Monitoring window layout 21 Monitoring window layout You can monitor using either of the window layouts below. •Grouping view This view lets you check the status of group registrations in a hierarchical diagram. •Detail list view This view lets you display the status of each projector as a list so that the projectors can be checked in detail. You can also display specific items as a list, and sort display items using a specific row as a sort key.•How to switch views Grouping view and Detail list view are switched as follows. Procedure Click the View menu, and select "Grouping view" or "Detail list view". Monitoring using Grouping viewMeanings of Grouping view icons In Grouping view, the patterns on the icons indicate the statuses of the projectors. If the group icons are round in shape, it indicates that there is another level below them. sp.22 Grouping view Detail list view
Monitoring window layout 22 The icon patterns and their meanings are explained below. *1 When Temperature level display group view is set to On at Environment setup in the Tool menu, an icon indicating the internal temperature of the projector will be displayed on top of the projector icon. The default setting is Off. As you can get an idea of how the temperature inside the projector is increasing when the temperature level is displayed, you can make improvements to the projector's operating environment before a high internal temperature error or high-temperature warning occur. sp.27 *2 Check the following items. - Check that the projector's power is turned on. - Check that the LAN cable is connected. - Check that Network Monitoring is set to ON or Standby Mode is set to Network ON in the projector's configuration menu. *3 Check that the projector has been correctly connected to the network.The projector information that is generated when a problem is detected is stored until EMP Monitor is closed. EMP Monitor displays will not be updated automatically even if the projector status returns to normal. Click "Refresh" in the main window to update the status. Using the icons in Grouping view The following icon operations can be carried out in Grouping view. Group No warnings or problems All projectors in the group are normal. Warning or problem A projector in the group has a warning or problem status. Notification A projector requiring immediate attention has been detected within the group. Monitoring disabled The projector is not being monitored. If you right-click the icon and select Monitoring enabled, the projector will be added to the projectors that are being monitored. Data being updated Projector No warnings or problems *1 Warning or problem Notification Monitoring disabled Data being updated Network error (monitor password authentication error) No Monitor Password was entered when the projector was registered, or an incorrect Monitor Password was entered.sp.12, p.15, p.17 Network error (TCP connection error) *2 Network error (ESC/VP.net communication error) *3 Projector
Monitoring window layout 23 •Expanding and collapsing icons Each time you double-click a group icon, the icons for the projector that have been registered in that group are displayed or hidden. •Moving icons To change the position of an icon within Grouping view, simply drag and drop the icon to be moved. Monitoring using Detail list viewMeanings of Detail list view icons The status of registered projectors is displayed as a list in Detail list view regardless of which groups the projectors belong to.
Monitoring window layout 24 The icon patterns and their meanings are explained below.Type: Displays the projector status. No warnings or problems *1 Warning or problem An error has occurred on the projector. Notification The projector requires immediate attention. Monitoring disabled The projector is not being monitored. If you right-click the icon and select Monitoring enabled, the projector will be added to the projectors that are being monitored. Data being updated Network error (monitor password authentication error) No Monitor Password was entered when the projector was registered, or an incorrect Monitor Password was entered. sp.12, p.15, p.17 Network error (TCP connection error) *2 Network error (ESC/VP.net communication error) *3 Group name: When projectors are registered to a group, the name of the group that the projector belongs to is displayed. Display name: Shows the display name. Power: Shows the power on status for the projector. Power on and normal status Power on and abnormal status Power off and normal status Power off and abnormal status Lamp Hours: Shows the lamp operating time for the projector. Temperature level: The following five icons display the differing internal temperature status of the projector. Internal temperature normalHigh-temperature warning Internal temperature normalInternal temperature error High-temperature warning Error information: Shows a notification or warning/problem status using the following icons. Clean Air Filter Notice Lamp Cover Open Replace Lamp *4 Lamp Error High-temperature warning Lamp failure at power on Replace Air Filter High internal temperature error No Air Filter Internal Error Low Air Flow Fan error Air Flow Sensor Err. Sensor error Low air flow error Supply System Error (Ballast) Air filter air flow sensor error Auto Iris Error Other error
Monitoring window layout 25 *1 When Temperature level display group view is set to On at Environment setup in the Tool menu, an icon indicating the internal temperature of the projector will be displayed on top of the projector icon. The default setting is Off. *2 Check the following items. - Check that the projector's power is turned on. - Check that the LAN cable is connected. - Check that Network Monitoring is set to ON or Standby Mode is set to Network ON in the projector's configuration menu. *3 Check that the projector has been correctly connected to the network. *4 You can display Replace lamp at any time preset at Environment setup in the Tool menu.•The projector information that is generated when a problem is detected is stored until EMP Monitor is closed. EMP Monitor displays will not be updated automatically even if the projector status returns to normal. Click "Refresh" in the main window to update the status. •Detectable error information differs with the projector you are using. Selecting display items You can select only the required items to be displayed in Detail list view.Procedure A Select "Option" from the View menu. The Option window will be displayed. B Select the check box of the item you want to display. C Click "OK". D When all of the details of the item cannot be displayed in Detail list view, drag the boundary line on the right of the item name so that the view is extended to the desired width.
Monitoring window layout 26 Sorting lists You can sort detailed lists by using a specific row as a sort key, such as projector name order or IP address order. Procedure Click the item name of the row you want to use as the sort key. Searching for desired icons (Projector list) The Projector list feature is useful for searching in lists when many groups and projectors are registered and the icon you are looking for is not displayed on screen. Procedure Select "Projector list" from the View menu. The following window will be displayed.With Projector list, temperature level icons are not displayed regardless of the setting of Temperature level display group view at Environment setup. The Projector list lets you check the registration details for groups in a hierarchical diagram. When you click on an icon, Grouping view and Detail list view are scrolled so that the selected icon is displayed in the window. Monitoring using the system tray The projector statuses are always displayed as icons in the system tray, even when Grouping view or Detail list view is not always displayed, and the statuses can be checked by the icon patterns. When the configuration menus are set using the following operations, an icon appears in the system tray and the status can be monitored by means of the icon's pattern. The icon patterns are explained below. ProcedureA Select "Environment setup" from the Tool menu. The Environment setup window will be displayed.No problem Problem
Monitoring window layout 27 B Select "Resident in the task tray". C Click "OK". •Right-click the icon in the system tray to open a pop-up menu to select the Open the main screen or Exit. •If Register at start up in the Environment set up is selected, EMP Monitor starts automatically when the computer's power is turned on. When using EMP Monitor under Windows Vista, you must have administrator authority in order to use this function. Displaying projectors with problem or warning statuses in a list You can display a list of only the projectors which have a problem or warning status. Procedure Select "Warning and Error Projector list" from the View menu. The following Warning and Error Projector list window will be displayed. If you move the mouse pointer over the icon of the Error information, details of the error and the remedy will be displayed. If you double-click in a line, the properties for that projector will be displayed. sp.29
Monitoring window layout 28 The icon patterns and their meanings are explained below. * You can display Replace lamp at any time preset at Environment setup in the Tool menu.Detectable error information differs with the projector you are using. Checking properties in detail You can check the properties of groups and projectors in detail. Displaying group properties Procedure You can use either of the following methods to display the proper- ties. •Displaying the properties for all groups in Grouping view Right-click in Grouping view and select Property. Type: Shows the group or projector status. Display name: Shows the display name. Power: Shows the power on status for the projector. Power on and normal status Power on and abnormal status Power off and normal status Power off and abnormal status Lamp Hours: Shows the lamp operating time for the projector. Source: Shows the input source that has been selected for the projector. Computer or Computer1 DVI or HDMI (Digital) Computer2 D-Video BNC Easy MP S-Video USB Display Video(RCA) USB Video(BNC) LAN Temperature level: The following five icons display the differing internal temperature status of the projector. Internal temperature normalHigh-temperature warning Internal temperature normalInternal temperature error High-temperature warning Error information: Shows the warning or problem status using the following icons. Replace Lamp * Lamp Error High-temperature warning Lamp failure at power on Replace Air Filter High internal temperature error No Air Filter Internal Error Low Air Flow Fan error Air Flow Sensor Err. Sensor error Low air flow error Supply System Error (Ballast) Air filter air flow sensor error Auto Iris Error Lamp Cover Open Other error
Monitoring window layout 29 •Displaying properties for specified groups Right-click an icon in Grouping view and then select Property. If you double-click in a line, the properties for that group or projector will be displayed. Displaying projector properties Right-click on a projector icon in Grouping view or Detail list view and select Property. Displaying and deleting logs In your web browser, you can check a transmission log of content such as what has been controlled by EMP Monitor, projector errors. You can delete logs once you have checked them.1 Shows the projector's serial number. If hyphens are displayed, confirm the serial number on the label of the projector. 2 Displays the projector firmware version. B A
Monitoring window layout 30 When Log output is set to On at Environment setup in the Tool menu, transmission logs are stored. The default setting is Off. Displaying logs Procedure Select "Log" - "View" from the View menu. The web browser will open and the communication logs up until that time will be displayed. Deleting logs Procedure Select "Log" - "Delete" from the View menu. When the confirma- tion message is displayed, click "OK". All logs will be deleted and details of EMP Monitor control operations and details of projector errors from that point onward will be recorded in a new log.