of the lens, being cautious of handling.
    ►Before caring, make sure the power cord is not plugged in, 
    and then allow the projector to cool sufficiently. The care in a high temperature 
    state of the projector could cause a burn and/or malfunction to the projector .
    ►Never try to care for the inside of the projector personally. Doing is so 
    dangerous. 
    ►Avoid wetting the projector or inserting liquids in the projector. It could result in 
    a fire, an electric shock, and/or malfunction to the projector. 
    •   Do not put anything containing water, cleaners or chemicals near the projector. 
    •   Do not use aerosols or sprays.WARNING
    ►Please take right care of the projector according to the 
    following. Incorrect care could cause not only an injury but adverse influence 
    such as discoloration, peeling paint, etc. 
    ►Do not use cleaners or chemicals other than those specified in this manual. 
    ►Do not polish or wipe with hard objects.
    NOTICE ►Do not directly touch the lens surface with hands. CAUTION
    Inside of the projector
    Caring for the lens
    1.Turn the projector off, and unplug the power cord. Allow the projector to cool 
    sufficiently.
    2.After making sure that the projector is cool adequately, lightly wipe with gauze 
    or a soft cloth. 
    If the projector is extremely dirty, dip soft cloth in water or a neutral cleaner 
    diluted in water, and wipe lightly after wringing well. Then, wipe lightly with a 
    soft, dry cloth.
    Incorrect care could have adverse influence such as discoloration, peeling paint, 
    etc. Caring for the cabinet and remote control 
    						
    							116
    Troubleshooting
    Troubleshooting
    If an abnormal operation should occur, stop using the projector immediately.
    Otherwise if a problem occurs with the projector, the following checks and 
    measures are recommended before requesting repair. 
    If this does not resolve the problem, please contact your dealer or service 
    company. They will tell you what warranty condition is applied.
    ►Never use the projector if abnormal operations such as 
    smoke, strange odor, excessive sound, damaged casing or elements or cables, 
    penetration of liquids or foreign matter, etc. should occur. In such cases, 
    immediately disconnect the power plug from the power outlet. After making sure 
    that the smoke or odor has stopped, contact to your dealer or service company .
    WARNING
    Related messages
    When some message appears, check and cope with it according to the following 
    table. Although these messages will be automatically disappeared around several 
    minutes, it will be reappeared every time the power is turned on.
    Message
    Description
    There is no input signal.  
    Please confirm the signal input connection, and the 
    status of the signal source.
    The USB TYPE B port is selected as the picture input 
    source even if MOUSE is selected for USB TYPE B 
    (
     65).
    Select the USB DISPLAY for the USB TYPE B item in 
    the OPTION menu. In this case, you cannot use the 
    simple mouse and keyboard function. Otherwise select 
    other port for picture input.
    Projector is waiting for an image file.
    Check the hardware connection, settings on the projector 
    and network-related settings.
    The computer-Projector network connection might be 
    disconnected. Please re-connect them.
    (continued on next page)
    Troubleshooting
    Warnings displayed on the Status Monitor
    If an error occurs, a warning will be displayed on the Status Monitor  (21) . 
    Resolve the errors referring to the table of the sections "Related messages" and 
    " Regarding the indicator lamps" when the warning is displayed. 
    						
    							117
    MessageDescription
    The horizontal or vertical frequency of the input 
    signal is not within the specified range.
    Please confirm the specs for your projector or the signal 
    source specs.
    An improper signal is input. 
    Please confirm the specs for your projector or the signal 
    source specs.
    The internal temperature is rising.  
    Please turn the power off, and allow the projector to cool 
    down at least 20 minutes. After having confirmed the 
    following items, please turn the power ON again.  
     • Is there blockage of the air passage aperture?  
     • Is the air filter dirty? 
     • Does the peripheral temperature exceed 45°C?  
     •   If you use CP-X8150 , CP-WX8240, CP-SX8350 or 
    CP-WU8440 , does the peripheral temperature exceed 
    40°C?
     • Is the setting for ALTITUDE appropriate? 
    For details of ALTITUDE, refer to  ALTITUDE of 
    SERVICE in the OPTION menu (
     67). If the projector is 
    used with a wrong setting, it may cause damage to the 
    projector itself or the parts inside.
    A note of precaution when cleaning the air filter. 
    Please immediately turn the power off, and clean or 
    change the air filter referring to the  Cleaning and 
    replacing the air filter  section of this manual. After you 
    have cleaned or changed the air filter, please be sure to 
    reset the filter timer (
     65, 113).
    The button operation is not available.
    Check the button you are going to use
     (
    6). Even when 
    a usable button is pressed, all button operations are not 
    available under the following conditions.
    -   While the lens is moving, button operation from the 
    control panel or the remote control might be ignored.
    -   Pressing the one of buttons to call a signal input might 
    be ignored, when all the input ports belonging to the 
    category the button's name shows are set to the "SKIP" 
    by the item SOURCE SKIP of the OPTION menu.
    Troubleshooting
    Related messages (continued) 
    						
    							118
    Troubleshooting
    Regarding the indicator lamps
    When operation of the LAMP, TEMP and POWER indicators differs from usual, 
    check and cope with it according to the following table.
    POWER 
    indicator LAMP 
    indicator TEMP 
    indicator Description
    Lighting
    In Orange Turned
    off Turned
    off The projector is in a standby state.
    Please refer to the section “Power on/off”.
    Blinking
    In Green Turned
    off Turned
    off The projector is warming up.
    Please wait.
    Lighting
    In Green Turned
    off Turned
    off The projector is in an on state.
    Ordinary operations may be performed.
    Blinking
    In Orange Turned
    off Turned
    off The projector is cooling down.
    Please wait.
    Blinking
    In Red (discre-
    tionary) (discre-
    tionary) The projector is cooling down. A certain error 
    has been detected.Please wait until 
    POWER indicator finishes blinking, 
    and then perform the proper measure using the item 
    descriptions below.
    Blinking In Red or
    Lighting In Red Lighting
    In Red Turned
    off The lamp does not light, and there is a 
    possibility that interior portion has become 
    heated.
    Please turn the power off, and allow the projector to 
    cool down at least 20 minutes. After the projector has 
    sufficiently cooled down, please make confirmation of 
    the following items, and then turn the power on again.
    • Is there blockage of the air passage aperture?
    • Is the air filter dirty?
    • Does the peripheral temperature exceed 45°C?
     
    •   If you use CP-X8150 , CP-WX8240, CP-SX8350 
    or CP-WU8440 , does the peripheral temperature 
    exceed 40°C?
    If the same indication is displayed after the remedy, 
    please change the lamp referring to the section 
    Replacing the lamp .
    Blinking
    In Red or
    Lighting In Red Blinking
    In Red Turned
    off The lamp cover has not been properly fixed. Please turn the power off, and allow the projector to 
    cool down at least 45 minutes. After the projector has 
    sufficiently cooled down, please make confirmation 
    of the attachment state of the lamp cover. After 
    performing any needed maintenance, turn the power 
    on again. If the same indication is displayed after 
    the remedy, please contact your dealer or service 
    company.
    (continued on next page) 
    						
    							119
    Troubleshooting
    Regarding the indicator lamps (continued)
    POWER 
    indicator LAMP 
    indicator TEMP 
    indicator Description
    Blinking In Red or
    Lighting In Red Turned
    off Blinking
    In Red The cooling fan is not operating.
    Please turn the power off, and allow the projector to 
    cool down at least 20 minutes. After the projector has 
    sufficiently cooled down, please make confirmation 
    that no foreign matter has become caught in the fan, 
    etc., and then turn the power on again.
    If the same indication is displayed after the remedy, 
    please contact your dealer or service company.
    Blinking
    In Red or
    Lighting In Red Turned
    off Lighting
    In Red There is a possibility that the interior portion 
    has become heated.
    Please turn the power off, and allow the projector to 
    cool down at least 20 minutes. After the projector has 
    sufficiently cooled down, please make confirmation of 
    the following items, and then turn the power on again.
    • Is there blockage of the air passage aperture?
    • Is the air filter dirty?
    • Does the peripheral temperature exceed 45°C?
     
    •   If you use CP-X8150 , CP-WX8240, CP-SX8350 
    or CP-WU8440 , does the peripheral temperature 
    exceed 40°C?
    • Is the setting for ALTITUDE appropriate? 
    For details on ALTITUDE, refer to  ALTITUDE 
    of SERVICE in the OPTION menu (
     67). If the 
    projector is used with a wrong setting, it may cause 
    damage to the projector itself or the parts inside.
    Lighting
    In Green Simultaneous
    blinking in  RedIt is time to clean the air filter.Please immediately turn the power off, and clean or 
    change the air filter referring to the section 
    Cleaning 
    and replacing the air filter . After cleaning or 
    changing the air filter, please be sure to reset the 
    filter timer. After the remedy, reset the power to ON.
    Lighting
    In Green Alternative
    blinking in  RedThere is a possibility that the interior portion 
    has become overcooled.Please use the unit within the usage temperature 
    parameters (0°C to 40°C or 45°C (
    
    User's Manual 
    (concise))). After the treatment, reset the power to 
    ON.
    Blinking In  Green for approx. 3 seconds. Turned
    off Turned
    offAt least 1 Power ON schedule is saved to the 
    projector.
    Please refer to 3.1.7 Schedule Settings  in the 
    Network Guide.
    (continued on next page) 
    						
    							120
    • When the interior portion has become overheated, for safety 
    purposes, the projector is automatically shut down, and the indicator lamps 
    may also be turned off. In such a case, disconnect the power cord, and wait at 
    least 45 minutes. After the projector has sufficiently cooled down, please make 
    confirmation of the attachment state of the lamp and lamp cover, and then turn 
    the power on again. NOTE
    For the SECURITY indicator, see SECURITY INDICATOR in the SECURITY 
    menu (
     91) . 
    For the SHADE indicator, see the section "Temporarily shading the screen" 
    (
     36). 
    The FILTER indicator shows the condition of the air filter. Utilize this feature to 
    keep the interior of the projector in good condition.
    FILTER indicator Description
    Turned off The air filter is clean. 
     
    No need to clean up.
    Lighting In  OrangeThe air filter is going to be choked. 
     
    It is recommended to clean it.
    Lighting In  RedThe air filter is choked. 
     
    It is required to turn the power off and clean the air filter 
    immediately.
    Troubleshooting
    Regarding the indicator lamps (continued)
    Resetting all settings
    When it is hard to correct some wrong settings, the FACTORY RESET function 
    of SERVICE item in OPTION menu (
     73) can reset all settings (except settings 
    such as LANGUAGE, LAMP TIME, FILTER TIME, FILTER MESSAGE, STANDBY 
    MODE, COMMUNICATION, SECURITY and NETWORK) to the factory default.
    • The FILTER indicator might light up in orange or red when something 
    blocks the intake vents even though the air filter is clean.
    • The FILTER indicator might light up differently from other indicators or display 
    messages related to cleaning the air filter. Follow the prompt that is displayed 
    earlier. NOTE 
    						