111 Maintenance Maintenance A lamp has finite product life. Using the lamp for long periods of time could cause the pictures darker or the color tone poor. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. Preparation of a new lamp and early replacement are recommended. To prepare a new lamp, make contact with your dealer and tell the lamp type number . Replacing the lamp Type number : DT01281 Type number : DT01291 1.Turn the projector off, and unplug the power cord. Allow the projector to cool for at least 45 minutes. 2.Prepare a new lamp. If the projector is mounted with specified mounting accessories, or if the lamp has broken, also ask the dealer to replace the lamp. 3.Loosen the screw (marked by arrow) of the lamp cover and then slide down and lift the lamp cover to remove it. 4.Loosen the 3 screws (marked by arrow) of the lamp, and slowly pull the lamp out by the handles. Never loosen any other screws. 5.Insert the new lamp, and retighten firmly the 3 screws of the lamp that are loosened in the previous process to lock it in place. 6.While putting the interlocking parts of the lamp cover and the projector together, slide the lamp cover back in place. Then firmly fasten the screw of the lamp cover. 7.Turn the projector on and reset the lamp time using the LAMP TIME item in the OPTION menu. In case of replacement by yourself, follow the following procedure. Replacing the lamp (4) Point at the LAMP TIME using the ▼/▲ button, then press the ► button. A dialog will appear. (5) Press the ► button to select “OK” on the dialog. It performs resetting the lamp time. • Please reset the lamp time only when you have replaced the lamp, for a suitable indication about the lamp. NOTE ►Do not touch the interior of the projector, while the lamp is taken out. CAUTION (1) Press the MENU button to display a menu. (2) Point at the ADVANCED MENU in the menu using the ▼/▲ button, then press the ► button. (3) Point at the OPTION in the left column of the menu using the ▼/▲button, then press the ► button. 4, 5Handles Lamp cover 3 6
112 Maintenance Lamp warning Replacing the lamp (continued) HIGH VOLTAGE HIGH TEMPERATURE HIGH PRESSURE ►The projector uses a high-pressure mercury glass lamp. The lamp can break with a loud bang, or burn out, if jolted or scratched, handled while hot, or worn over time. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. In addition, if the bulb bursts, it is possible for shards of glass to fly into the lamp housing, and for gas containing mercury and dust containing fine particles of glass to escape from the projector’s vent holes. ►About disposal of a lamp: This product contains a mercury lamp; do not put it in a trash. Dispose of it in accordance with environmental laws. • For lamp recycling, go to www.lamprecycle.org (in the US). • For product disposal, consult your local government agency or www.eiae.org (in the US) or www.epsc.ca (in Canada). For more information, call your dealer. WARNING • If the lamp should break (it will make a loud bang when it does), unplug the power cord from the outlet, and make sure to request a replacement lamp from your local dealer. Note that shards of glass could damage the projector’s internals, or cause injury during handling, so please do not try to clean the projector or replace the lamp yourself. • If the lamp should break (it will make a loud bang when it does), ventilate the room well, and make sure not to inhale the gas or fine particles that come out from the projector's vent holes, and not to get them into your eyes or mouth. • Before replacing the lamp, turn the projector off and unplug the power cord, then wait at least 45 minutes for the lamp to cool sufficiently. Handling the lamp while hot can cause burns, as well as damaging the lamp. • Never unscrew except the appointed (marked by an arrow) screws. • Do not open the lamp cover while the projector is suspended from a ceiling. This is dangerous, since if the lamp’s bulb has broken, the shards will fall out when the cover is opened. In addition, working in high places is dangerous, so ask your local dealer to have the lamp replaced even if the bulb is not broken. • Do not use the projector with the lamp cover removed. At the lamp replacing, make sure that the screws are screwed in firmly. Loose screws could result in damage or injury. • Use only the lamp of the specified type. Use of a lamp that does not meet the lamp specifications for this model could cause a fire, damage or shorten the life of this product. • If the lamp breaks soon after the first time it is used, it is possible that there are electrical problems elsewhere besides the lamp. If this happens, consult your local dealer or a service representative. • Handle with care: jolting or scratching could cause the lamp bulb to burst during use.• Using the lamp for long periods of time, could cause it dark, not to light up or to burst. When the pictures appear dark, or when the color tone is poor, please replace the lamp as soon as possible. Do not use old (used) lamps; this is a cause of breakage. Disconnect the plug from the power outlet
113 Maintenance Please check and clean the air filter periodically. When the indicators or a message prompts you to clean the air filter, comply with it as soon as possible. The filter unit with 2 sheets of filters is inside of the filter cover . In addition, the extra air filter is attached to inner side of the filter cover of CP-X8160 , CP-WX8255 and CP-WU8450 . If one of the filters is damaged or heavily soiled, replace whole filter set with a new one. Request for a filter set with the following type number from your dealer when purchasing a new one. Type number : MU06642 Type number : UX38241 1. Turn the projector off, and unplug the power cord. Allow the projector to sufficiently cool down. 2. Use a vacuum cleaner on and around the filter cover. 3. Pick and pull up the filter cover knobs to take it off. 4. Press up slightly the bottom side knobs to unlock the bottom side of the filter unit. Pull the center knob to take the filter unit off. 5. Use a vacuum cleaner for the filter vent of the projector and the outer side of the filter unit. 6. The filter unit consists of two parts. Press down around the interlocking parts to unlock, then separate the two parts. 7. Use a vacuum cleaner for the inner side of each part of the filter unit to clean them up. If the filters are damaged or heavily soiled, replace them with the new ones. 8. Combine the two parts to reassemble the filter unit. 9. Put the filter unit back into the projector. (continued on next page) Filter cover Filter cover knobs Filter unitFilter unit knobs Interlocking parts 2 3 4, 5 6 7 Extra air filter < Only for CP-X8160, CP-WX8240 and CP-WU8450> Cleaning and replacing the air filter
114 Maintenance ► Before taking care of the air filter, make sure the power cable is not plugged in, then allow the projector to cool sufficiently. ►Use only the air filter of the specified type. Do not use the projector without the air filter or the filter cover. It could result in a fire or malfunction to the projector. ►Clean the air filter periodically. If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn or malfunction to the projector. WARNING • Please reset the filter time only when you have cleaned or replaced the air filter, for a suitable indication about the air filter. • The projector may display the message such as the “CHECK THE AIR FLOW” or turn off the projector, to prevent the internal heat level rising. NOTE Cleaning and replacing the air filter (continued) 10. Put the filter cover back into the place. 11 . Turn the projector on and reset the filter time using the FILTER TIME item in the EASY MENU. (1) Press the MENU button to display a menu. (2) Point at the FILTER TIME using the ▲/▼ cursor buttons, then press the ► cursor (or the ENTER / the RESET) button. A dialog will appear. (3) Press the ► cursor button to select the “OK” on the dialog. It performs resetting the filter time.
115 Maintenance Other care In order to ensure the safe use of your projector, please have it cleaned and inspected by your dealer about once every year. 1.Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. 2.After making sure that the projector is cool adequately, lightly wipe the lens with a commercially available lens-cleaning wipe. Do not touch the lens directly with your hand. If the lens is flawed, soiled or fogged, it could cause deterioration of display quality. Please take care of the lens, being cautious of handling. ►Before caring, make sure the power cord is not plugged in, and then allow the projector to cool sufficiently. The care in a high temperature state of the projector could cause a burn and/or malfunction to the projector . ►Never try to care for the inside of the projector personally. Doing is so dangerous. ►Avoid wetting the projector or inserting liquids in the projector. It could result in a fire, an electric shock, and/or malfunction to the projector. • Do not put anything containing water, cleaners or chemicals near the projector. • Do not use aerosols or sprays.WARNING ►Please take right care of the projector according to the following. Incorrect care could cause not only an injury but adverse influence such as discoloration, peeling paint, etc. ►Do not use cleaners or chemicals other than those specified in this manual. ►Do not polish or wipe with hard objects. NOTICE ►Do not directly touch the lens surface with hands. CAUTION Inside of the projector Caring for the lens 1.Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. 2.After making sure that the projector is cool adequately, lightly wipe with gauze or a soft cloth. If the projector is extremely dirty, dip soft cloth in water or a neutral cleaner diluted in water, and wipe lightly after wringing well. Then, wipe lightly with a soft, dry cloth. Incorrect care could have adverse influence such as discoloration, peeling paint, etc. Caring for the cabinet and remote control
116 Troubleshooting Troubleshooting If an abnormal operation should occur, stop using the projector immediately. Otherwise if a problem occurs with the projector, the following checks and measures are recommended before requesting repair. If this does not resolve the problem, please contact your dealer or service company. They will tell you what warranty condition is applied. ►Never use the projector if abnormal operations such as smoke, strange odor, excessive sound, damaged casing or elements or cables, penetration of liquids or foreign matter, etc. should occur. In such cases, immediately disconnect the power plug from the power outlet. After making sure that the smoke or odor has stopped, contact to your dealer or service company . WARNING Related messages When some message appears, check and cope with it according to the following table. Although these messages will be automatically disappeared around several minutes, it will be reappeared every time the power is turned on. Message Description There is no input signal. Please confirm the signal input connection, and the status of the signal source. The USB TYPE B port is selected as the picture input source even if MOUSE is selected for USB TYPE B ( 65). Select the USB DISPLAY for the USB TYPE B item in the OPTION menu. In this case, you cannot use the simple mouse and keyboard function. Otherwise select other port for picture input. Projector is waiting for an image file. Check the hardware connection, settings on the projector and network-related settings. The computer-Projector network connection might be disconnected. Please re-connect them. (continued on next page) Troubleshooting Warnings displayed on the Status Monitor If an error occurs, a warning will be displayed on the Status Monitor (21) . Resolve the errors referring to the table of the sections "Related messages" and " Regarding the indicator lamps" when the warning is displayed.
117 MessageDescription The horizontal or vertical frequency of the input signal is not within the specified range. Please confirm the specs for your projector or the signal source specs. An improper signal is input. Please confirm the specs for your projector or the signal source specs. The internal temperature is rising. Please turn the power off, and allow the projector to cool down at least 20 minutes. After having confirmed the following items, please turn the power ON again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 45°C? • If you use CP-X8150 , CP-WX8240, CP-SX8350 or CP-WU8440 , does the peripheral temperature exceed 40°C? • Is the setting for ALTITUDE appropriate? For details of ALTITUDE, refer to ALTITUDE of SERVICE in the OPTION menu ( 67). If the projector is used with a wrong setting, it may cause damage to the projector itself or the parts inside. A note of precaution when cleaning the air filter. Please immediately turn the power off, and clean or change the air filter referring to the Cleaning and replacing the air filter section of this manual. After you have cleaned or changed the air filter, please be sure to reset the filter timer ( 65, 113). The button operation is not available. Check the button you are going to use ( 6). Even when a usable button is pressed, all button operations are not available under the following conditions. - While the lens is moving, button operation from the control panel or the remote control might be ignored. - Pressing the one of buttons to call a signal input might be ignored, when all the input ports belonging to the category the button's name shows are set to the "SKIP" by the item SOURCE SKIP of the OPTION menu. Troubleshooting Related messages (continued)
118 Troubleshooting Regarding the indicator lamps When operation of the LAMP, TEMP and POWER indicators differs from usual, check and cope with it according to the following table. POWER indicator LAMP indicator TEMP indicator Description Lighting In Orange Turned off Turned off The projector is in a standby state. Please refer to the section “Power on/off”. Blinking In Green Turned off Turned off The projector is warming up. Please wait. Lighting In Green Turned off Turned off The projector is in an on state. Ordinary operations may be performed. Blinking In Orange Turned off Turned off The projector is cooling down. Please wait. Blinking In Red (discre- tionary) (discre- tionary) The projector is cooling down. A certain error has been detected.Please wait until POWER indicator finishes blinking, and then perform the proper measure using the item descriptions below. Blinking In Red or Lighting In Red Lighting In Red Turned off The lamp does not light, and there is a possibility that interior portion has become heated. Please turn the power off, and allow the projector to cool down at least 20 minutes. After the projector has sufficiently cooled down, please make confirmation of the following items, and then turn the power on again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 45°C? • If you use CP-X8150 , CP-WX8240, CP-SX8350 or CP-WU8440 , does the peripheral temperature exceed 40°C? If the same indication is displayed after the remedy, please change the lamp referring to the section Replacing the lamp . Blinking In Red or Lighting In Red Blinking In Red Turned off The lamp cover has not been properly fixed. Please turn the power off, and allow the projector to cool down at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp cover. After performing any needed maintenance, turn the power on again. If the same indication is displayed after the remedy, please contact your dealer or service company. (continued on next page)
119 Troubleshooting Regarding the indicator lamps (continued) POWER indicator LAMP indicator TEMP indicator Description Blinking In Red or Lighting In Red Turned off Blinking In Red The cooling fan is not operating. Please turn the power off, and allow the projector to cool down at least 20 minutes. After the projector has sufficiently cooled down, please make confirmation that no foreign matter has become caught in the fan, etc., and then turn the power on again. If the same indication is displayed after the remedy, please contact your dealer or service company. Blinking In Red or Lighting In Red Turned off Lighting In Red There is a possibility that the interior portion has become heated. Please turn the power off, and allow the projector to cool down at least 20 minutes. After the projector has sufficiently cooled down, please make confirmation of the following items, and then turn the power on again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 45°C? • If you use CP-X8150 , CP-WX8240, CP-SX8350 or CP-WU8440 , does the peripheral temperature exceed 40°C? • Is the setting for ALTITUDE appropriate? For details on ALTITUDE, refer to ALTITUDE of SERVICE in the OPTION menu ( 67). If the projector is used with a wrong setting, it may cause damage to the projector itself or the parts inside. Lighting In Green Simultaneous blinking in RedIt is time to clean the air filter.Please immediately turn the power off, and clean or change the air filter referring to the section Cleaning and replacing the air filter . After cleaning or changing the air filter, please be sure to reset the filter timer. After the remedy, reset the power to ON. Lighting In Green Alternative blinking in RedThere is a possibility that the interior portion has become overcooled.Please use the unit within the usage temperature parameters (0°C to 40°C or 45°C ( User's Manual (concise))). After the treatment, reset the power to ON. Blinking In Green for approx. 3 seconds. Turned off Turned offAt least 1 Power ON schedule is saved to the projector. Please refer to 3.1.7 Schedule Settings in the Network Guide. (continued on next page)
120 • When the interior portion has become overheated, for safety purposes, the projector is automatically shut down, and the indicator lamps may also be turned off. In such a case, disconnect the power cord, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again. NOTE For the SECURITY indicator, see SECURITY INDICATOR in the SECURITY menu ( 91) . For the SHADE indicator, see the section "Temporarily shading the screen" ( 36). The FILTER indicator shows the condition of the air filter. Utilize this feature to keep the interior of the projector in good condition. FILTER indicator Description Turned off The air filter is clean. No need to clean up. Lighting In OrangeThe air filter is going to be choked. It is recommended to clean it. Lighting In RedThe air filter is choked. It is required to turn the power off and clean the air filter immediately. Troubleshooting Regarding the indicator lamps (continued) Resetting all settings When it is hard to correct some wrong settings, the FACTORY RESET function of SERVICE item in OPTION menu ( 73) can reset all settings (except settings such as LANGUAGE, LAMP TIME, FILTER TIME, FILTER MESSAGE, STANDBY MODE, COMMUNICATION, SECURITY and NETWORK) to the factory default. • The FILTER indicator might light up in orange or red when something blocks the intake vents even though the air filter is clean. • The FILTER indicator might light up differently from other indicators or display messages related to cleaning the air filter. Follow the prompt that is displayed earlier. NOTE