432-0005-00-12 Rev 100 — Voyager III Installation Guide 9 Physical Installation Voyager III Bulkhead Box • Provide room for adequate service loops as depicted in the installation drawings supplied. • Using customer-supplied hardware, moun t the Voyager III bulkhead box. Refer to the bulkhead box drawings in the Voyager III ICD for detailed instructions. 203.20 mm (8.00 in.) 203.20 mm (8.00 in.) 174.61 mm (6.87 in.) 110.49 mm Recommended (4.35 in.) 323.85 mm (12.75 in.) 8X 7.92 mm (0.31 in.) Bulkhead...
Page 12
Physical Installation 10432-0005-00-12 Rev 100 — Voyager III Installation Guide Voyager III Joystick Control Unit (JCU) The cable gland seal is designed for use with double-shielded category 5 Ethernet cable. To ensure a good seal and to maintain compliance with EMI ratings, a double-shielded cable is required. The JCU enclosure is rated IP66 above the JCU mounting surface/gasket and rated IP64 behind or below the gasket. Caution : An installation template is provided in the JCU ICD (Doc. #...
Page 13
432-0005-00-12 Rev 100 — Voyager III Installation Guide 11 Electrical Connections If you intend to mount the JCU to a panel of 0.31 inches (0.79 cm) thickness or less, remove the clamps from the mounting screws, turn them around and thread them back onto each of the four screws. In this configuration, the clamp foot faces the rear of the mounting surface and a llows the clamp to contact thinner panel surfaces while still allowing for proper co mpression of the JCU mounting gasket to form a...
Page 14
Electrical Connections 12432-0005-00-12 Rev 100 — Voyager III Installation Guide Proper Grounding Caution: Ensure the Voyager III system is properly grounded. The camera body and bulkhead box chassis grounding studs are provided for implementing the grounding scheme applicable to the vessel. Caution: If multiple analog video displays are installed, to minimize ground loops FLIR recommends using a video distribution panel for each video channel (primary and secondary) specific to the installation...
Page 15
432-0005-00-12 Rev 100 — Voyager III Installation Guide 13 Electrical Connections • Channel locks • 2 mm flathead screw driver Install the Main Sensor Cable Gland Seal Step 1.Remove the main sensor cable feed-through gland seal (A) by unscrewing the lock nut (B) on the inside of the bulkhead box. Step 2.Unscrew the squeeze nut (C) from the gland body (D), as shown above, to expose the gland barrel (E). Step 3.Remove the gland barrel from the gland body by inserting a finger and pulling it out. Step...
Page 16
Electrical Connections 14432-0005-00-12 Rev 100 — Voyager III Installation Guide Step 6.Measure a minimum of 15.75 in. (40 cm) from the end of the cable, carefully cut around the outer black cable jacket until you can slide it off, and remove it. Be careful not to cut into the metal braid beneath the outer jacket. Step 7.Slide the black outer jacket off the c able, exposing the inner metal braid. Step 8.Push the braid back over the black outer jacket an inch or two, creating an area of slack in the...
Page 17
432-0005-00-12 Rev 100 — Voyager III Installation Guide 15 Electrical Connections Step 14.Slide the gland body over the gland barrel; capturing the metal braid between the two. Step 15.Screw and tighten the squeeze nut onto the gland body as shown. You are now ready to prepare the cable ends for connection to the bulkhead box’s internal terminal blocks and connectors. Refer to the Voyager III bulkhead box description in the ICD. Note: All trim lengths are terminated wire lengths—the wire and the...
Page 18
Electrical Connections 16432-0005-00-12 Rev 100 — Voyager III Installation Guide Step 7.The wires for J5 and J6 will need to be prepared in a fashion similar to the following progression. Carefully meas ure, cut, and strip each wire as described in the Voyager III bulkhead box description in the ICD. Slide the outer insulation off. Separate the inner wires. When this is done, they are ready for termination to the terminal block plugs for J5 and J6. Note: You can terminate the wires at J5 and J6...
Page 19
432-0005-00-12 Rev 100 — Voyager III Installation Guide 17 Electrical Connections Step 8.The finished cable, shown below, has the RJ45 connector, two BNC video connectors, and all other leads termi nated at the terminal block plugs. Step 9.Carefully slide all of the prepared wires and the video cables through the hole in the bulkhead box. Step 10.Slide the locknut over the wires and tighten to secure the cable gland seal to the bulkhead box. Step 11.If you have not done so already, connect the...
Page 20
Electrical Connections 18432-0005-00-12 Rev 100 — Voyager III Installation Guide Note:Use the Video Tracker PCB, PN 250-0404-00, at connector J7 if the Video Tracker module is removed from the bulkhead box for service or repair and you want to continue using the camera system without it. The PCB is provided in a separate bag in the bulkhead box.