Page 71
70 Remarks ●Refrigerant is erupting rapidly from the compressor to circulate pipes, so pipe shaking noise can make to some degree. ●In case compressor vibration is sent to a pipe directly, apply vibration absorber rubbers to welding points of the pipe and comp. or to a much bent point on the pipe. Start Separate the touching pipes, if any. NY Apply cushion material between Comp. base and Tray drip. YN Move or change the points of vibration absorber rubbers on the pipes to reduce the shaking. YN Attach a...
Page 72
71 Door switch is soaked with water or there is water in the switch ? PCB input is OK ? Start Change the door switch. NY Repair any disconnection of wires and defective Door switch. Y Connector insertion to Main PCB is OK ?N Repair the defective connection. Y Door switch itself is OK ?N Change the switch. NY Check it up. Door switch is pushed well ? Y Attach a thin pad on the door liner or change the door assembly. Check if interior light is ON. N 9-5. Door 9-5-1. Door Opening Alarm Continues though...
Page 73
72 10-1. Summary of Heavy Repair * Installation should be conducted in accordance with the standard installation procedure. (Leave space of more than 5 cm from the wall for compressor compartment cooling fan mounted model.) Transportation and installation* Copper brush, Rag, Tool box * Remove flux from the silver weld joints with soft brusher wet rag. (Flux may be the cause of corrosion and leaks.) *Clean tools and store them in a clean tool box or in their place. Compressor compartment and tools...
Page 74
73 1) Nitrogen only should be used when cleaning inside of cycle pipes inside and sealing. 2) Check leakage with an electronic leakage tester. 3) Be sure to use a pipe cutter when cutting pipes. 4) Be careful not the water let intrude into the inside of the cycle. Others.1) Weld under nitrogen atmosphere in order to prevent oxidation inside a pipe. (Nitrogen pressure : 0.1~0.2 kg/cm2.) Nitrogen blowing welding.1) Be sure to replace drier when repairing pipes and injecting refrigerant. Replacement of...
Page 75
74 1) Remove residual refrigerant more than 5 minutes later after turning off the refrigerator. ( If not, compressor oil may leak inside.) 2) Remove retained refrigerant slowly by cutting first high pressure side (drier part) with a nipper and then cut low pressure side. 1. Removal of residual refrigerant.Precautions Items 10-3. Practical Work for Heavy Repair * When replacing a drier: Weld ①and②parts by blowing nitrogen (0.1~0.2kg/cm2) to high pressure side after assembling a drier. * When replacing a...
Page 76
75 * Pipe Connection Connect a red hose to the high pressure side and a blue hose to the low pressure side. * Vacuum Sequence Open ①,②valves and evacuate for 40 minutes. Close valve ①. 3.Vacuum degassing.Precautions Items * Charging sequence 1) Check the amount of refrigerant supplied to each model after completing vacuum degassing. 2) Evacuate bombe with a vacuum pump. 3) Measure the amount of refrigerant charged. - Measure the weight of an evacuated bombe with an electronic scale. - Charge refrigerant...
Page 77
76 Precautions Items 4) Refrigerant Charging Charge refrigerant while operating a compressor as shown above. 5) Pinch a charging pipe with a pinch-off plier after completion of charging. 6) Braze the end of a pinched charging pipe with copper brazer and take a gas leakage test on the welded parts. 4.Refrigerant charging. BombeCompressorEvaporator CondenserDryer Hot Pipe * Take a leakage test on the welded or suspicious area with an electronic leakage tester. 5. Gas-leakage test * Check each pipe is...
Page 78
77 10-5. Brazing Reference Drawings. ▶Welding Point ● ■Copper Welding (Ag 5%)7 Points 3 Points Silver Welding (Ag 35%) Hot Pipe F REvaporator CondenserI-Pipe Accumulator Suction Pipe Dryer Capi-Tube Pipe Suc Conn Pipe Conn B Compressor ▶Flow of Refrigeration Cycle Compressor Pipe Conn. BWire-Con. Pipe Hot PipeDryer Capillary Tube EvaporatorAccumulator Pipe Suction Conn Suction Pipe HighLow
Page 79
78 11-1. Installation Preparation 11. INSTALLATION GUIDE Check if the refrigerator can pass a doorway or enter a door first. Dimensions( including Door Handles) (Width*Depth*Height) 903mm X 734.5mm X 1790mm Find a suitable place to install Sufficient space from refrigerator back to the ※wall for free air ventilation※Avoid direct sunlight. Once the installation place is ready follow the installation instructions. If surround temperature of refrigerator is low (below 10℃)), foods can be frozen or...
Page 80
79 11-2. If the refrigerator can not enter the door Removing Freezer Door 1 ※Remove front bottom cover first, if it is attached. Remove front bottom cover first, Pull out the left collar of the coupling first, then hold the coupling and pull out the left water tube.2Unscrew top hinge cover with a screw driver. Remove the hinge cover.3Turn top hinge bolt counterclockwise . Disconnect the harness wires. 4Lift up the front of hinge to remove. ( After the hinge is removed the door can fall down...