    							Error CodeMessage Information2. Turn off the system and remove input power for one minute. 
    3. Ensure the processor is seated correctly.
    4. Reapply input power and turn on the system.
    5.  If the issue persists, see Getting Help.
    CPU0702MessageCPU bus parity error detected.
    LCD MessageCPU bus parity error detected. Power cycle system.
    DetailsSystem event log and operating system logs may indicate that the 
    exception is external to the processor.
    Action1.Check system and operating system logs for exceptions. If no  exceptions are found, continue. 
    2. Turn off the system and remove input power for one minute. 
    3. Ensure the processor is seated correctly.
    4. Reapply input power and turn on the system.
    5.  If the issue persists, see Getting Help.
    CPU0703MessageCPU bus initialization error detected.
    LCD MessageCPU bus initialization error detected. Power cycle system.
    DetailsSystem event log and operating system logs may indicate that the 
    exception is external to the processor.
    Action1.Check system and operating system logs for exceptions. If no  exceptions are found, continue. 
    2. Turn off the system and remove input power for one minute. 
    3. Ensure the processor is seated correctly.
    4. Reapply input power and turn on the system.
    5.  If the issue persists, see Getting Help.
    CPU0704MessageCPU  machine check error detected.
    LCD MessageCPU  machine check error detected. Power cycle system.
    DetailsSystem event log and operating system logs may indicate that the 
    exception is external to the processor.
    Action1.Check system and operating system logs for exceptions. If no 
    exceptions are found, continue. 
    2. Turn off the system and remove input power for one minute. 
    3. Ensure the processor is seated correctly.
    4. Reapply input power and turn on the system.
    131 
    						
    							Error CodeMessage Information5.  If the issue persists, see Getting Help.FAN0000MessageFan  RPM is less than the lower warning threshold.
    DetailsFan operating speed is out of range.
    ActionRemove and reinstall the fan. If the issue persists, see Getting Help.
    FAN0001MessageFan  RPM is less than the lower critical threshold.
    LCD MessageFan  RPM is outside of range. Check fan.
    DetailsFan operating speed is out of range.
    ActionRemove and reinstall the fan. If the issue persists, see Getting Help.
    FAN1201MessageFan redundancy is lost.
    LCD MessageFan redundancy is lost. Check fans.
    DetailsFan has failed.
    ActionRemove and reinstall failed fans or install additional fans.
    HWC1001MessageThe  is absent.
    LCD MessageThe  is absent. Check hardware.
    DetailsThe absent device may be necessary for proper operation. System 
    functionality may be degraded.
    ActionReinstall or reconnect the hardware.
    HWC2003MessageThe storage  cable is not connected, or is improperly 
    connected.
    LCD MessageStorage  cable or interconnect failure. Check connection.
    DetailsThe cable may be necessary for proper operation. System 
    functionality may be degraded.
    ActionCheck if the cable is present, then reinstall or reconnect.
    HWC2005MessageThe system board  cable is not connected, or is improperly 
    connected.
    LCD MessageSystem board  cable connection failure. Check connection.
    DetailsThe cable may be necessary for proper operation. System 
    functionality may be degraded.
    132 
    						
    							Error CodeMessage InformationActionCheck if the cable is present, then reinstall or reconnect.MEM0000MessagePersistent correctable memory errors detected on a memory device at location(s) <
    location>.
    DetailsThis is an early indicator of a possible future uncorrectable error.
    ActionRe-seat the memory modules. If the issue persists, see Getting Help .
    MEM0001MessageMulti-bit memory errors detected on a memory device at location(s) 
    <
    location>.
    LCD MessageMulti-bit memory error on . Re-seat memory.
    DetailsThe memory module has encountered an uncorrectable error. System  performance may be degraded. The operating system and/or  applications may fail as a result.
    ActionRe-seat the memory modules. If the issue persists, see Getting Help.
    MEM0007MessageUnsupported memory configuration; check memory device at location 
    <
    location>.
    LCD MessageUnsupported memory configuration. Check memory .
    DetailsThe memory may not be seated correctly, misconfigured, or has 
    failed. Memory size is reduced.
    ActionCheck the memory configuration. Re-seat the memory modules. If the 
    issue persists, see 
    Getting Help.
    MEM0701MessageCorrectable memory error rate exceeded for .
    DetailsThe memory may not be operational. This an early indicator of a  possible future uncorrectable error.
    ActionRe-seat the memory modules. If the issue persists, see Getting Help.
    MEM0702MessageCorrectable memory error rate exceeded for .
    LCD MessageCorrectable memory error rate exceeded for . Re-seat 
    memory.
    DetailsThe memory may not be operational. This an early indicator of a 
    possible future uncorrectable error.
    ActionRe-seat the memory modules. If the issue persists, see Getting Help.
    MEM1205MessageMemory mirror redundancy is lost. Check memory device at 
    location(s) <
    location>.
    133 
    						
    							Error CodeMessage InformationLCD MessageMemory mirror lost on . Power cycle system.
    DetailsThe memory may not be seated correctly, misconfigured, or has 
    failed.
    ActionCheck the memory configuration. Re-seat the memory modules. If the 
    issue persists, see 
    Getting Help.
    MEM1208MessageMemory spare redundancy is lost. Check memory device at location 
    <
    location>.
    LCD MessageMemory spare lost on . Power cycle system.
    DetailsMemory sparing is no longer available.
    ActionRe-seat the memory modules. If the issue persists, see Getting Help.
    MEM8000MessageCorrectable memory error logging disabled for a memory device at 
    location <
    location>.
    LCD MessageSBE log disabled on . Re-seat memory.
    DetailsErrors are being corrected but no longer logged.
    ActionReview system logs for memory exceptions. Reinstall memory at 
    location <
    location>.
    PCI1302MessageA bus time-out was detected on a component at bus  
    device<
    device> function .
    DetailsSystem performance may be degraded. The device has failed to  respond to a transaction.
    ActionCycle input power, update component drivers, if device is removable, 
    reinstall the device.
    PCI1304MessageAn I/O channel check error was detected.
    LCD MessageI/O channel check error detected. Power cycle system.
    ActionCycle input power, update component drivers, if device is removable, 
    reinstall the device.
    PCI1308MessageA PCI parity error was detected on a component at bus 
    <
    bus>devicefunction .
    LCD MessagePCI parity error on bus  device  function . 
    Power cycle system.
    DetailsSystem performance may be degraded, PCI device may fail to 
    operate, or system may fail to operate.
    134 
    						
    							Error CodeMessage InformationActionCycle input power, update component drivers, if device is removable, reinstall the device.PCI1320MessageA bus fatal error was detected on a component at bus 
    <
    bus>devicefunction .
    LCD MessageBus fatal error on bus  device  function . Power 
    cycle system.
    DetailsSystem performance may be degraded, or system may fail to operate.
    ActionCycle input power, update component drivers, if device is removable,  reinstall the device.
    PCI1342MessageA bus time-out was detected on a component at slot .
    DetailsSystem performance may be degraded, or system may fail to operate.
    ActionCycle input power, update component drivers, if device is removable, 
    reinstall the device.
    PCI1348MessageA PCI parity error was detected on a component at slot .
    LCD MessagePCI parity error on slot . Re-seat PCI card.
    DetailsSystem performance may be degraded, or system may fail to operate.
    ActionCycle input power, update component drivers, if device is removable, 
    reinstall the device.
    PCI1360MessageA bus fatal error was detected on a component at slot .
    LCD MessageBus fatal error on slot . Re-seat PCI card.
    DetailsSystem performance may be degraded, or system may fail to operate.
    ActionCycle input power, update component drivers, if device is removable, 
    reinstall the device.
    PDR0001MessageFault detected on drive .
    LCD MessageFault detected on drive . Check drive.
    DetailsThe controller detected a failure on the disk and has taken the disk 
    offline.
    ActionRemove and re-seat the failed disk. If the issue persists, see Getting 
    Help.
    PDR1016MessageDrive  is removed from disk drive bay .
    135 
    						
    							Error CodeMessage InformationLCD MessageDrive  removed from disk drive bay . Check drive.
    DetailsThe controller detected that the drive was removed.  
    ActionVerify drive installation. Re-seat the failed drive. If the issue persists, 
    see 
    Getting Help.
    PST0128MessageNo memory is detected.
    LCD MessageNo memory is detected. Inspect memory devices.
    DetailsSystem BIOS was unable to detect memory in the system.
    ActionRe-seat the memory modules. If the issue persists, see Getting Help.
    PST0129MessageMemory is detected, but is not configurable.
    LCD MessageMemory is detected, but is not configurable. Check memory devices.
    DetailsSystem BIOS detected memory, but was unable to configure the 
    memory for system operation.
    ActionCompare system memory installation to supported system memory  configurations.
    PSU0001MessagePower supply  failed.
    LCD MessagePSU  failed. Check PSU.
    ActionRemove and reinstall the power supply. If the issue persists, see 
    Getting Help.
    PSU0002MessageA predictive failure detected on power supply .
    LCD MessagePredictive failure on PSU . Check PSU.
    DetailsSystem performance and power redundancy may be degraded or 
    lost.  
    ActionRemove and reinstall the power supply at the next service window. If 
    the issue persists, see 
    Getting Help.
    PSU0003MessageThe power input for power supply  is lost.
    LCD MessagePower input for PSU  is lost. Check PSU cables.
    DetailsThe power supply is installed correctly but an input source is not  connected or is not functional.  
    ActionVerify the input source is attached to the power supply. Verify the 
    input power is within the operating requirements for the power 
    supply.   
    136 
    						
    							Error CodeMessage InformationPSU0006MessagePower supply  type mismatch.
    LCD MessagePower supply  is incorrectly configured. Check PSU.
    DetailsPower supplies should be of the same input type and power rating.
    ActionInstall matched power supplies and review proper configuration in this manual.
    PSU0016MessagePower supply  is absent.
    LCD MessagePSU  is absent. Check PSU.
    DetailsThe power supply has been removed or has failed.
    Action1.Remove and reinstall the power supply. 
    2.Check cables and subsystem components in the system for 
    damage.
    3.If the issue persists, see Getting Help.
    PSU0031MessageCannot communicate with power supply .
    LCD MessageCannot communicate with PSU . Re-seat PSU.
    DetailsThe power supply may operate, however power supply monitoring is 
    degraded. System performance may be degraded.  
    ActionRemove and reinstall the power supply. If the issue persists, see 
    Getting Help.
    PSU0032MessageThe temperature for power supply  is in a warning range.
    DetailsSystem performance may be degraded.
    ActionCheck the system operating environment, including airflow and inlet 
    temperature. Check system logs for temperature and thermal  component failures.
    PSU0033MessageThe temperature for power supply  is outside of the 
    allowable range.
    LCD MessagePSU  temperature outside of range. Check PSU.
    DetailsSystem performance may be degraded.
    ActionCheck the system operating environment, including airflow and inlet  temperature. Check system logs for temperature and thermal component failures.
    137 
    						
    							Error CodeMessage InformationPSU0034MessageAn under voltage fault detected on power supply .
    LCD MessageAn under voltage fault detected on PSU . Check power 
    source.
    DetailsThis failure may be the result of an electrical issue with cables or 
    subsystem components in the system.
    Action1.Remove and reinstall the power supply. 
    2.Check cables and subsystem components in the system for  damage.
    3.If the issue persists, see Getting Help.
    PSU0035MessageAn over voltage fault detected on power supply .
    LCD MessageOver voltage fault on PSU . Check PSU.
    ActionCheck input power or reinstall the power supply. If the issue persists, 
    see 
    Getting Help.
    PSU0036MessageAn over current fault detected on power supply .
    LCD MessageAn over current fault detected on PSU . Check PSU.
    DetailsThis failure may be the result of an electrical issue with cables or 
    subsystem components in the system.
    Action1.Remove and reinstall the power supply. 
    2.Check cables and subsystem components in the system for 
    damage.
    3.If the issue persists, see Getting Help.
    PSU0037MessageFan failure detected on power supply .
    LCD MessageFan failure detected on PSU . Check PSU.
    ActionCheck for fan blockage. If the problem persists, see Getting Help.
    PSU0076MessageA power supply wattage mismatch is detected; power supply 
    <
    number> is rated for  watts.
    LCD MessagePSU wattage mismatch; PSU  = watts
    DetailsPower supplies should be of the same input type and power rating.
    ActionInstall matched power supplies and review this manual for proper 
    configuration.
    138 
    						
    							Error CodeMessage InformationPSU1201MessagePower supply redundancy is lost.
    DetailsThe power supply tries to operate in a degraded state. System Performance and power redundancy may be degraded or lost.  
    ActionCheck input power. Reinstall the power supply. If the issue persists, see 
    Getting Help.
    PSU1204MessageThe power supplies are not redundant. Insufficient resources to 
    maintain normal operations.
    LCD MessagePSU redundancy degraded. Check PSU cables.
    DetailsThe current power operational mode is non-redundant because of a 
    power supply exception, a power supply inventory change, or a  system power inventory change.
    ActionCheck the event log for power supply failures. Review system 
    configuration and power consumption.
    PWR1004MessageThe system performance degraded because power capacity has 
    changed.
    DetailsThe system may power down or operate in a performance degraded 
    state.
    ActionCheck the event log for power supply failures. Review system  configuration and power consumption and upgrade or install power 
    supplies accordingly.
    PWR1005MessageThe system performance degraded because the user-defined power 
    capacity has changed.
    DetailsThe user-defined power settings have affected system operation.
    ActionIf unintended, review system configuration changes and power  policy.
    PWR1006MessageThe system halted because system power exceeds capacity.
    LCD MessageSystem power demand exceeds capacity. System halted.
    DetailsThe system halted because system power exceeds capacity.
    ActionReview system configuration, upgrade power supplies or reduce 
    system power consumption.
    RFM1008MessageFailure detected on Removable Flash Media .
    LCD MessageRemovable Flash Media  failed. Check SD Card.
    139 
    						
    							Error CodeMessage InformationDetailsAn error was reported during a SD card read or write.
    ActionReseat the flash media. If the problem persists, see Getting Help.
    RFM1014MessageRemovable Flash Media  is write protected.
    LCD MessageRemovable Flash Media  is write protected. Check SD Card.
    DetailsThe card is write-protected by the physical latch on the SD card. A 
    write-protected card cannot be used.
    ActionIf unintended, remove the media and disable write protection.
    RFM1201MessageInternal Dual SD Module redundancy is lost.
    LCD MessageInternal Dual SD Module redundancy is lost. Check SD Card.
    DetailsEither one or both the SD cards are not functioning properly.
    ActionSee Getting Help.
    RFM2001MessageInternal Dual SD Module  is absent.
    LCD MessageInternal Dual SD Module  is absent. Check SD Card.
    DetailsThe SD card module is not detected or not installed.  
    ActionIf unintended, reinstall the SD module.
    RFM2002MessageInternal Dual SD Module  is offline.
    DetailsThe SD card module is installed but may be improperly installed or  configured incorrectly.
    ActionReinstall the SD module.
    RFM2004MessageFailure detected on Internal Dual SD Module .
    LCD MessageInternal Dual SD Module  failed. Check SD Card.
    DetailsThe SD card module is installed but improperly configured or failed to  initialize.  
    ActionReinstall the SD module and remove and reinstall SD cards.  
    RFM2006MessageInternal Dual SD Module  is write protected.
    DetailsThe module is write-protected.  Changes may not be written to the 
    media.  
    ActionIf unintended, remove the media and disable write protection.
    140 
    						
    All Dell manuals Comments (0)

    Related Manuals for Dell R 420 Manual