Page 31

31
Recording
● sensitivity/Input level knobs
These knobs adjust sensitivity/input levels.
When recording in stereo x2, these knobs control the following signals.
Channel 1STEREO 1 L-channelSENS/INPUT LEVEL 1 knob
Channel 2STEREO 1 R-channelSENS/INPUT LEVEL 2 knob
Channel 3STEREO 2 L-channelSENS/INPUT LEVEL 3 knob
Channel 4STEREO 2 R-channelSENS/INPUT LEVEL 4 knob
Adjusting the input level
1.Turn the input level knob [SENS] (outer) all the way left.
2.Turn the input level knobs [LEVEL] (inner) to the...

Page 32

32
Recording
● Record button [REC]
If you want to begin recording immediately, press the [REC] button.
● Other settings
If you want to monitor the sound being recorded, connect headphones to the PHONES jack and use the 
monitor level knob to adjust the volume.
Adjusting the monitor level knob does not affect the level of the sound actually being recorded.
To play back the recorded sound, refer to “Playing back” (p. 37).
Recording standby
If you want to put the R-4 Pro in recording standby 
mode to be...

Page 33

33
Recording
The following describes how to record an audio source via the R-4 Pro internal mics.
● Phantom power switch
Turn this OFF.fig.input-intmic.eps
● System settings
Press the R-4 Pro [SYSTEM] button.
In 1 Recording Setup, set Input Select to IntMic.
Set the other items in 1 Recording Setup as appropriate for the 
recording you want to make.
* For more about system settings, refer to “System setup” (p. 64).
* The limiter and input level knob [SENS] settings are invalid.
* The internal mics cannot...

Page 34

34
Recording
The following describes how to record from a digital device connected to the R-4 Pro digital input 
connector.
fig.digital.eps
● Connections
Connect your digital device to the digital input connector. You will need a separately available XLR type 
cable to connect your device to the R-4 Pro digital input connector.
fig.input-digital.eps
● System settings
1.Press the R-4 Pro [SYSTEM] button.
2.1 Recording Setup, set Input Select to Digital.
3.Set the sampling frequency to match the input...

Page 35

35
Recording
You can record sound from both mics connected to R-4 Pro XLR input connectors 3 and 4 and a digital 
device connected to the digital input connector.
fig.input-analog.eps
● System settings
Press the R-4 Pro [SYSTEM] button.
In 1 Recording Setup, set Input Select to Dig+Ana.
Set the Rec Mode to STEREOx2.
Set the other items in 1 Recording Setup as appropriate for the 
recording you want to make.
* For more about system settings, refer to “System setup” (p. 64).
● Input level knobs
Adjust the...

Page 36

36
Recording
You can record sound both from the mics connected to R-4 Pro XLR input connectors 3 and 4 and the 
internal mics.
fig.input-analog.eps
● System settings
Press the R-4 Pro [SYSTEM] button.
In 1 Recording Setup, set Input Select to Int+Ana.
Set the Rec Mode to STEREOx2.
Set the other items in 1 Recording Setup as appropriate for the 
recording you want to make.
* The internal mics cannot be used if the Rec Freq is set to 192 kHz. 
If Rec Freq is set to 192 kHz after setting Int+Ana, the...

Page 37

37
Playing back
This section explains how to play back audio recorded on the R-4 Pro and projects on the R-4 Pro internal 
hard disk. Make the correct settings and connections before playing anything back.
•Connections before playback..............................  (p. 37)
•Setup before playback...........................................  (p. 39)
•Playing back.............................................................  (p. 41)
Headphones are a convenient way to monitor while recording or to check sound...

Page 38

38
Playing back
The following describes how to connect devices with digital input ports, such as mixers, speakers, or 
recording devices.
fig.basic-disp.epsThe sampling frequency of the project playing back will be the 
sampling frequency of the audio output from the digital output 
connector.
1.Switch off the power to the R-4 Pro.
2.Turn off power to the device with the digital input port.
3.Connect the R-4 Pro digital output connector [DIGITAL OUT] to the digital 
input connector of the device with...

Page 39

39
Playing back
fig.recording-1.eps
1Press the R-4 Pro [SYSTEM] button.
The system menu screen appears in the display.
fig.player-setup2.eps
2Use the [CURSOR] buttons to choose 2 Player Setup, and 
press the [ENTER] button.
The Player Setup screen appears.
3Use the [SCRUB/VALUE] dial to choose the Play Mode 
value.
* The setting is applied as soon as you select it. You do not need to press the [ENTER] button.
You can also setup the following items. 
* The values in boldface are the default values.
* For...

Page 40

40
Playing back
You can use the R-4 Pro internal speakers to monitor the sound without having to connect headphones or 
other equipment.
fig.recording-1.eps
1Press the R-4 Pro [SYSTEM] button.
The system menu screen appears in the display.
fig.speaker-on.eps
2Use the [CURSOR] buttons to choose 3 Speaker, and 
press the [ENTER] button.
The Speaker screen appears.
* The values in boldface are the default values.
* You cannot monitor with the internal speakers while recording. You will need to monitor...