Epson Monitor V4.30 User Manual
Have a look at the manual Epson Monitor V4.30 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1734 Epson manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Registering and deleting projectors for monitoring 11 Registering projectors using automatic search (Searching for and registering projectors that are located in the same segment)Procedures for automatic search ProcedureA Right-click in Grouping view and select "New" - "Projector (automatic search)". The Create new projector (automatic registration) window will be displayed. If Detail list view is displayed, select "New" - "Projector (automatic search)" from the Edit menu. B Click "Search". Automatic searching will be carried out, and the names of the pro- jectors that have been detected will be displayed. If a projector does not appear in the list, use "Registration by spec- ifying an IP address (Manual registration)". sp.17 •You can also carry out this operation by selecting New - Projector (automatic search) from the Edit menu. •Projectors that are using a serial TCP/IP conversion adapter cannot be detected.
Registering and deleting projectors for monitoring 12 Procedures for registration ProcedureA Select the projector(s) to be registered from the displayed list, and then click "Edit". The following window will be displayed. Make the necessary settings while referring to the following table. Display nameEnter the name of the projector(s) to be displayed in Grouping view or Detail list view. Up to a maximum of 32 bytes can be entered. A space cannot be used as the first character. Display iconSelect the icon(s) to be displayed in Grouping view or Detail list view. Parent groupSelect when registering a projector in a group. If no groups have been created, this cannot be selected. s"Registering several projectors to a monitoring group all at once" p.18 Projector nameThis shows the name that has been registered on the projector. IP addressThis shows the IP address for the registered projector. Use Serial TCP/IP conversion adaptor.This cannot be selected when registering projectors using automatic search. Port NumberThis cannot be selected when registering projectors using automatic search. Monitor PasswordIf a Monitor Password has been set for the projector, be sure to enter the Monitor Password that has been set. If the correct password is not entered at this time, it will not be possible to monitor and control the projector even though it is registered. DescriptionYou can enter some kind of memo about the projector. The details you enter here will be displayed at the projector properties. Up to a maximum of 60 bytes can be entered. MonitorSelect this when you want monitoring to start.
Registering and deleting projectors for monitoring 13 B After entering the details, click "Register" to start the registration. When the message is displayed, click "OK". To continue registering other projector(s), repeat Steps 1 and 2. Projectors that have been registered using automatic search are searched for again by projector name each time EMP Monitor is started. C To end the registration operation, click in the top-right corner of the window or click "Cancel". The icon(s) of the projector(s) you registered will be displayed in Grouping view or Detail list view. Refer to s"Monitoring window layout" p.21 for details on using the Grouping view and Detail list view. Setting the range of addresses to do an automatic search and registration Projectors that are using a serial TCP/IP conversion adapter cannot be detected. Procedures for automatic search ProcedureA Right-click in Grouping view and select "New" - "Projector (automatic search)". The Create new projector (automatic registration) window will be displayed. If Detail list view is displayed, select New - Projector (automatic search) from the Edit menu. B Select the "Specify an address range and search" check box and then enter "Start address" and "End address" in the range.
Registering and deleting projectors for monitoring 14 C Click "Search". Automatic searching will be carried out, and the names of the pro- jectors that have been detected will be displayed.
Registering and deleting projectors for monitoring 15 Procedures for registration ProcedureA Select the projector(s) to be registerd from the displayed list, and then click "Edit". The following window will be displayed. Make the necessary settings while referring to the following table. Display nameEnter the name of the projector(s) to be displayed in Grouping view or Detail list view. Up to a maximum of 32 bytes can be entered. A space cannot be used as the first character. Display iconSelect the icon(s) to be displayed in Grouping view or Detail list view. Parent groupSelect when registering a projector in a group. If no groups have been created, this cannot be selected. s"Registering several projectors to a monitoring group all at once" p.18 Projector nameThis shows the name that has been registered on the projector. IP addressThis shows the IP address for the registered projector. Use Serial TCP/IP conversion adaptor.This cannot be selected when registering projectors using automatic search. Port NumberThis cannot be selected when registering projectors using automatic search. Monitor PasswordIf a Monitor Password has been set for the projector, be sure to enter the Monitor Password that has been set. If the correct password is not entered at this time, it will not be possible to monitor and control the projector even though it is registered. DescriptionYou can enter some kind of memo about the projector. The details you enter here will be displayed at the projector properties. Up to a maximum of 60 bytes can be entered. MonitorSelect this when you want monitoring to start.
Registering and deleting projectors for monitoring 16 B After entering the details, click "Register" to start the registration. When the message is displayed, click "OK". To continue registering other projector(s), repeat Steps 1 and 2. C To end the registration operation, click in the top-right corner of the window or click "Cancel". The icon(s) of the projector(s) you registered will be displayed in Grouping view or Detail list view. Refer to s"Monitoring window layout" p.21 for details on using the Grouping view and Detail list view.
Registering and deleting projectors for monitoring 17 Registration by specifying an IP address (Manual registration) ProcedureA Right-click in Grouping view and select "New" - "Projector (manual registration)". The following window will be displayed. If Detail list view is displayed, select "New" - "Projector (manual registration)" from the Edit menu.You can also carry out this operation by selecting New - Projector (manual registration) from the Edit menu. B Enter the IP address of the projector to be registered in the "IP address" box and then click "Search". When the message is displayed, click "OK". If using a serial TCP/IP conversion adapter and cable to connect the projector, select Use Serial TCP/IP conversion adaptor. Enter the port number in Port Number and then click Search. C After searching is complete, enter the information for the projector to be registered while referring to the table below.Display nameEnter the name of the projector(s) to be displayed in Grouping view or Detail list view. Up to a maximum of 32 bytes can be entered. A space cannot be used as the first character. Display iconSelect the icon(s) to be displayed in Grouping view or Detail list view. Parent groupSelect when registering a projector in a group. If no groups have been created, this cannot be selected. s"Registering several projectors to a monitoring group all at once" p.18 Projector nameThis shows the name that has been registered on the projector. IP addressThis shows the IP address that you entered in step 2. Use Serial TCP/IP conversion adaptor.Select this if using a serial TCP/IP conversion adapter to connect the projector.
Registering and deleting projectors for monitoring 18 D After entering the details, click "Register" to start the registration. When the message is displayed, click "OK". The icon(s) of the projector(s) you registered will be displayed in Grouping view or Detail list view. Registering several projectors to a monitoring group all at once Projectors that have been registered can then be registered together into different groups so that they can be monitored and controlled together. Furthermore, if you select one of the registered groups as the Parent group, monitoring and control operations can be carried out for all projectors in that Parent group. A Parent group can be set for other parent groups, so that a hierarchical group arrangement can be created. First, create the registration groups, and then register projectors into the groups that have been created. Port NumberIf using a serial TCP/IP conversion adapter to connect the projector, enter the port number. Monitor PasswordIf a Monitor Password has been set for the projector, be sure to enter the Monitor Password that has been set. If the correct password is not entered at this time, it will not be possible to monitor and control the projector even though it is registered. If using a serial TCP/IP conversion adapter to connect the projector, the Monitor Password security function cannot be used. DescriptionYou can enter some kind of memo about the projector. The details you enter here will be displayed at the projector properties. Up to a maximum of 60 bytes can be entered. MonitorSelect this when you want monitoring to start.
Registering and deleting projectors for monitoring 19 ProcedureA Right-click in Grouping view and select "New" - "Group". The following window will be displayed. Make the necessary settings while referring to the table below. If Detail list view is displayed, select New - Group from the Edit menu. You can also carry out this operation by selecting New - Group from the Edit menu. B When the setup is complete, click "Register" to start the registration. When the message is displayed, click "OK". The icon(s) of the projector(s) you registered will be displayed in Grouping view or Detail list view. C Right-click the projector icon(s) to register to the group you have created in Grouping view or Detail list view, and select "Edit". You can also carry out this operation by selecting Edit in the Edit menu. D In the Edit projector window, select the group name to use for registering in Parent group and then click "Change". The status of the group registration will be displayed as an icon in Grouping view or Detail list view. The registration details can also be checked using Projector list in the View menu. Group nameEnter the name of the group to be displayed in Grouping view or Detail list view. Up to a maximum of 32 bytes can be entered. A space cannot be used as the first character. Display iconSelect the icon(s) to be displayed in Grouping view or Detail list view. Parent groupThis selects the parent group. If no groups have been created, this cannot be selected. MonitorSelect this to monitor all projectors that have been registered in the group. If this is not selected, the settings made when the individual projectors were registered will be used. It cannot be set when creating a new group.
Registering and deleting projectors for monitoring 20 If the projector name or IP address changes after registrationFor projectors that have been registered manually ProcedureA Right-click on a projector icon in Grouping view or Detail list view and select "Monitoring disabled". Then right-click the projector icon again and select "Edit". You can also carry out these operations by using the Edit menu. B If only the projector name has been changed, click "Search" in the Edit projector window that is displayed. If the IP address has been changed, enter the new IP address in the "IP address" box and then click "Search". When the message is displayed, click "OK". C When the display returns to the Edit projector window, click "Change". For projectors that have been registered using automatic search ProcedureA Delete the projector(s) whose name or IP address has been changed in Grouping view or Detail list view.sp.20 B Carry out automatic search to re-register the projector(s). sp.11 Cancelling (deleting) projector registrations The registrations for projectors can be deleted if they are no longer required for monitoring or control using EMP Monitor. Procedure Right-click the icon for the projector or group that is to be deleted in Grouping view or Detail list view and select "Delete". When the message is displayed, click "OK". More than one projector can be selected for deleting by selecting in Grouping view or Detail list view. The methods of selecting more than one projector at the same time are as follow. •If you select a group icon in Grouping view, all projectors that have been registered in that group will be deleted at the same time. •Hold down the Ctrl key on the keyboard while clicking on the desired icons. •Use drag and drop to select a range of desired icons. You can also carry out this operation by selecting Delete in the Edit menu.