Page 51
50 ITEMREMARKNO CHECK POINT Compensation of Weak Refrigeration →Making R-temp cooler 1 * Used when making R-temp. down to compensate for weak refrigeration without changing FCP temp. setting. ▷Cutting of J18 ; down by 1.5 ℃ ▷Cutting of J18, J19 ; down by 3℃ Relay Power Controller 2 * To check normal voltage of each electrical devices to & from Mi-com. ▷Check input & output voltage of MICOM and IC7, 8. Fan Power Controller 3 * To check input & output voltage of Fan Electric Current Fuse 4 * To check when...
Page 52
51 NODISASSEMBLING PROCEDURE NO DISASSEMBLING PROCEDURE 16 38▷Pull forward ice maker.▷Unscrew (3 points) Plate Gear Fixture. ▷Unscrew Fixture of Frame Ice Maker.▷Check if ice dropping motor is normal (OK). 8-6. Ice Maker 1) Disassembling Procedure 27▷Remove 2 screws on top front of ice maker. ▷Remove full ice sensing switch and level switch. 49 ▷Separate Ice Maker Assembly from Frame Ice Maker.▷Remove 2 pin housing from Plate Gear Fixture. 510 ▷Separate Cover I/M (A) from Cover I/M (B) with a (-) screw...
Page 53
52 PARTS HOW TO CHECK CRITERION Ice Dropping Motor 2) How to Check Ice Maker ▷Check resistance value of 2 wires with a Multi Tester. ▷GOOD : RS-360RH-14250 : 6 ~ 14Ω ▷DEFECTIVE : Change the motor. I-Sensor (Ice Sensor) ▷Check resistance value of 2 wires with a Multi Tester.▷GOOD : 4.4 ~ 50kΩ (It depends on surround temp.) ▷DEFECTIVE : Change the sensor. Full Ice Sensing Switch ▷Check resistance value of 2 terminals with a Multi Tester.▷GOOD : ▷DEFECTIVE : Change the switch. Level Switch ▷Check...
Page 54
53 1) Insert a flat tip driver into the left down groove of panel frame and snap it out smoothly. 2) Separate 2 housings of 10P / 7P from Front PCB. (Do not hold only wires to pull out.) 3) Unscrew (7 points) to remove Front PCB. * Follow the reverse order when assembling. ※How to replace Front PCB Change the Main Fuse (AC250V 15A) (In the left side of machine compartment) Start Power cord or Fuse is disconnected ? 1’st power of SMPS is on? Main PCB Fuse is disconnected? Voltage (DC12V/14.5V/5V) on...
Page 55
54 Refer to error display in operation and function Start Change the Comp. Change Fuse. Temp Y N N Y N Y YNY N Change OLP/PTC Change F/C-Motor Change M-PCB Check lead wire Change the Defrost Heater Check ice formation on Eva. And if refrigerant leak is found, repair it. N N YY YN N Defrost Heater : 192W (252 Ω) ※Left-lower side of Evaporator (4thpipe from buttom) OLP/PTC is OK? Does Comp. work? Any Error code on F-PCB? F/C-Motor works OK?F/C-Motor is OK? Wiring connection Is OK? Temp. Fuse Is OK?...
Page 56
55 1) Remove foods. 2) Remove Ice Bucket, shelves and cases in Freezer compartment. (1) Removing and replacing Freezer parts * Remove 2 screws of Ice Maker. * Remove the Housing of Ice Maker AS. (Right side) * Remove 4 screws of Geared Motor. * Remove the Housing of Geared Motor AS. (Center) (2) (3)(4) (5)
Page 57
56 * Remove light cover screws. * Pull down smoothly the bottom of light cover to remove. * Remove the screw of bracket F-Lamp. * Remove the left housing. * Hold the end of F-Fan cover and pull forward slowly.* Remove the screw cap on the F-Louver A with a flat tip driver. Removing and replacing Freezer parts * Pull out smoothly the bracket F-Lamp AS. to remove. * Remove 3 screws of F-Louver A. * Hold the end of F-Louver A and pull forward slowly. * Remove the housing. * Remove the screw of F-Return...
Page 58
57 Removing and replacing Freezer parts F-Louver B Heater Housing D-Sensor Housing 1st : F-Louver B Heater Housing 2nd : None. 3rd : Defrost Heater Housing. Temp. Fuse Defrost Heater D-Sensor Defrost Heater Temp. Fuse Housing
Page 59
58 Reassemble the door. Start Explain not to open doors too frequently. Y N N YRemove the gap. Wipe out dews on the louver surface and run the refrigerator again. Change the louver assembly. Y N Y Y Y N N Make enough distance between heat appliances and refrigerator. Y N N 9-2-2. Ice Formation on F-Louver Dews are formed on the gasket surface inside F compartment ? Gasket has a gap between cabinet ? Door is hanged down ? Door is open and closed too frequently ? Heat appliances are too close to the...
Page 60
59 Change the light bulb. Start Repair the F-door switch. Check the F door switch connection and F-light socket. Y N N Y Change of F LightsChange of F Door Switch * Remove 2 screws of light cover. * Hold the bottom of light cover and pull forward to remove. * Change the light bulb. (AC240V 25W)* Insert a flat tip screw driver Into a gap of door switch to pull forward. * Disconnect the housing and change the switch for a new one.① ② ③① ② 9-2-3. Disconnection / breaking of Freezer Lights Wires Freezer...