71 MessageDescription The internal temperature is rising. The projector is operating in low power. Please turn the power off, and allow the projector to cool down at least 20 minutes. After having confirmed the following items, please turn the power ON again. • Is there blockage of the air passage aperture? • Is the air filter dirty? If so, please clean or replace the air filter ( 67, 68). • Does the peripheral temperature exceed 35°C? • If t he projector is used at an altitude of about 1600 m (5250 feet) or higher, set ALTITUDE of the SERVICE item in the OPTION menu to HIGH ( 57). If the projector is used with a wrong setting, it may cause damage to the projector itself or the parts inside. A note of precaution when cleaning the air filter. Please immediately turn the power off, and clean or change the air filter referring to the Cleaning and replacing the air filter section of this manual. After you have cleaned or changed the air filter, please be sure to reset the filter timer ( 55, 67). The button operation is not available. Troubleshooting Related messages (continued)
![](/img/blank.gif)
72 Troubleshooting Regarding the indicator lamps When operation of the LAMP, TEMP and POWER indicators differs from usual, check and cope with it according to the following table. POWER indicator LAMP indicator TEMP indicator Description Lighting In Orange Turned off Turned off The projector is in a standby state.Please refer to the section “Power on/off”. Blinking In Green Turned off Turned off The projector is warming up.Please wait. Lighting In Green Turned off Turned off The projector is in an on state.Ordinary operations may be performed. Blinking In Orange Turned off Turned off The projector is cooling down.Please wait. Blinking In Red (discre- tionary)(discre- tionary) The projector is cooling down. A certain error has been detected. Please wait until POWER indicator finishes blinking, and then perform the proper measure using the item descriptions below. Blinking In Red or Lighting In Red Lighting In Red Turned off The lamp does not light, and there is a possibility that interior portion has become heated. Please turn the power off, and allow the projector to cool down at least 20 minutes. After the projector has sufficiently cooled down, please make confirmation of the following items, and then turn the power on again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 35°C? If the same indication is displayed after the remedy, please change the lamp referring to the section Replacing the lamp . Blinking In Red or Lighting In Red Blinking In Red Turned off The lamp cover has not been properly fixed. Please turn the power off, and allow the projector to cool down at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp cover. After performing any needed maintenance, turn the power on again. If the same indication is displayed after the remedy, please contact your dealer or service company. (continued on next page)
![](/img/blank.gif)
73 Troubleshooting Regarding the indicator lamps (continued) POWER indicator LAMP indicator TEMP indicator Description Blinking In Red or Lighting In Red Turned off Blinking In Red The cooling fan is not operating.Please turn the power off, and allow the projector to cool down at least 20 minutes. After the projector has sufficiently cooled down, please make confirmation that no foreign matter has become caught in the fan, etc., and then turn the power on again. If the same indication is displayed after the remedy, please contact your dealer or service company. Blinking In Red or Lighting In Red Turned off Lighting In Red There is a possibility that the interior portion has become heated. Please turn the power off, and allow the projector to cool down at least 20 minutes. After the projector has sufficiently cooled down, please make confirmation of the following items, and then turn the power on again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 35°C? • If the projector is used at an altitude of about 1600 m (5250 feet) or higher, set ALTITUDE of the SERVICE item in the OPTION menu to HIGH ( 57). If the projector is used with a wrong setting, it may cause damage to the projector itself or the parts inside. Lighting In Green Simultaneous blinking in Red It is time to clean the air filter.Please immediately turn the power off, and clean or change the air filter referring to the section Cleaning and replacing the air filter. After cleaning or changing the air filter, please be sure to reset the filter timer. After the remedy, reset the power to ON. Lighting In Green Alternative blinking in Red There is a possibility that the interior portion has become overcooled. Please use the unit within the usage temperature parameters (5°C to 35°C). After the treatment, reset the power to ON. (continued on next page)
![](/img/blank.gif)
74 Troubleshooting Regarding the indicator lamps (continued) • When the interior portion has become overheated, for safety purposes, the projector is automatically shut down, and the indicator lamps may also be turned off. In such a case, disconnect the power cord, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again. If the projector is used at an altitude of about 1600 m (5250 feet) or higher, set ALTITUDE of the SERVICE item in the OPTION menu to HIGH ( 57). Otherwise, set it to NORMAL. NOTE
![](/img/blank.gif)
75 Troubleshooting Resetting all settings When it is hard to correct some wrong settings, the FACTORY RESET function of SERVICE item in OPTION menu ( 59) can reset all settings (except LANGUAGE, FILTER TIME, LAMP TIME, FILTER MESSAGE and SECURITY settings and etc.) to the factory default. Be sure to set ALTITUDE after resetting all the settings ( 57). Phenomena that may be easy to be mistaken for machine defects About the phenomenon confused with a machine defect, check and cope with it according to the following table. Phenomenon Cases not involving a machine defectReference page Power does not come on. The electrical power cord is not plugged in. Correctly connect the power cord. 14 The main power source has been interrupted during operation such as by a power outage (blackout), etc. Please disconnect the power plug from the power outlet, and allow the projector to cool down at least 10 minutes, then turn the power on again. 14 Either there is no lamp and/or lamp cover, or either of these has not been properly fixed. Please turn the power off and disconnect the power plug from the power outlet, and allow the projector to cool down at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again. 65 Neither soundsnor pictures areoutputted. The signal cables are not correctly connected. Correctly connect the connection cables. 12, 13 Signal source does not correctly work. Correctly set up the signal source device by referring to the manual of the source device. – The input changeover settings are mismatched. Select the input signal, and correct the settings.21, 22 The BLANK function for pictures and the MUTE function for sounds are working. AV MUTE may be active. Refer to the item “Sound does not come out” and “No pictures are displayed” on the next page to turn off the MUTE and BLANK functions. 20, 28 (continued on next page)
![](/img/blank.gif)
76 Troubleshooting Phenomena that may be easy to be mistaken for machine defects (continue\ d) PhenomenonCases not involving a machine defectReference page Sound does not come out. The signal cables are not correctly connected. Correctly connect the audio cables. 12, 13 The MUTE function is working. Restore the sound pressing MUTE or VOLUME +/- button on the remote control. 20 The volume is adjusted to an extremely low level. Adjust the volume to a higher level using the menu function or the remote control. 20, 46 The AUDIO SOURCE/SPEAKER setting is not correct. Correctly set the AUDIO SOURCE/SPEAKER in AUDIO menu.46 No pictures are displayed. The signal cables are not correctly connected. Correctly connect the connection cables. 12, 13 The brightness is adjusted to an extremely low level. Adjust BRIGHTNESS to a higher level using the menu function.33 The computer cannot detect the projector as a Plug- and-Play monitor. Make sure that the computer can detect a Plug-and-Play monitor using another Plug-and-Play monitor. 11 The BLANK screen is displayed. Press BLANK button on the remote control.28 (continued on next page)
![](/img/blank.gif)
77 PhenomenonCases not involving a machine defectReference page Video screen display freezes. The FREEZE function is working. Press FREEZE button to restore the screen to normal.28 Colors have a faded- out appearance, or Color tone is poor. Color settings are not correctly adjusted. Perform picture adjustments by changing the COLOR TEMP, COLOR, TINT and/or COLOR SPACE settings, using the menu functions.34, 39 COLOR SPACE setting is not suitable. Change the COLOR SPACE setting to AUTO, RGB, SMPTE240, REC709 or REC601. 39 Pictures appear dark. The brightness and/or contrast are adjusted to an extremely low level. Adjust BRIGHTNESS and/or CONTRAST settings to a higher level using the menu function. 33 The projector is operating in Eco mode. Set ECO MODE to NORMAL, and set AUTO ECO MODE to OFF, in the SETUP menu.43, 44 The lamp is approaching the end of its product lifetime. Replace the lamp. 65, 66 Pictures appear blurry. Either the focus and/or horizontal phase settings are not properly adjusted. Adjust the focus using the focus ring, and/or H PHASE using the menu function. 24, 38 The lens is dirty or misty. Clean the lens referring to the section Caring for the lens. 69 (continued on next page) Troubleshooting Phenomena that may be easy to be mistaken for machine defects (continue\ d)
![](/img/blank.gif)
78 PhenomenonCases not involving a machine defectReference page Some kind of image degradation such as flickering or stripes appear on screen. When the projector is operating in Eco mode, flickering may appear on screen. Set ECO MODE to NORMAL, and set AUTO ECO MODE to OFF, in the SETUP menu. 43, 44 The OVER SCAN ratio is too big. Adjust OVER SCAN in the IMAGE menu smaller.37 Excessive VIDEO NR. Change the setting of VIDEO NR in the INPUT menu.39 The FRAME LOCK function cannot work on the current input signal. Set FRAME LOCK in the INPUT menu to OFF. 41 RS-232C does not work. The SAVING function is working. Select NORMAL for STANDBY MODE item in the SETUP menu.45 Troubleshooting Phenomena that may be easy to be mistaken for machine defects (continue\ d) • Although bright spots or dark spots may appear on the screen, this is a unique characteristic of liquid crystal displays, and it does not constitute or imply a machine defect. NOTE
![](/img/blank.gif)
79 Specifications Specifications Please see the Specifications in the User’s Manual (concise) which is a book. End User License Agreement for the Projector Software • Software in the projector consists of the plural number of independent software modules and there exist our copyright or/and third party copyrights for each of such software modules. • Be sure to read “End User License Agreement for the Projector Software” which is separated document. DUKANE CORP AV SERVICE DEPT 2900 Dukane Drive St Charles, IL 60174 800-676-2487 / 630-762-4032 Fax 630-584-5156 [email protected] www.dukane.com/av