432-0010-00-12 Rev 100 — MD-Series Installation Guide 29
 Installing MD-Series Systems
The JCU enclosure is rated IP66 above the JCU mounting surface/gasket and 
rated IP64 behind or below the gasket.
Caution : An installation template is provided  in the JCU ICD. If the template is 
printed from the PDF file, ensure it is pr inted to the correct scale by checking the 
dimensions prior to cutting any holes.
1.Using the JCU template su pplied as a guide in MD-Series ICD, mark the 
location of the...

Page 32

 Installing MD-Series Systems
30432-0010-00-12 Rev 100 — MD-Series Installation Guide 
allowing for proper compression of the JCU mounting gasket to form a watertight 
seal. 

Page 33

432-0010-00-12 Rev 100 MD-Series Installation Guide 33
CHAPTER 2MD-Series Reference 
Introduction
This chapter includes the following reference information:
• A summary of maintenance procedures
• A table of camera specifications
• Information about standards referenced during the installation procedure
• A glossary of acronyms 
• A table comparing features of various MD-Series models
MD-Series Maintenance
The MD-Series components are designed for years of rugged, trouble-free use. 
Cleaning the Camera...

Page 34

 MD-Series Reference
34432-0010-00-12 Rev 100 — MD-Series Installation Guide 
window requires further cleaning, use a soft moist cotton-based cloth with 
isopropyl alcohol or dish soap.
Do not use abrasive materials, such as paper or scrub brushes as this will 
possibly damage the lens by scratching  it. Only wipe the lens clean when you 
can visually see contamination on the surface.
Cleaning the Camera Body
Do not use a pressure washer to clean the camera, as that could force water 
through the camera...

Page 35

432-0010-00-12 Rev 100 — MD-Series Installation Guide 35
 MD-Series Reference
MD-Series Specifications
Table 2.1 lists details about physical characteristics, power usage, and 
environmental features of the MD-Series camera. 
Table 2.1  Specifications
Physical Characteristics
Camera Size 5.2 cm (6 in) di ameter, 17.8 cm (7 in) tall
Camera Weight Under 1.4 kg (3 lb), depending on the camera model
Joystick Size 9.1 X 14.2 X 8.13 cm (3.6 X 5.6 X 3.2 in) 3.17 cm (1.25 in) above platform including joystick...

Page 36

 MD-Series Reference
36432-0010-00-12 Rev 100 — MD-Series Installation Guide 
External Standards
Table 2.2 lists other sources of information and standards definitions that may be 
useful during the installation of the MD-Series camera.
Table 2.2  External References
Standard Description
ANSI/SCTE 01 2006 “F” 
Port, Female, Outdoor  http://www.scte.org
IEC  60169-24 Radio-frequency coaxial connectors with screw coupling,  typically for use in 75 Ohm cable distribution systems 
(Type F)
IEC  60945...

Page 37

432-0010-00-12 Rev 100 — MD-Series Installation Guide 37
 MD-Series Reference
Acronyms 
Table 2.3 lists each acronym that is used in this manual and its meaning. 
Table 2.3  Acronyms
Acronym/Term Definition
AGC Automatic Gain Control
ANSI American National Standards Institute 
EAR Export Administra tion Regulations
EMI Electromagnetic Interference
FFC Flat Field Correction
FLIR Forward Looking Infrared
FoV Field of View
FPS Frames per Second (refresh rate)
HFoV Horizontal Field of View
ICD Interface...

Page 38

 MD-Series Reference
38432-0010-00-12 Rev 100 — MD-Series Installation Guide 
Feature Comparison of MD-Series Models 
Table 2.4 lists the two MD-Series models and supported features. Each model is 
available in four variations, identified by a unique part number:
• 

Page 39

432-0010-00-12 Rev 100 — MD-Series Installation Guide 39
 MD-Series Reference
Troubleshooting Tips
This section includes information that may help you with common issues that may 
arise during operation of the MD-Series system.
Video not displayed on monitor 
If the camera will not produce an image, check the video connection at the 
camera and at the display. If the connectors appear to be properly connected but 
the camera still does not produce an image, ensure that power has been properly 
applied to...

Page 40

 MD-Series Reference
40432-0010-00-12 Rev 100 — MD-Series Installation Guide 
Check cable connector terminations. Inferior quality connections may use 
multiple adapters that can cause unacceptable noise. 
Image too dark or too light
By default, the MD-Series thermal camera uses an automatic gain control (AGC) 
setting that has proven to be superior for  most applications. However, a specific 
environment may benefit from a different AG C setting. For example, a very cold 
background (such as the sky)...