Home > DuVoice > Communications System > DuVoice Mitel SX50 COV Instructions

DuVoice Mitel SX50 COV Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual DuVoice Mitel SX50 COV Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 17 DuVoice manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							  07/27/00  
     Integration Notes-Switch #534  
     
    Mitel SX50 COV 
     
    Introduction  
    This file gives basic information on integrating the Duvoice VM with Mitel SX50 
    telephone system.  Refer to the Mitel programming for more information. 
               
    Switch Hardware Required 
    ·  Mitel SX50 telephone system with MS55 software.        
    ·  One extension on a COV/Superset 4 card per Duvoice VM port is required.   
    ·  One analog extension for the modem is recommended.  If no extensions are 
    available wire a 
             trunk line to the modem using a TKM switch. 
     
    Switch Programming 
     
    Command 100  System Options 
         REG 03(Tone And Ringing Control) = 0301411000 BIT h=0 Disconnect Tone:Disable 
         REG 12(Message Waiting) = 121030 BIT c=1,BIT d=0, BIT f=0 
     
    Command 110 Feature Access Code Programming 
         REG19(Hunt Group 1 Access Code) = 19491  Hunt Group Access Code =491 
     
    COS Programming:  Create COS 9 For VM 
    Command 129 COS 9 Programming 
         REG 2 21100010001 
      BIT a(Register)=2(Register 2) 
      BIT b(Switchhook/Ground Button Flash=1(Flash for Consultation Hold) 
      BIT c(Call Direction)=1(Bothway Calling) 
      BIT g(Message Waiting)=1(Enabled) 
      BIT k(Do Not Disturb)=1 
         REG 3 30011000001 
      BIT a(Register)=3(Register 3) 
      BIT d(Data Line Security)=1(Enabled) 
      BIT e(Call Hold)=1(Enabled) 
      BIT k(Voice Mail Port)=2(Message Optimization Control) 
         REG 4 4111100100 
      BIT a(Register)=4(Register 4) 
      BIT b(Call Forward-Follow Me)=1(Internal Only) 
      BIT c(Call Forward-Busy)=1(Internal Only) 
      BIT d(Call Forward-No Answer)=1(Internal Only) 
      BIT e(Call Forward Busy/No Answer)=1(Internal Only) 
      BIT h(Executive Busy Override Security)=1(Enabled) 
         REG 5 50000000000 
      BIT a(Register)=5(Register 5)  
    						
    							  07/27/00    BIT b-j(Abbreviated Dial Numbers)=0(Disabled) 
     
    Switch Programming Continued… 
     
     
     
         REG 7 71010100 
      BIT a(Register)=7(Register 7) 
      BIT b(Superset4/420 Telephone message Programming)=1(Enabled) 
      BIT d(Auxiliary Attendant Position)=1(Enabled) 
      BIT f(Directed Call Pickup Security)=1(Enabled) 
         REG 8 80000 
      BIT a(Register)=8(Register 8) 
      BIT b(Extension Camp-on)=0(Disabled) 
      BIT c(Trunk Camp-on)=0(Disabled) 
      BIT d(Inward Dial Trunk Camp-on)=0(Disabled) 
     
    Superset/Station Programming:   Example Slot 4 Programming 
     Command 304 
      01090000301 
      02090000302 
      03090000303 
      04090000304 
      05090000305 
      06090000306 
      07090000307 
      08090000308 
      BIT a and b(Circuit Number 01-08 for COV and DNIC Cards) 
      BIT c(Extension Type)=0(Extension) 
      BIT d(Class Of Service) 
      BIT e(Allow Attendant to Change Extension COS)=0(Not Allowed) 
      BIT f(Pickup Group)=0(No Pickup Group) 
      BIT g(ARS Routing Class of Service)=0(ARS Route does not apply) 
      BIT h(OPS Loop Length)=0(Short) 
      BIT i,j,k, and l(Extension Number) 
     
     Command 361 Hunt Group Programming 
      REG 1     100 
         BIT a(Register)=1(Register 1) 
         BIT b(Hunt Type)=0(Circular) 
         BIT c(Hunt Group Linking)=0(Unlinked) 
      REG 2-9 2301 
                      3302 
         4303 
         5304 
         BIT a(Hunt Group Member Number) 
         BIT b,c,d and e(Hunt Group Member Extension Number) 
     
    Message Waiting Port Should Be In The Hunt Group 
      
    						
    							  07/27/00  Command 425-4     Station Programming MWI Lines 
         REG 1: Extensions 301-304 
         01111301 
         01111302 
         01111303 
         01111304 
     
    Switch Programming Continued… 
     
     
    Command 501 Trunk Programming (Auto Attendant Day And Night) 
         REG 4 40501610000 Hunt Group 161 
      BIT a(Register)=4(Register 4) 
      BIT b(Dictation Trunk)=0(Disabled) 
      BIT c(Inter-ringing Delay)=5(5seconds) 
      BIT d(Day Answer Mode)=0(Direct-In-Line) 
      BIT e,f, and g(Day Answer Point)=161(Hunt Group 161) 
      BIT h(Busy Intercept)=0(Disabled) 
      BIT i(Do Not Disturb Intercept)=0(Disabled) 
      BIT j(No Answer Intercept)=0(Disabled) 
      BIT k(Illegal/Vacant Number Intercept)=0(Disabled) 
     
         REG 5 501610000 Hunt Group 161 
      BIT a(Register)=5(Register 5) 
      BIT b(Night Answer Mode)=0(Flexible Night Service) 
      BIT c,d, and e(Night Answer Point)=161(Hunt Group Number) 
      BIT f(DID Night Answer Point)=0(Disabled) 
     
    Call Forward Busy/No Answer Code 60 Command 110.  Program Call Froward Busy/No 
    Answer Into Room COS.   Program Each Room To Call Forward To VM Hunt Group 
    491(60 491).  Call Forward VM Ports For No Answer To Operator Extension. 
     
    VM Programming 
     
    Program VM With Switch Integration 534. 
      
    						