Page 11
Command Control via the Network (continued) Command Format [TCP #23] 1. Protocol Consist of header (7 bytes) + command data (6 bytes) 2. Header BE + EF + 03 + 06 + 00 + CRC_low + CRC_high CRC_low: Lower byte of CRC flag for command data CRC_high: Upper byte of CRC flag for command data 3. Command data Command data chart byte_0byte_byte_2byte_3byte_4byte_5 ActionTypeSetting code lowhighlowhighlowhigh Action (byte_0 - ) ActionClassificationContent SetChange setting to desired...
Page 12
2 Command Control via the Network (continued) Decreasing the projector setting value (Decrement command) () The PC sends the following decrement code to the projector. Header + Command data (‘05H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’) (2) The projector decreases the setting value on the above setting code. (3) The projector returns the response code ‘06H’ to the PC. When the projector cannot understand the received command When the projector cannot understand the received command, the...
Page 13
3 Command Control via the Network (continued) 7. Reply Data The connection ID (the data is same as the connection ID data on the sending data format) is attached to the Network control commands reply data. ACK reply: ‘06H’ + ‘xxH’ NAK reply: ‘15H’ + ‘xxH’ Error reply: ‘1CH’ + ‘xxxxH’ + ‘xxH’ Data reply: ‘1DH’ + ‘xxxxH’ + ‘xxH’ Projector busy reply: ‘1FH’ + ‘xxxxH’ + ‘xxH’ Authentication error reply: ‘1FH’ + ‘0400H’ + ‘xxH’ (‘xxH’ : connection ID) Automatic Connection Break...
Page 14
4 Names Operation TypeHeader Command DataCRCActionType Setting Code PowerSet Turn off BE EF0306 00 2A D3 01 00 00 60 00 00 Turn on BE EF0306 00 BA D2 01 00 00 60 01 00Get BE EF0306 00 19 D3 02 0000 60 00 00[Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input SourceSetCOMPUTER1 BE EF0306 00 FE D2 01 0000 20 00 00COMPUTER2 BE EF0306 00 3E D0 01 0000 20 04 00HDMI BE EF0306 00 0E D2 01 0000 20 03 00COMPONENT BE EF0306 00 AE D1 01 0000 20...
Page 15
5 RS-232C communication / Network command table (continued) Names Operation TypeHeader Command DataCRCActionType Setting Code User Gamma PatternSetOff BE EF0306 00 FB FA 01 0080 30 00 00 9 steps gray scale BE EF0306 00 6B FB 01 0080 30 01 00 15 steps gray scale BE EF0306 00 9B FB 01 0080 30 02 00Ramp BE EF0306 00 0B FA 01 0080 30 03 00Get BE EF0306 00 C8 FA 02 0080 30 00 00 User Gamma Point 1Get BE EF0306 00 08 FE 02 0090 30 00 00Increment BE EF0306 00 6E FE...
Page 16
6 Names Operation TypeHeader Command DataCRCActionType Setting Code COLOR TEMP GAIN BGet BE EF0306 00 8C F5 02 00B3 30 00 00Increment BE EF0306 00 EA F5 04 00 B3 30 00 00Decrement BE EF0306 00 3B F4 05 00B3 30 00 00 COLOR TEMP OFFSET RGet BE EF0306 00 04 F5 02 00B5 30 00 00Increment BE EF0306 00 62 F5 04 00B5 30 00 00Decrement BE EF0306 00 B3 F4 05 00B5 30 00 00 COLOR TEMP OFFSET GGet BE EF0306 00 40 F5 02 00B6 30 00 00Increment BE EF0306 00 26 F5...
Page 17
7 Names Operation TypeHeader Command DataCRCActionType Setting Code OVER SCANGet BE EF0306 00 91 7002 0009 22 00 00Increment BE EF0306 00 F7 70 04 0009 22 00 00Decrement BE EF0306 00 26 7105 0009 22 00 00 OVER SCAN ResetExecute BE EF0306 00 EC D9 06 0027 70 00 00 V POSITIONGet BE EF0306 00 0D 83 02 0000 21 00 00Increment BE EF0306 00 6B 83 04 0000 21 00 00Decrement BE EF0306 00 BA 82 05 00 00 21 00 00 V POSITION ResetExecute BE EF0306 00 E0 D2 06 0002...
Page 18
8 NamesOperation TypeHeader Command DataCRCActionType Setting Code FRAME LOCK – COMPUTER1Set TURN OFF BE EF0306 00 3B C2 01 0050 30 00 00 TURN ON BE EF0306 00 AB C3 01 0050 30 01 00Get BE EF0306 00 08 C2 02 0050 30 00 00 FRAME LOCK – COMPUTER2Set TURN OFF BE EF0306 00 0B C3 01 0054 30 00 00 TURN ON BE EF0306 00 9B C2 01 0054 30 01 00Get BE EF0306 00 38 C3 02 0054 30 00 00 FRAME LOCK - HDMISet TURN OFF BE EF0306 00 7F C2 01 0053 30 00 00 TURN ON BE...
Page 19
9 Names Operation TypeHeader Command DataCRCActionType Setting Code VOLUME-VideoGet BE EF0306 00 31 CD 02 0061 20 00 00Increment BE EF0306 00 57 CD 04 0061 20 00 00Decrement BE EF0306 00 86 CC 05 0061 20 00 00 VOLUME – MIUGet BE EF0306 00 45 CC 02 0066 20 00 00Increment BE EF0306 00 23 CC 04 0066 20 00 00Decrement BE EF0306 00 F2 CD 05 0066 20 00 00MUTESetTURN OFF BE EF0306 00 46 D3 01 0002 20 00 00 TURN ON BE EF0306 00 D6 D2 01 0002 20 01 00Get BE...
Page 20
20 Names Operation TypeHeader Command DataCRCActionType Setting Code HDMI-AUDIOSet1 BE EF0306 00 AE C6 01 0040 20 01 002 BE EF0306 00 5E C6 01 0040 20 02 00Get BE EF0306 00 0D C7 02 0040 20 00 00 REMOTE FREQ. NORMALSetOff BE EF0306 00 FF 3D 01 0030 26 00 00On BE EF0306 00 6F 3C 01 0030 26 01 00Get BE EF0306 00 CC 3D 02 0030 26 00 00 REMOTE FREQ. HIGHSetOff BE EF0306 00 03 3C 01 0031 26 00 00On BE EF0306 00 93 3D 01 0031 26 01 00Get BE EF0306 00 30 3C 02...