Page 81
4 DS-VIDEO Mini DIN 4pin jack • System: NTSC, PAL, SECAM, PAL-M, PAL-N, NTSC4.43, PAL (60Hz) PinSignal 1Color signal 0.286Vp-p (NTSC, burst), 75Ω terminator Color signal 0.300Vp-p (PAL/SECAM, burst) 75Ω terminator 2Brightness signal, 1.0Vp-p, 75Ω terminator 3 Ground 4 Ground Connection to the ports (continued) 4 3 21 EVIDEO RCA jack • System: NTSC, PAL, SECAM, PAL-M, PAL-N, NTSC4.43, PAL (60Hz) • 1.0±0.1Vp-p, 75Ω terminator E D
Page 82
5 Connection to the ports (continued) FAUDIO IN1, GAUDIO IN2 Ø3.5 stereo mini jack • 200 mVrms 47kΩ terminator HAUDIO OUT Ø3.5 stereo mini jack • 200 mVrms 1kΩ output impedance GH F
Page 83
6 Connection to the ports (continued) IUSB USB B type jack PinSignal 1 +5V 2- Data 3+ Data 4 Ground43 12 JCONTROL D-sub 9pin plug • About the details of RS-232C communication, please refer to the following page. PinSignalPinSignalPinSignal 1(No connection)4(No connection)7RTS 2RD5 Ground 8CTS 3TD6(No connection)9(No connection) J I 6 5432198 7
Page 84
7 To input component video signal to COMPUTER IN ports ex. Y CB/PB CR/PRCOMPONENT VIDEO OUT Connection to the ports (continued) To input component video signal to the COMPUTER IN1 or IN2 port of the projector, use a RCA to D-sub cable or adapter. For about the pin description of the required cable or adapter, refer to the descriptions about COMPUTER IN1 and IN2 port ( 3). RCA plugs D-sub plug VCR/DVD/Blu-ray Disc player RCA connectors
Page 85
8 RS-232C Communication RS-232C Communication When the projector connects to the computer by RS-232C communication, the projector can be controlled with RS-232C commands from the computer. For details of RS-232C commands, refer to RS-232C Communication command table ( 10). Connection 1.Turn off the projector and the computer. 2.Connect the projectors CONTROL port and the computers RS-232C port with a RS-232C cable (cross). Use the cable that ful lls the speci cation shown in gure. 3.Turn the...
Page 86
9 RS-232C Communication (continued) Communication settings 1. Protocol 19200bps,8N1 2. Command format(h shows hexadecimal) Byte Number 01 2 3456789101112 Command ActionHeaderData Header code Packet Data sizeCRC agActionTy p eSetting code LHLHLHLHLHLH Change setting to desired value [(cL)(cH)] by [(eL)(eH)]. BEh EFh 03h 06h 00h(aL)(aH)01h 00h (bL)(bH)(cL)(cH) Read projector internal setup value [(bL) (bH)] .(aL)(aH)02h 00h (bL)(bH)00h 00h Increment setup value [(bL)(bH)] by 1.(aL)(aH)04h 00h...
Page 87
10 Names Operation Type HeaderCommand Data CRC Action Type Setting Code Power Set Turn off BE EF 03 06 00 2A D3 01 00 00 60 00 00 Turn on BE EF 03 06 00 BA D2 01 00 00 60 01 00 Get BE EF 03 06 00 19 D3 02 00 00 60 00 00 [Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input Source Set COMPUTER IN1 BE EF 03 06 00 FE D2 01 00 00 20 00 00 COMPUTER IN2 BE EF 03 06 00 3E D0 01 00 00 20 04 00 S-VIDEO BE EF 03 06 00 9E D3 01 00 00 20 02 00 VIDEO BE EF 03 06 00...
Page 88
11 Names Operation Type HeaderCommand Data CRC Action Type Setting Code GAMMA Set DEFAULT-1 BE EF 03 06 00 07 E9 01 00 A1 30 20 00 CUSTOM-1 BE EF 03 06 00 07 FD 01 00 A1 30 10 00 DEFAULT-2 BE EF 03 06 00 97 E8 01 00 A1 30 21 00 CUSTOM-2 BE EF 03 06 00 97 FC 01 00 A1 30 11 00 DEFAULT-3 BE EF 03 06 00 67 E8 01 00 A1 30 22 00 CUSTOM-3 BE EF 03 06 00 67 FC 01 00 A1 30 12 00 DEFAULT-4 BE EF 03 06 00 F7 E9 01 00 A1 30 23 00 CUSTOM-4 BE EF 03 06 00 F7 FD 01 00 A1...
Page 89
12 Names Operation Type HeaderCommand Data CRC Action Type Setting Code User Gamma Point 8 Get BE EF 03 06 00 7C FF 02 00 97 30 00 00 Increment BE EF 03 06 00 1A FF 04 00 97 30 00 00 Decrement BE EF 03 06 00 CB FE 05 00 97 30 00 00 User Gamma Point 8 ResetExecute BE EF 03 06 00 2C C3 06 00 57 70 00 00 COLOR TEMP Set 1 HIGH BE EF 03 06 00 0B F5 01 00 B0 30 03 00 1 CUSTOM BE EF 03 06 00 CB F8 01 00 B0 30 13 00 2 MID BE EF 03 06 00 9B F4 01 00 B0 30 02 00 2 CUSTOM...
Page 90
13 Names Operation Type HeaderCommand Data CRC Action Type Setting Code COLOR Get BE EF 03 06 00 B5 72 02 00 02 22 00 00 Increment BE EF 03 06 00 D3 72 04 00 02 22 00 00 Decrement BE EF 03 06 00 02 73 05 00 02 22 00 00 COLOR Reset Execute BE EF 03 06 00 80 D0 06 00 0A 70 00 00 TINT Get BE EF 03 06 00 49 73 02 00 03 22 00 00 Increment BE EF 03 06 00 2F 73 04 00 03 22 00 00 Decrement BE EF 03 06 00 FE 72 05 00 03 22 00 00 TINT Reset Execute BE EF 03 06 00 7C D1...