Page 91
89 DHCP Client Setting Connect the LAN cable before turning the pro- jector on. If not, the DHCP Client function does not work. Menu operation Page 58 Example: “Options (2)” screen menu Description of DHCP Client Note •Select “ON” for “DHCP Client”. “Obtaining IP Address...” appears, then the message “The network settings have been changed.”, IP Address, Subnet Mask and Gateway will be displayed. • If the DHCP server is not available, “Could not obtain IP Address.” appears. In this case, set the TCP/IP...
Page 92
90 Description Factory default setting: 192.168.150.002 Enter an IP address appropriate for the network. Factory default setting: 255.255.255.000 Set the subnet mask to the same as that of the computer and equipment on the network. Factory default setting: 000. 000. 000. 000 * When not in use, set to: “000. 000. 000. 000”. Selectable items IP Address Subnet Mask Gateway Description of TCP/IP Note • Before setting “TCP/IP”, select “OFF” for “DHCP Client”. • Confirm the existing network’s segment (IP...
Page 93
91 Returning to the Default Settings This function allows you to initialize the settings you have made in the projector. Menu operation Page 56 Example: “Options (2)” screen menu Note About the network settings •“IP Address”, “Subnet Mask”, “Gateway” and other network setting items are initialized. The following items or menu cannot be initialized. • “C. M. S.” menu “Lightness”, “Chroma” and “Hue” respectively saved for Custom 1-3 on the “C.M.S.” menu. • “Fine Sync” menu Special Modes • “Options (1)”...
Page 94
92 Selecting the On-screen Display Language The projector can switch the on-screen display language among 11 languages: English, German, Spanish, Dutch, French, Italian, Swedish, Portu- guese, Chinese, Korean or Japanese. Menu operation Page 58 Example: “Language” screen menu Using the Other Menus (“Language” and “Status” menus) Overview of All Menu Set- tings This function can be used to display all the ad- justed settings as a list on the screen. Menu operation Page 56 Example: “Status” screen menu
Page 95
93 Cleaning the air vents and the intake vent cover ■Use a vacuum cleaner to clean dust from the ex- haust vent, the intake vents and the intake vent cover (on the bottom of the projector). Info •If you want to clean the air vents and the intake vent cover during projector operation, ensure you press on the projector or on the remote control and put the projector into standby mode. After the cooling fan has stopped, unplug the power cord from the AC socket and clean the air vents and the intake vent...
Page 96
94 Power indicator Lamp indicators 1, 2 Temperature warning indicator Maintenance Indicators Maintenance Indicators ■The warning lights on the projector indicate problems inside the project\ or. ■ If a problem occurs, either the temperature warning indicator or the lam\ p indicator will illuminate red, and the projector will enter the standby mode. After the projector has entered the standby mode, follow the procedures given below. About the temperature warning indicator If the temperature inside the...
Page 97
95 Maintenance indicatorProblemCause Possible solution Temperature warning indicator Normal Abnormal Off Red on (Standby) The internal temperature is abnormally high. Abnormal • Blocked air intake • Relocate the projector to an area with proper ventilation. (See page 9.) • Cooling fan break- down • Internal circuit failure • Clogged air intake • Clogged intake vent cover • Take the projector to your nearest EIKI Authorized Dealer or Service Center for repair. • Clean the air vents and the intake vent...
Page 98
96 Lamp ■It is recommended that the lamp units (optional: AH-50001 and AH-50002) be replaced when the re- maining lamp life becomes 5% or less, or when you notice a significant d\ eterioration in the picture and color quality. The lamp life (percentage) can be checked with the on-screen display\ . See page 83. ■ Purchase a replacement lamp unit of type AH-50001 and AH-50002 from your place of purchase, nearest EIKI Authorized Dealer or Service Center. Hg LAMP CONTAINS MERCURY For State Lamp Disposal...
Page 99
97 Optional accessories Lamp unit 1 AH-50001Removing and Installing the Lamp Unit Info • Make sure that you remove the lamp unit by the handle. Do not touch the glass sur- face of the lamp unit or the inside of the projector. • To avoid injury to yourself and damage to the lamp, make sure you carefully follow the steps below. • Do not loosen other screws except for the lamp unit cover and lamp unit. (Only the silver screws are loosened.) 1Press on the projector or on the remote control to put the...
Page 100
98 4Remove the lamp unit. •Loosen the securing screws (two for each lamp) from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it. 5Insert the new lamp unit. •Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws. • Be sure that AH-50001 and AH-50002 are respective type. 6Replace the lamp unit cover. •Align the lamp unit cover and slide it to close. Then tighten the user...