Page 111
111 Maintenance Cleaning and replacing the air filter (continued) 9.Turn the projector on and reset the filter time using the FILTER TIME item in the EASY MENU. ►Before taking care of the air filter, make sure the power cable is not plugged in, then allow the projector to cool sufficiently. Taking care of the air filter in a high temperature state of the projector could cause an electric shock, a burn or malfunction to the projector. ►Use only the air filter of the specified type. Do not use the...
Page 112
112 Maintenance Other care In order to ensure the safe use of your projector, please have it cleaned and inspected by your dealer about once every year. 1.Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. 2.After making sure that the projector is cool adequately, lightly wipe the lens with a commercially available lens-cleaning wipe. Do not touch the lens directly with your hand. If the lens is flawed, soiled or fogged, it could cause deterioration of...
Page 113
113 Troubleshooting Troubleshooting If an abnormal operation should occur, stop using the projector immediately. Otherwise if a problem occurs with the projector, the following checks and measures are recommended before requesting repair. If this does not resolve the problem, please contact your dealer or service company. They will tell you what warranty condition is applied. ►Never use the projector if abnormal operations such as smoke, strange odor, excessive sound, damaged casing or elements or...
Page 114
114 MessageDescription The internal temperature is rising. Please turn the power off, and allow the projector to cool down at least 20 minutes. After having confirmed the following items, please turn the power ON again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 35°C? • If the projector is used at an altitude of about 1600 m (5250 feet) or higher, set ALTITUDE of the SERVICE item in the OPTION menu to HIGH ( 59) ....
Page 115
115 Troubleshooting Regarding the indicator lamps When operation of the LAMP, TEMP and POWER indicators differs from usual, check and cope with it according to the following table. POWER indicator LAMP indicator TEMP indicator Description Lighting In Orange Turned off Turned off The projector is in a standby state.Please refer to the section “Power on/off”. Blinking In Green Turned off Turned off The projector is warming up.Please wait. Lighting In Green Turned off Turned off The projector is in an...
Page 116
116 Troubleshooting Regarding the indicator lamps (continued) POWER indicator LAMP indicator TEMP indicator Description Blinking In Red or Lighting In Red Turned off Blinking In Red The cooling fan is not operating.Please turn the power off, and allow the projector to cool down at least 20 minutes. After the projector has sufficiently cooled down, please make confirmation that no foreign matter has become caught in the fan, etc., and then turn the power on again. If the same indication is...
Page 117
117 • When the interior portion has become overheated, for safety purposes, the projector is automatically shut down, and the indicator lamps may also be turned off. In such a case, disconnect the power cord, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again. If the projector is used at an altitude of about 1600 m (5250 feet) or higher, set ALTITUDE of the...
Page 118
118 Troubleshooting Resetting all settings When it is hard to correct some wrong settings, the FACTORY RESET function of SERVICE item in OPTION menu ( 66) can reset all settings (except settings such as LANGUAGE, LAMP TIME, FILTER TIME, FILTER MESSAGE, SECURITY and NETWORK) to the factory default. Be sure to set ALTITUDE after resetting all the settings ( 59) . Phenomena that may be easy to be mistaken for machine defects About the phenomenon confused with a machine defect, check and cope with it...
Page 119
119 Troubleshooting Phenomena that may be easy to be mistaken for machine defects (continue\ d) PhenomenonCases not involving a machine defectReference page Sound does not come out. The signal cables are not correctly connected. Correctly connect the audio cables. 12 ~ 15 The MUTE function is working. Restore the sound pressing MUTE or VOLUME +/- button on the remote control. 23 The volume is adjusted to an extremely low level. Adjust the volume to a higher level using the menu function or the...
Page 120
120 PhenomenonCases not involving a machine defectReference page No pictures are displayed. (continued) The projector does not recognize the USB storage device inserted into USB TYPE A port. Before removing the USB storage device, be sure to use the REMOVE USB function on the thumbnail screen, which appears when the USB TYPE A port is selected as the input source.13, 87 Video screen display freezes. The FREEZE function is working. Press FREEZE button to restore the screen to normal.31 Colors have...