Faroudja Fdp Dila1080phd Installation And Operations Manual
Here you can view all the pages of manual Faroudja Fdp Dila1080phd Installation And Operations Manual. The Faroudja manuals for Projector are available online for free. You can easily download all the documents as PDF.
Page 21
21 ON ENTER OFF FOCUSTEST MENUEXIT PRESETHIDE LIGHT OPERATE5-1 4 LAMP TEMPST AND BYOPERATE 4Hiding the image temporarily Press [HIDE] ●The displayed image will disappear. ● Press [HIDE] again to restore the image. 5Turning off the power 1 Press the OPERATE OFF button on this unit for 1 second or more ●The [OPERATE] indicator turns off, the [STAND BY] indicator starts blinking and this unit switches to the cool down mode. The cool down mode is to allow the temperature of the light source lamp to cool...
Page 22
22 Image adjust Set up Options InformationGREEN BLUE RED GammaNORMALNORMALACUSTCUSTOMOMBColor temp. Test patternUSER2USER2USER1USER1D65D65 ENTER Image adjust Options Inf ormationMenMenu Pu PositionositionMaskOffOff5%5%2.5%2.5%Source50P50P60P60PSet up Image adjust Set up Inf ormationPicture Shift Sleep time Flip V Menu display 15sec15secOnOnOnOnOffOff 15min15minOffOff30min30min60min60min960096001920019200 OnOn0OffOffFlip H RS232C(bps) Options Image adjust Set upLamp Time905h905h OptionsInf ormation Set...
Page 23
23 ON ENTER OFF FOCUSTEST MENUEXIT PRESETHIDE LIGHT OPERATE LAMPTEMP ST AND BYOPERA TE PRESET MENUEXIT ENTER HIDE MENUMENU ENTERENTER EXITEXIT ENTER ENTER Menu Operation Buttons The menus are operated using buttons on this unit or remote control unit\ . Button Function Displays the main menu. ●Press to clear the menu screen when the menu is displayed. Confirm the selected item on the main menu. ● Press [ENTER] when the “Test Pattern” item is selected to project the test pattern on the screen. After it is...
Page 24
24 LAMPTEMPST AND BYOPERA TE MENUEXIT ENTER 4 4 ON ENTER OFF FOCUSTEST MENUEXIT PRESETHIDE LIGHT OPERATE 1, 6 1, 6 2, 3 2, 3 1Press the [MENU] button ● The main menu is displayed on the screen. 2Press [ /] to select a main menu item and [ENTER] to confirm ● The “Information” menu does not have a setting menu (submenu). 3Press [ /] to select an adjustment item and [ / ] to change the setting value 4After setting is completed, press [EXIT] ● Each time you press the button, the menu returns to the...
Page 25
25 Item values shown in { } are factory settings. 1“Image adjust” Menu To adjust images. On the “Image adjust” menu, you can adjust the following items. “Gamma” Switches the gradation characteristics of the image. Select your preference setting values according to the image to be viewed. Setting Values :“NORMAL”, “A”, “B”, “CUSTOM” {“NORMAL”} “CUSTOM” :Use when setting Gamma with optional soft- ware. The picture quality is same as “NOR- MAL” for factory setting. “Color temp.” Adjusts the color...
Page 26
26 PRESET MENUEXIT ENTER HIDE ON ENTER OFF FOCUSTEST MENUEXIT PRESETHIDE LIGHT OPERATE 2, 5 2, 5 3, 4 3, 4 Screen Masking Images for which quality at the outer area has deteriorated can be proje\ cted by masking (hiding) the outer area of the projecte d image. 1 Project image onto the screen 2Press the [MENU] button ● The main menu is displayed on the screen. 3Press [ /] to select “Set up”, followed by pressing [ENTER] ● The “Set up” menu appears on the right side of the screen. 4Press [ /] to select...
Page 27
27 PRESET MENUEXIT ENTER HIDE ON ENTER OFF FOCUSTEST MENUEXIT PRESETHIDE LIGHT OPERATE 2, 5 2, 5 3, 4 3, 4 Image adjust Set up Options InformationGREEN BLUE RED Color temp. Test patternUSER2USER1D65 ENTERENTER GammaNORMALACUSTOMB Image adjust Set up Inf ormationPicture Shift Sleep timeSleep time Flip VOnOnOffOff 15min15minOff30min30min60min60min960096001920019200 OnOn0OffOffFlip H RS232C(bps) RS232C(bps) Options MenMenu display15sec15secOnOn Image adjust Set up Inf ormationSleep timeSleep time Flip...
Page 28
28 Light-source Lamp and Lamp Usage Time The light-source lamp has a service life. The life of lamps used for thi\ s unit is about 2000 hours. ●The lamp life of 2000 hours is merely the average life span of lamps and\ we do not provide any guarantee for this figure. The lamp life may not reach 2000 hours depending on the operating conditions\ . When the light-source lamp approaches the end of its service life, deter\ ioration progresses rapidly. Get ready or replace with a new lamp (lamp unit) when the...
Page 29
29 Handle Lamp Unit 2Loosen the screws on the lamp unit and lift up the handle ●Loosen the 2 screws with a screwdriver. 3Pull out the lamp unit 4Insert the new lamp unit until it is fully in 5Tighten the screws of the lamp unit and close the handle ●Fasten the 2 screws with a screwdriver. 6Attach the lamp cover and fasten the screws ●Fasten the 2 screws with a screwdriver. Caution Do not touch the glass surface of the lamp directly with your hand or stain it. Touching it with a bare hand may dirty...
Page 30
30 EXIT PRESET HIDE Resetting Lamp Time After installing a new lamp (lamp unit), reset the lamp time. The lamp\ time counter will be reset and a new count will start. If display of the accumulated lamp time has reached 2000 hours, this uni\ t will not work (lamp does not light up) unless the lamp time is reset. 1Insert plug into the power outlet ● The [STAND BY] indicator on the unit lights up when the main power is turned on. 2Press the [EXIT], [HIDE] and [PRESET] buttons se- quentially, then press [...