Epson Projector PT EZ590 User Manual
Have a look at the manual Epson Projector PT EZ590 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1734 Epson manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Chapter 5 Operation of Function — Web control function ENGLISH - 121 Descriptions of items 1 2 3 4 5 6 7 1 Page tab Pages are switched by clicking this item. 2 [Status] The status of the projector is displayed by clicking this item. 3 [Projector control] The [Projector control] page is displayed by clicking this item. 4 [Detailed set up] The [Detailed set up] page is displayed by clicking this item. 5 [Change password] The [Change password] page is displayed by clicking this item. 6 [Crestron Connected(TM)] The control page of Crestron Connected TM is displayed by clicking this item. 7 [Download] The download page of Presenter Light software is displayed by clicking this item. (x page 116) [Projector status] page Click [Status] → [Projector status]. Display the status of the projector for the following items. 14 15 6 7 8 9 1 2 3 4 5 10 11 12 13 1 [PROJECTOR TYPE] Displays the type of the projector. 2 [MAIN VERSION] Displays the firmware version of the projector. 3 [POWER] Displays the status of the power. 4 [SHUTTER] *1 Displays the status of the shutter (ON: closed, OFF: open). 5 [PICTURE MODE] Displays the setting status of [PICTURE MODE]. 6 [SERIAL NUMBER] Displays the serial number of the projector. 7 [LAMP POWER] Displays the setting status of [LAMP POWER]. 8 [VOLUME] Displays the volume status. 9 [REMOTE1 STATUS] Displays the status of the contact control. 10 [INPUT] Displays the status of the selected input. 11 [INTAKE AIR TEMPERATURE] Displays the status of the air intake temperature of the projector. 12 [EXHAUST AIR TEMPERATURE] Displays the status of the exhaust air temperature of the projector. 13 [LAMP RUNTIME] Displays the runtime of the lamps (converted value). 14 [SELF TEST] Displays the self-diagnosis information. 15 [PROJECTOR RUNTIME] Displays the runtime of the projector. *1 [SHUTTER] is for PT-EZ590, PT-EW650 and PT-EX620. [AV MUTE] is for PT-EW550 and PT-EX520. Displays the status of the AV mute. Error information page When [Error (Detail)] or [Warning (Detail)] is displayed in the self-diagnosis display of the [Projector status] screen, click it to display the error/warning details.
Chapter 5 Operation of Function — Web control function 122 - ENGLISH f The projector may go into the standby status to protect the projector de\ pending on the contents of the error. 11 Self-diagnosis result display Displays the item check results. [OK]: Indicates that operation is normal. [FAILED]: Indicates that there is a problem. [WARNING]: Indicates that there is a warning. r [FAILED] items displayed when a problem occurs Item Description [FAN] Trouble has occurred in the fan or its drive circuit. Consult your dealer. [FAN(R_B)] Trouble has occurred in the R/B panel cooling fan. [FAN(G)] Trouble has occurred in the G panel cooling fan. [FAN(PBS)] Trouble has occurred in the PBS cooling fan. [FAN(LAMP)] Trouble has occurred in the lamp cooling fan. [FAN(REAR)] Trouble has occurred in the rear fan. [FAN(POWER)] Trouble has occurred in the power cooling fan. [FAN(EXHAUST)] Trouble has occurred in the exhaust fan. [INTAKE AIR TEMPERATURE] The air intake temperature is too high. The projector may be used in an operating environment where the temperature is high, such as near a heating appliance. [EXHAUST AIR TEMPERATURE] The exhaust air temperature is high. The air exhaust port may be blocked. [LAMP REMAIN TIME] The lamp runtime has exceeded the prescribed cumulative time, and it is now time to replace the lamp. [LAMP STATUS] The lamp has failed to light. Wait a short while for the lamp to cool off, and then turn on the power. [APERTURE (CONTRAST-SHUTTER)] *1Trouble has occurred in the contrast shutter circuitry. Consult your dealer. [SHUTTER (MUTE-SHUTTER)] *1Trouble has occurred in the shutter circuitry. Consult your dealer. [INTAKE AIR TEMP.SENSOR] Trouble has occurred in the sensor used to detect intake air temperature.\ Consult your dealer. [EXHAUST AIR TEMP.SENSOR] Trouble has occurred in the sensor used to detect exhaust air temperature. Consult your dealer. [BATTERY] Battery replacement is required. Consult your dealer. [AIRFLOW SENSOR] Trouble has occurred in the sensor used to detect airflow. Consult your dealer. [LENS MOUNTER] Trouble has occurred in the lens mounter. Consult your dealer. [FILTER UNIT] The air filter unit is not attached. Check the attachment of the air filter unit. ( x page 139) [AIR FILTER] There is too much dust accumulated in the air filter unit. Turn the switch to ( x page 50), and clean the air filter. (x page 139) *1 Only for PT-EZ590, PT-EW650 and PT-EX620 [Network status] page Click [Status] → [Network status]. The current network setting status is displayed.
Chapter 5 Operation of Function — Web control function ENGLISH - 123 1 [WIRELESS LAN] Displays the configuration details of wireless LAN when the wireless module is attached. 2 [WIRED LAN] Displays the configuration details of wired LAN. [Access error log] page Click [Status] → [Access error log]. The error log on the web server is displayed such as access to the pages that do not exist or access with unauthorized user names or passwords. [Mail error log] page Click [Status] → [Mail error log]. Display E-mail error information if failed to send periodic E-mails. Note f [Access error log] and [Mail error log] display the recent few hundred accesses/requests. All information may not be displayed when many accesses/requests are made at a time. f When information in [Access error log] and [Mail error log] exceeds a certain amount, older information is erased. f Check [Access error log] and [Mail error log] periodically.
Chapter 5 Operation of Function — Web control function 124 - ENGLISH [Basic control] page Click [Projector control] → [Basic control]. 1 2 5 6 3 4 1 [INPUT] *1 Switches the input signal. 2 [VOLUME] Adjusts the volume. 3 [PICTURE MODE] Switches the picture mode. 4 [SHUTTER] *2 Switches the setting whether to use the shutter function (closing/ opening of the shutter). 5 [POWER] Turns on/off the power. 6 [CLOSED CAPTION] Switches the closed caption setting. *1 [DIGITAL LINK] is only for PT-EZ590, PT-EW650 and PT-EX620 *2 [SHUTTER] is for PT-EZ590, PT-EW650 and PT-EX620. [AV MUTE] is for PT-EW550 and PT-EX520,which switches the AV mute function on/off. [Advanced control] page Click [Projector control] → [Advanced control]. 1 2 3 1 [POSITION] Operates field angle-related settings. 2 [PICTURE] Operates picture quality settings. 3 [LENS] Adjusts the projection lens. [Network config] page Click [Detailed set up] → [Network config]. 1) Click [Network config]. f The [CAUTION!] screen is displayed.
Chapter 5 Operation of Function — Web control function ENGLISH - 125 2) Select the item which you want to change the setting, then click [Next].\ f The current setting is displayed. 3) Click [Change] button. f The setting change scr een is displayed. Wired LAN 2 1 3 4 5 6 7 8 1 [PROJECTOR NAME] Enters the name of the projector. Enter the host name if it is required when using a DHCP server etc. 2 [DHCP ON], [DHCP OFF ]Enables the DHCP client function, set to [DHCP ON]. 3 [IP ADDRESS] Enters the IP address when not using a DHCP server. 4 [SUBNET MASK] Enters the subnet mask when not using a DHCP server. 5 [DEFAULT GATEWAY] Enters the default gateway address when not using a DHCP server. 6 [DNS1] Enters the DNS1 server address. Permissible characters for the entry of DNS1 server address. (preferred): Numbers (0 - 9), period (.) (Example: 192.168.0.253) 7 [DNS2] Enters the DNS2 server address. Permissible characters for the entry of DNS2 server address. (alternate): Numbers (0 - 9), period (.) (Example: 192.168.0.254) 8 [Back], [Next] Click the [Back] button to return to the original screen. The current settings are displayed by pressing the [Next] button. Click the [Submit] button to update the settings. Note f When you use the “Forward” and “Back” functions of your browser, a warning message “Page has Expired” may appear. In that case, click [Network config] again since the following operation will not be guaranteed. f Changing LAN settings while connected to the LAN may cause the connection to cut out.
Chapter 5 Operation of Function — Web control function 126 - ENGLISH Wireless LAN (Only when the wireless module is attached) 1 2 3 4 5 6 1 [WIRELESS LAN] Selects [Enable] when you want to enable the wireless LAN function. 2 [SSID] Sets the SSID for use. 3 [CHANNEL] Selects the channel for use. 4 [ENCRYPTION] Selects [WPA2-PSK(AES)] when performing encrypted communications. 5 [KEY] Sets the key to be used when performing encrypted communications. 8 to 15 alphanumerics can be input. 6 [Back], [Change] Click the [Back] button to return to the original screen. The setting change screen is displayed by pressing the [Change] button. Click the [Submit] button to update the settings. Note f Changing LAN settings while connected to the LAN may cause the connection to cut out. f The setting values of the [Network config] page will return to the factory default when the [INITIALIZE] of the [NETWORK] menu is executed ( x page 110). f The [ENCRYPTION] is set to [DISABLE] in the factory default setting. If you want to communicate with wireless LAN, it is recommended that the [ENCRYPTION] is set to [WPA2-PSK (AES)] for security. [Ping test] page Check whether the network is connected to the E-mail server, POP server, DNS server, etc. Click [Detailed set up] → [Ping test]. 1 2 3 4 1 [Input IP address] Enter the IP address of the server to be tested. 2 [Submit] Executes the connection test. 3 Example of display when the connection has succeeded 4 Example of display when the connection has failed [ECO management set up] page Settings related to the ECO management function of the projector can be made. Click [Detailed set up] → [ECO management set up].
Chapter 5 Operation of Function — Web control function ENGLISH - 127 1 2 3 4 5 6 7 8 1 [LAMP POWER] Selects the [LAMP POWER] setting. 2 [AUTO POWER SAVE] Sets to [ON] when setting [AMBIENT LIGHT DETECTION], [SIGNAL DETECTION] and [SHUTTER DETECTION] *1. 3 [AMBIENT LIGHT DETECTION] Selects enable ([ON])/disable ([OFF]) of the environmental luminance interlock function. 4 [SIGNAL DETECTION] Selects enable ([ON])/disable ([OFF]) of the no signal interlock function. 5 [SHUTTER DETECTION] *1 Selects to enable ([ON])/disable ([OFF]) of the shutter interlock function. 6 [POWER MANAGEMENT] Selects the power consumption mode. 7 [TIMER] Selects the time that the lamp is turned off when the POWER MANAGEMENT function is using. 8 [Submit] Updates the settings. *1 [SHUTTER DETECTION] is for PT-EZ590, PT-EW650 and PT-EX620 [AV MUTE DETECTION] is for PT-EW550 and PT-EX520, it selects to enable ([ON])/disable ([OFF]) of the AV mute detection function. Note f For details of each setting item, refer to the [PROJECTOR SETUP] menu → [ECO MANAGEMENT] ( x page 93) on the projector. [E-mail set up] page When there is a problem or the runtime of a lamp reaches a set value, an E-mail can be sent to preset E-mail addresses (up to two addresses). Click [Detailed set up] → [E-mail set up]. 1 2 3 4 5 6 1 [ENABLE] Select [Enable] to use the E-mail function. 2 [SMTP SERVER NAME] Enter the IP address or the server name of the E-mail server (SMTP). To enter the server name, the DNS server needs to be set up. 3 [MAIL FROM] Enter the E-mail address of the projector. (Up to 63 characters in single byte) 4 [MEMO] Enter information such as the location of the projector that notifies the sender of the E-mail. (Up to 63 characters in single byte) 5 [MINIMUM TIME] Change the minimum interval for the temperature warning E-mail. The default value is 60 minutes. In this case, another E-mail will not be sent for 60 minutes after sending the temperature warning E-mail even if it reaches the warning temperature. 6 [INTAKE AIR TEMPERATURE] Change the temperature setting for the temperature warning mail. A temperature warning E-mail is sent when the temperature exceeds this value.
Chapter 5 Operation of Function — Web control function 128 - ENGLISH 8 7 9 8 7 7 [E-MAIL ADDRESS 1], [E-MAIL ADDRESS 2] Enter the E-mail address to be sent. Leave [E-MAIL ADDRESS 2] blank when two E-mail addresses are not to be used. 8 Settings of the conditions to send E-mail Selects the conditions to send E-mail. [MAIL CONTENTS]: Selects either [NORMAL] or [SIMPLE]. [ERROR]: Sends an E-mail when an error occurred in the self-diagnosis. [LAMP RUNTIME]: Sends an E-mail when the remaining time for the lamp has reached the value set at the right field. [INTAKE AIR TEMPERATURE]: Sends an E-mail when the air intake temperature has reached the value set at the above field. [PERIODIC REPORT]: Places a check mark on this to send an E-mail periodically. It will be sent on the days and the time with the check mark. 9 [Submit] Updates the settings. [Authentication set up] page Set the authentication items when POP authentication or SMTP authentication is necessary to send an E-mail. Click [Detailed set up] → [Authentication set up]. 1 2 3 4 5 6 7 8 1 [Auth] Selects the authentication method specified by your Internet service provider. 2 [SMTP Auth] Set when the SMTP authentication is selected. 3 [POP server name] Enter the POP server name. Allowed characters: Alphanumerics (A - Z, a - z, 0 - 9) Minus sign (-) and period (.) 4 [User name] Enter the user name for the POP server or the SMTP server. 5 [Password] Enter the password for the POP server or the SMTP server. 6 [SMTP server port] Enter the port number of the SMTP server. (Normally 25) 7 [POP server port] Enter the port number of the POP server. (Normally 110) 8 [Submit] Updates the settings. Contents of E-mail sent Example of E-mail sent when E-mail is set The following E-mail is sent when the E-mail settings have been established.
Chapter 5 Operation of Function — Web control function ENGLISH - 129 === Panasonic projector report(CONFIGURE) === Projector Type : PT-EZ590 Serial No : SH1234567 ----- E-mail setup data ----- TEMPERATURE WARNING SETUP MINIMUM TIME at [ 60] minutes interval INTAKE AIR TEMPERATURE Over [ 45 degC / 113 degF ] ERROR [ OFF ] LAMP RUNTIME [ OFF ] at REMAIN [ 400] H LAMP RUNTIME [ OFF ] at REMAIN [ 200] H INTAKE AIR TEMPERATURE [ OFF ] PERIODIC REPORT Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ OFF ] Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ] 00:00 [ OFF ] 01:00 [ OFF ] 02:00 [ OFF ] 03:00 [ OFF ] 04:00 [ OFF ] 05:00 [ OFF ] 06:00 [ OFF ] 07:00 [ OFF ] 08:00 [ OFF ] 09:00 [ OFF ] 10:00 [ OFF ] 11:00 [ OFF ] 12:00 [ OFF ] 13:00 [ OFF ] 14:00 [ OFF ] 15:00 [ OFF ] 16:00 [ OFF ] 17:00 [ OFF ] 18:00 [ OFF ] 19:00 [ OFF ] 20:00 [ OFF ] 21:00 [ OFF ] 22:00 [ OFF ] 23:00 [ OFF ] ----- check system ----- FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] EXHAUST AIR TEMPERATURE [ OK ] LAMP REMAIN TIME [ OK ] LAMP STATUS [ OK ] APERTURE(CONTRAST-SHUTTER)* 1 [ OK ] SHUTTER(MUTE-SHUTTER)*1 [ OK ] INTAKE AIR TEMP.SENSOR [ OK ] EXHAUST AIR TEMP.SENSOR [ OK ] BATTERY [ OK ] AIRFLOW SENSOR [ OK ] LENS MOUNTER [ OK ] FILTER UNIT [ OK ] AIR FILTER [ OK ] (Error code 00 00 00 00 00 00 00 00) Intake air temperature : 31 degC / 87 degF Exhaust air temperature : 37 degC / 98 degF PROJECTOR RUNTIME 600 H LAMP ECO 500 H LAMP NORMAL 100 H LAMP REMAIN 3500 H -------- Current status --------- MAIN VERSION 1.00 SUB VERSION 1.00 LAMP STATUS LAMP=ON INPUT HDMI1 SIGNAL NAME XGA60 SIGNAL FREQUENCY 0.00kHz / 0.00Hz REMOTE1 STATUS DISABLE ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 MAC address 04:20:9A:00:00:00 ----- Wireless Network configuration ----- DHCP Client OFF IP address 172.28.120.1 MAC address 00:40:63:00:00:00 Tue Apr 12 10:00:00 2016 ----- Memo ----- *1 Only for PT-EZ590, PT-EW650 and PT-EX620 Example of the E-mail sent for an error The following E-mail is sent when an error has occurred.
Chapter 5 Operation of Function — Web control function 130 - ENGLISH === Panasonic projector report(ERROR) === Projector Type : PT-EZ590 Serial No : SH1234567 ----- check system ----- FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] EXHAUST AIR TEMPERATURE [ OK ] LAMP REMAIN TIME [ OK ] LAMP STATUS [ OK ] APERTURE(CONTRAST-SHUTTER)* 1 [ OK ] SHUTTER(MUTE-SHUTTER)*1 [ OK ] INTAKE AIR TEMP.SENSOR [ OK ] EXHAUST AIR TEMP.SENSOR [ OK ] BATTERY [ OK ] AIRFLOW SENSOR [ OK ] LENS MOUNTER [ OK ] FILTER UNIT [ OK ] AIR FILTER [ FAILED ] (Error code 00 00 00 20 00 00 00 00) Intake air temperature : 31 degC / 87 degF Exhaust air temperature : 37 degC / 98 degF PROJECTOR RUNTIME 600 H LAMP ECO 500 H LAMP NORMAL 100 H LAMP REMAIN 3500 H -------- Current status --------- MAIN VERSION 1.00 SUB VERSION 1.00 LAMP STATUS LAMP=OFF INPUT HDMI1 ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 MAC address 04:20:9A:00:00:00 ----- Wireless Network configuration ----- DHCP Client OFF IP address 172.28.120.1 MAC address 00:40:63:00:00:00 Tue Apr 12 10:00:00 2016 ----- Memo ----- *1 Only for PT-EZ590, PT-EW650 and PT-EX620 [Adjust clock] page Click [Detailed set up] → [Adjust clock]. 1 2 3 4 5 6 7 1 [Time Zone] Selects the time zone. 2 [Set time zone] Updates the time zone setting. 3 [NTP SYNCHRONIZATION] Sets to [ON] to adjust the date and the time automatically. 4 [NTP SERVER NAME] Enter the IP address or server name of the NTP server when you set to adjust the date and the time manually. (To enter the server name, the DNS server needs to be set up.) 5 [Date] Enter the date to be changed. 6 [Time] Enter the time to be changed. 7 [Set date and time] Updates the date and the time settings.