Page 31
432-0010-00-12 Rev 100 — MD-Series Installation Guide 29 Installing MD-Series Systems The JCU enclosure is rated IP66 above the JCU mounting surface/gasket and rated IP64 behind or below the gasket. Caution : An installation template is provided in the JCU ICD. If the template is printed from the PDF file, ensure it is pr inted to the correct scale by checking the dimensions prior to cutting any holes. 1.Using the JCU template su pplied as a guide in MD-Series ICD, mark the location of the...
Page 32
Installing MD-Series Systems 30432-0010-00-12 Rev 100 — MD-Series Installation Guide allowing for proper compression of the JCU mounting gasket to form a watertight seal.
Page 33
432-0010-00-12 Rev 100 MD-Series Installation Guide 33 CHAPTER 2MD-Series Reference Introduction This chapter includes the following reference information: • A summary of maintenance procedures • A table of camera specifications • Information about standards referenced during the installation procedure • A glossary of acronyms • A table comparing features of various MD-Series models MD-Series Maintenance The MD-Series components are designed for years of rugged, trouble-free use. Cleaning the Camera...
Page 34
MD-Series Reference 34432-0010-00-12 Rev 100 — MD-Series Installation Guide window requires further cleaning, use a soft moist cotton-based cloth with isopropyl alcohol or dish soap. Do not use abrasive materials, such as paper or scrub brushes as this will possibly damage the lens by scratching it. Only wipe the lens clean when you can visually see contamination on the surface. Cleaning the Camera Body Do not use a pressure washer to clean the camera, as that could force water through the camera...
Page 35
432-0010-00-12 Rev 100 — MD-Series Installation Guide 35 MD-Series Reference MD-Series Specifications Table 2.1 lists details about physical characteristics, power usage, and environmental features of the MD-Series camera. Table 2.1 Specifications Physical Characteristics Camera Size 5.2 cm (6 in) di ameter, 17.8 cm (7 in) tall Camera Weight Under 1.4 kg (3 lb), depending on the camera model Joystick Size 9.1 X 14.2 X 8.13 cm (3.6 X 5.6 X 3.2 in) 3.17 cm (1.25 in) above platform including joystick...
Page 36
MD-Series Reference 36432-0010-00-12 Rev 100 — MD-Series Installation Guide External Standards Table 2.2 lists other sources of information and standards definitions that may be useful during the installation of the MD-Series camera. Table 2.2 External References Standard Description ANSI/SCTE 01 2006 “F” Port, Female, Outdoor http://www.scte.org IEC 60169-24 Radio-frequency coaxial connectors with screw coupling, typically for use in 75 Ohm cable distribution systems (Type F) IEC 60945...
Page 37
432-0010-00-12 Rev 100 — MD-Series Installation Guide 37 MD-Series Reference Acronyms Table 2.3 lists each acronym that is used in this manual and its meaning. Table 2.3 Acronyms Acronym/Term Definition AGC Automatic Gain Control ANSI American National Standards Institute EAR Export Administra tion Regulations EMI Electromagnetic Interference FFC Flat Field Correction FLIR Forward Looking Infrared FoV Field of View FPS Frames per Second (refresh rate) HFoV Horizontal Field of View ICD Interface...
Page 38
MD-Series Reference 38432-0010-00-12 Rev 100 — MD-Series Installation Guide Feature Comparison of MD-Series Models Table 2.4 lists the two MD-Series models and supported features. Each model is available in four variations, identified by a unique part number: •
Page 39
432-0010-00-12 Rev 100 — MD-Series Installation Guide 39 MD-Series Reference Troubleshooting Tips This section includes information that may help you with common issues that may arise during operation of the MD-Series system. Video not displayed on monitor If the camera will not produce an image, check the video connection at the camera and at the display. If the connectors appear to be properly connected but the camera still does not produce an image, ensure that power has been properly applied to...
Page 40
MD-Series Reference 40432-0010-00-12 Rev 100 — MD-Series Installation Guide Check cable connector terminations. Inferior quality connections may use multiple adapters that can cause unacceptable noise. Image too dark or too light By default, the MD-Series thermal camera uses an automatic gain control (AGC) setting that has proven to be superior for most applications. However, a specific environment may benefit from a different AG C setting. For example, a very cold background (such as the sky)...