10 DC13V / 1100±100rpm Condenser Fan MotorDC13V / 1950 ±100rpm R-Fan MotorDC13V / 2050 ±100rpm F-Fan Motor E L E C T R I C A L P A R T SDispenser Model Specification ( 220~240V Models only ) Item Basic Model Model Name AC250V , 10A , 77℃ Fuse Temp (Defrost)PBN-38 F-Sensor D-Sensor D E F O R E S T AC220V / 5W - Water Pipe HeaterAC220V / 5W - Dispenser HeaterAC220V / 8W Louver Heater H E A T E R SP201R-7DL / SP201R-7DR (SPF101B-2D / SPF101B-1D)AC230~240V / 25W (2EA) AC230~240V / 25W (2EA) R-Lamp Door...
Page 12
11 4-1. Display 5 43 2 1 Temp indicationMax Medium Max Mid Medium Min Min Temperature Chang 5 43 2 1 Temp indicationMax Medium Max Mid Medium Min Min Temperature Change 1. “FRZ.TEMP” Button 1) Temperature control of Freezer compartment 2) 5 step mode of successive temperature mode. 3) Initial mode by power input : “3” ※Whenever pressing button, setting is repeated in the order of Medium(3) →Medium Max(4) →Max(5) →Min(1) →Medium Min(2). 2. “REF.TEMP” button. 1) Temperature control of Refrigerator...
Page 13
12 1. Display control 2. “FREEZER SET” Button 1) Temperature control of freezer compartment 2) 7 step mode of successive temperature mode. 3) Initial mode by power input : “Medium(-19℃)” ※Whenever pressing button, setting is repeated in the order of Medium (-19℃) →Medium Max 1 (-20℃) →Medium Max 2 (-21℃)→Max (-22℃) →Min (-16℃) →Medium Min 2 (-17℃) →Medium Min 2 (-18℃). INPUTCONTROL OBJECT CONTENTS REMARKS Front PCB button FREEZER SET, REFRIGERATOR SET SUPER FREEZER, SUPER REFRIGERATOR RESET FILTER,...
Page 14
13 CONTENTS REMARKS 4. “REFRIGERATOR SET” button. 1) Temperature control of Refrigerator compartment 2) 5 step mode of successive temperature mode. 3) Initial mode by power input : “Medium (4℃)” ※Whenever pressing button, setting is repeated in the order of Medium (4℃) →Medium Max (3℃) →Max (2℃) →Min (6℃) →Medium Min (5℃). 2℃ 3℃ 4℃ 5℃ 6℃ Temp indicationMax Medium Max Mid Medium Min Min Temperature Change 5. “SUPER REFRIGERATOR” button. When this mode is chosen, the icon (REFRIGERATOR QUICK) is ON. 6....
Page 15
14 1. Defrost Mode INPUTCONTROL OBJECT CONTENTS REMARKS 1. Defrosting Cycle1. Comp 2. F-Fan 3. R-Fan 4. D-Heater Pre-Cool Pause Fan-Delay Heater Defrosting Pre-Cool 1) Time : 50 minutes 2) Comp , F-fan : ON R-fan : Control D-HTR : OFF 3) If F-sensor ≤-27℃, then Pre-Cool becomes. OFF Heater Defrosting 1) Comp, F-fan, R-fan : OFF D-HTR : ON 2) Time limit 30 seconds : Heater is ON regardless of D-sensor temperature right after defrosting start 30 minutes : in case of D1- Error 80 minutes : in normal...
Page 16
15 CONTENTS REMARKS 4. Flow Chart of Defrosting Start Start Comp. operating time is over 24 hours? Total time is over 60 hours? Comp. operating time is over 6 hours? EndDefrosting start Comp. operating time is over 2 hours? Any error ? NO YES NO NO YES Total door open time is over 2 min? YES YES YES YESNO NONO Comp. operating rate is more 85%? NO YES
Page 17
16 1. A/S Defrosting Mode (Heater defrost →Pause →Fan Delay) INPUTCONTROL OBJECT CONTENTS REMARKS 1. Defrosting Cycle 1. Comp 2. F-Fan 3. R-Fan 4. D-Heater Heater Defrosting 1) Comp, F-fan, R-fan : OFF D-HTR : ON 2) Time limit 30 seconds : Heater is ON regardless of D-sensor temperature right after defrosting start 30 minutes : in case of D1-Error 80 minutes : in normal control state 3) If D-sensor ≥13℃, Heater Defrosting is OFF Pause Time : 7 minutes Comp, F-fan, R-fan, Heater etc. : OFF Fan-Delay 1)...
Page 18
17 It is linked with comp. INPUTCONTROL OBJECT CONTENTS REMARKS 1. CompLouver Heater 1. Buzzer sounds if any button of Inner Control is pushed. 2. Buzzer sounds 4 times 3 seconds after initial power input. 3. Buzzer sounds for 3 or 1 times in case of A/S forced defrosting and short (pull down) operation or explanation mode. 4. If door is open, buzzer sounds after every 1 minutes for 5 minutes (Door open alarm) INPUTCONTROL OBJECT CONTENTS REMARKS 1. Control (Inner or F-PCB) buttons 2. Door Switch 3....
Page 19
18 1. Start Open and close “Freezer door switch” 5 times while pushing “FRZ. TEMP” button simultaneously. 2. Control 1) All other electrical components are OFF except for F-fan / R-fan 2) Fan Control Door open →Fan ON / Door close →Fan OFF. 3) Display control “FRZ. LED” and “REF. LED” are ON in good order 3. Stop 1) During Demo mode, push “Freezer door switch” open and close 5 times while pushing “FRZ. TEMP” button simultaneously. 2) Power in again INPUTCONTROL OBJECT CONTENTS REMARKS 1. FRZ. TEMP 2....
Page 20
19 Compensation of R-sensor ON/OFF temp. (down) In case temperature of refrigerator compartment is weak or insufficient, take the following action. INPUTCONTROL OBJECT CONTENTS REMARKS Main PCBResistance of R-sensor Mid ON/OFF Point R36 : R-SENSOR standard resistance in normal mode (31.4K) R37 : In case of weak ref., cut J1 (or J18) to down the standard resistance by 1.5deg(2K) R38 : In case of weak ref., cut J2 (or J19) to down the standard resistance by 1.5deg(2K) 4-9. Compensation of R-sensor ON/OFF...