Digital Projection E-Vision 8000 series THE OPERATION COMMANDS Remote Communications Guide Page Rem_6 ...continued from previous page Notes LAMPS menu lamps= ?0 = Single 1 = Dual Not applicable when lamp is cooling. lamp.mode= ?0 = Economy 1 = Standard 2 = Dimming Drive Not applicable without signal locked. lamp.pwr= ?0 ~ 25 ( 80.4 % ~ 100.0 % )Not applicable without signal locked. altitude= ?0 = Off 1 = On High Altitude lamp1.stat?0 = Off 1 = On lamp2.stat?0 = Off 1 = On ALIGNMENT menu proj.mode= ?0 = Front 1 = Rear 2 = Ceiling + Front 3 = Ceiling + Rear fan.pos= ?0 = Normal 1 = Vertical 2 = Down zoomio+ -+ = Zoom out - = Zoom in focus+ -+ = Focus Near - = Focus Far vert.offset+ -+ = Up - = Down Vertical Lens Shift horiz.offset+ -+ = Right - = Left Horizontal Lens Shift lens.load=1 ~ 10Lens Memory Load lens.save=1 ~ 10Lens Memory Save lens.center(execute) continued on next page... Notes Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series THE OPERATION COMMANDS Remote Communications Guide Page Rem_7 ...continued from previous page Notes h.keystone= ? + --350 ~ +350The sum of the absolute values of h.keystone and v.keystone cannot be greater than 350. v.keystone= ? + --200 ~ +200The sum of the absolute values of h.keystone and v.keystone cannot be greater than 350. warp.rotat= ? + --20 ~ +20Each unit is ¼°. warp.pinbrl= ? + --100 ~ +100Pincushion/Barrel warp.tlc.x warp.tlc.y = ? + -x: -192 ~ +192 y: -120 ~ +120 Top Left Corner warp.trc.x warp.trc.y = ? + -x: -192 ~ +192 y: -120 ~ +120 Top Right Corner warp.blc.x warp.blc.y = ? + -x: -192 ~ +192 y: -120 ~ +120 Bottom Left Corner warp.brc.x warp.brc.y = ? + -x: -192 ~ +192 y: -120 ~ +120 Bottom Right Corner warp.reset(execute) blank.top= ? + -0 ~ 360 blank.btm= ? + -0 ~ 360 blank.left= ? + -0 ~ 534 blank.right= ? + -0 ~ 534 blank.rst(execute) eb.stat= ?0 = Off 1 = On Edge Blend eb.wht.top= ? + -0, 200 ~ 500Blend Width Top 1-199 not allowed eb.wht.btm= ? + -0, 200 ~ 500Blend Width Bottom 1-199 not allowed eb.wht.left= ? + -0, 200 ~ 800Blend Width Left 1-199 not allowed eb.wht.right= ? + -0, 200 ~ 800Blend Width Right 1-199 not allowed eb.blk.top= ? + -0, 8, 16, 24, 32Black Level Uplift Area Top continued on next page... Notes Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series THE OPERATION COMMANDS Remote Communications Guide Page Rem_8 ...continued from previous page Notes eb.blk.btm= ? + -0, 8, 16, 24, 32Black Level Uplift Area Bottom eb.blk.left= ? + -0, 4, 8, 12, 16, 20, 24, 28, 32Black Level Uplift Area Left eb.blk.right= ? + -0, 4, 8, 12, 16, 20, 24, 28, 32Black Level Uplift Area Right eb.all= ? + -0 ~ 32Black Level Uplift Adjust Width All eb.red= ? + -0 ~ 32Black Level Uplift Adjust Width Red eb.green= ? + -0 ~ 32Black Level Uplift Adjust Width Green eb.blue= ? + -0 ~ 32Black Level Uplift Adjust Width Blue eb.reset(execute) eb.adl= ?0 = Off 1 = On Align Pattern CONTROL menu eco.net.pow= ?0 = Off (ECO Standby Mode) 1 = On (Standard Standby Mode) Eco Network Power auto.powoff= ?0 = Off 1 = On auto.powon= ?0 = Off 1 = On proj.ctrl= ?0 = RS232 1 = network Not applicable when Eco Network Power is on. net.ipaddr= ? net.subnet= ? net.gateway= ? net.dhcp= ?0 = Off 1 = On startup.logo= ?0 = Off 1 = On continued on next page... Notes Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series THE OPERATION COMMANDS Remote Communications Guide Page Rem_9 ...continued from previous page Notes trig.1= ?0 = 5:4 1 = 4:3 2 = 16:10 3 = 16:9 4 = 1.88 5 = 2.35 6 = Letterbox 7 = Native 8 = Unscaled 9 = Auto If trig.1 is set to Auto, the projector will start sending the trigger as soon as it is switched on. Otherwise the trigger will be sent only when the aspect ratio matches this setting. auto.src= ?0 = Off 1 = On Auto Search dblack= ?0 = Off 1 = On Dynamic Black lang= ?0 = English 1 = French 2 = Spanish 3 = German 4 = Portuguese 5 = Chinese Simplified 6 = Chinese Traditional 7 = Japanese 8 = Korean SERVICE menu model? ser.no? sw.ver? act.src?0 = HDMI 1 = DVI 2 = VGA 3 = Component / BNC 4 = Composite 5 = S-Video 6 = 3G-SDI Active Source continued on next page... Notes Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series THE OPERATION COMMANDS Remote Communications Guide Page Rem_10 ...continued from previous page Notes pip.src?0 = HDMI 1 = DVI 2 = VGA 3 = Component / BNC 4 = Composite 5 = S-Video 6 = 3G-SDI PIP Source pixel.clock?In MHz Not applicable without signal locked. signal?Not applicable without signal locked. h.refresh?Not applicable without signal locked. v.refresh?Not applicable without signal locked. lamp1.hours? lamp2.hours? proj.runtime? blue.only= ?0 = Off 1 = On fact.reset(execute)Factory reset Miscellaneous commands power.on(execute)Power on power.off(execute)Power off (puts projector into Standby mode) picture.mute= ?0 = Off 1 = On status?0 = standby 1 = warm up 2 = imaging 3 = cooling 4 = warning remote.set= ?1 ~ 10: Set Projector ID 255: Clear Projector ID (No ID) Notes Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series THE KEY COMMANDS Remote Communications Guide Page Rem_11 The Key Commands Corresponding remote control key power.onPOWER ON power.offPOWER OFF menuMENU exitEXIT inputINPUT picturePICTURE networkNETWORK autosyncAUTO SYNC aspectASPECT pipPIP overscanOVERSCAN freezeFREEZE lampmodeLAMP MODE infoINFO shutterSHUTTER idsetID SET lensshiftLENS SHIFT testpatternTEST PATTERN enterENTER upUP downDOWN leftLEFT rightRIGHT Notes An input command will return “NA” when the input command is not applicable in some specific conditions. Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series WEB CONFIGURATION UTILITY Remote Communications Guide Page Rem_12 Web Configuration Utility The LAN IP Address of the projector can be set remotely using the Web Configuration Utility. • Make sure the projector is connected to a remote computer via LAN. • From the remote computer, access the default LAN IP address of the projector. The Web Configuration Utility opens. It is possible to control many of the projector’s settings using the embedded Web Configuration Utility. The following pages contain a few examples of such settings. Examples Navigate to the Control tab and edit the settings as required. The Source/general page enables you to: • switch the projector on and off • open and close the shutter • select an input source Notes Eco Network Power must be set to Standard, if you wish to control the projector via the LAN connection. The default LAN IP address is 192.168.0.100 If you suspect this has been changed, then you can view the current Network settings in the Control Menu. For more information about connecting the projector via LAN, see the Connection Guide. Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series WEB CONFIGURATION UTILITY Remote Communications Guide Page Rem_13 Examples - continued from previous page The Image settings page allows access to settings from the Picture menu. The Lens adjustments page allows access to lens control settings. Notes Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series WEB CONFIGURATION UTILITY Remote Communications Guide Page Rem_14 Examples - continued from previous page The Geometry adjust and Edge Blend pages allow access to settings from the Alignment menu. Notes Rev B September 2012
![](/img/blank.gif)
Digital Projection E-Vision 8000 series WEB CONFIGURATION UTILITY Remote Communications Guide Page Rem_15 Examples - continued from previous page The Advanced control page allows access to settings from the Picture menu, Color sub-menu. To view and edit your network settings, navigate to the Configuration tab. Notes Rev B September 2012